Search results for " Biomedical"
showing 10 items of 480 documents
An Information-Theoretic Framework to Map the Spatiotemporal Dynamics of the Scalp Electroencephalogram
2016
We present the first application of the emerging framework of information dynamics to the characterization of the electroencephalography (EEG) activity. The framework provides entropy-based measures of information storage (self entropy, SE) and information transfer (joint transfer entropy (TE) and partial TE), which are applied here to detect complex dynamics of individual EEG sensors and causal interactions between different sensors. The measures are implemented according to a model-free and fully multivariate formulation of the framework, allowing the detection of nonlinear dynamics and direct links. Moreover, to deal with the issue of volume conduction, a compensation for instantaneous e…
Instantaneous Transfer Entropy for the Study of Cardiovascular and Cardio-Respiratory Nonstationary Dynamics
2017
Objective: Measures of transfer entropy (TE) quantify the direction and strength of coupling between two complex systems. Standard approaches assume stationarity of the observations, and therefore are unable to track time-varying changes in nonlinear information transfer with high temporal resolution. In this study, we aim to define and validate novel instantaneous measures of TE to provide an improved assessment of complex nonstationary cardiorespiratory interactions. Methods: We here propose a novel instantaneous point-process TE (ipTE) and validate its assessment as applied to cardiovascular and cardiorespiratory dynamics. In particular, heartbeat and respiratory dynamics are characteriz…
Information transfer in QT-RR dynamics: Application to QT-correction
2018
ABSTRACTThe relation between the electrical properties of the heart and the beating rate is essential for the heart functioning. This relation is central when calculating the “corrected QT interval” — an important measure of the risk of potentially lethal arrhythmias. We use the transfer entropy method from information theory to quantitatively study the mutual dynamics of the ventricular action potential duration (the QT interval) and the length of the beat-to-beat (RR) interval. We show that for healthy individuals there is a strong asymmetry in the information transfer: the information flow from RR to QT dominates over the opposite flow (from QT to RR), i.e. QT depends on RR to a larger e…
Relationship between foot eversion and thermographic foot skin temperature after running.
2017
The main instruments to assess foot eversion have some limitations (especially for field applications), and therefore it is necessary to explore new methods. The objective was to determine the relationship between foot eversion and skin temperature asymmetry of the foot sole (difference between medial and lateral side), using infrared thermography. Twenty-two runners performed a running test lasting 30 min. Skin temperature of the feet soles was measured by infrared thermography before and after running. Foot eversion during running was measured by kinematic analysis. Immediately after running, weak negative correlations were observed between thermal symmetry of the rearfoot and eversion at…
Effects of prefabricated and custom-made foot orthoses on skin temperature of the foot soles after running
2019
OBJECTIVE Foot orthoses are increasingly used by runners despite the controversy about whether their use can reduce the risk of overuse injuries. Some authors have found modifications in plantar pressures with the use of foot orthoses, which could produce changes in the surface skin temperature of the foot soles. The aim of this study was to analyse the effects of custom-made and prefabricated foot orthoses on the skin temperature of different regions of both foot soles after running. APPROACH Twenty-four participants carried out a maximal aerobic speed test as a pre-test, and three running tests at the laboratory wearing different foot orthoses conditions (control, prefabricated and custom…
Influence of dental occlusion conditions on plantar pressure distribution during standing and walking – A gender perspective
2021
Abstract The aim of this study was to investigate gender-specific influences of different symmetric and asymmetric occlusion conditions on postural control during standing and walking. The study involved 59 healthy adult volunteers (41 f/19 m) aged between 22 and 53 years (30.2 ± 6.3 years). Postural control measurements were carried out using a pressure plate by measuring plantar pressure distribution during standing and walking test conditions. Seven different occlusion conditions were tested. Prior to a MANOVA model analysis, the relationship between the two test conditions were checked using a factor analysis with a varying number of factors (between 2 and 10). The plantar pressure dist…
3D-printing-assisted fabrication of chitosan scaffolds from different sources and cross-linkers for dental tissue engineering
2021
The aim of the present study was to fabricate and characterise chitosan scaffolds from animal and fungal sources, with or without gelatine as a co-polymer, and cross-linked to 3-glycidyloxyproply trimethoxysilane (GPTMS) or genipin for application in dental root tissue engineering. Chitosan-based scaffolds were prepared by the emulsion freeze-drying technique. Scanning electron microscopy (SEM) and nano-focus computed tomography (nano-CT) were used to characterise scaffold microstructure. Chemical composition and cross-linking were evaluated by Fourier transform infrared-attenuated total reflectance spectroscopy. Compression tests were performed to evaluate scaffold mechanical properties. S…
Autologous Iliac Bone Graft Compared with Biphasic Hydroxyapatite and Calcium Sulfate Cement for the Treatment of Bone Defects in Tibial Plateau Frac…
2019
Background Bone-graft substitutes are commonly used for the augmentation of traumatic bone defects in tibial plateau fractures. However, their clinical performance compared with that of autologous bone-grafting, the gold standard in bone defect reconstruction, still remains under debate. This study investigates the differences in quality of life, pain, and radiographic outcomes in the treatment of tibial plateau fracture-associated bone defects with either autologous bone grafts or a bioresorbable hydroxyapatite and calcium sulfate cement (CERAMENT BONE VOID FILLER [CBVF]; BONESUPPORT). Methods In this study, 135 patients with acute depression and split-depression fractures of the proximal …
Neutrophil‐mediated enhancement of angiogenesis and osteogenesis in a novel triple cell co‐culture model with endothelial cells and osteoblasts
2017
Repair and regeneration of critical‐sized bone defects remain a major challenge in orthopaedic and craniomaxillofacial surgery. Until now, attempts to bioengineer bone tissue have been hindered by the inability to establish proper angiogenesis and osteogenesis in the tissue construct. In the present study, we established a novel triple cell co‐culture model consisting of osteoblasts, endothelial cells, and neutrophils and conducted a systematic investigation of the effects of neutrophils on angiogenesis and osteogenesis. Neutrophils significantly increased angiogenesis in the tissue construct, evidenced by the formation of microvessel‐like structures with an extensive lattice‐like, stable t…
Biceps brachii muscle oxygenation in electrical muscle stimulation
2010
The purpose of this study was to compare between electrical muscle stimulation (EMS) and maximal voluntary (VOL) isometric contractions of the elbow flexors for changes in biceps brachii muscle oxygenation (tissue oxygenation index, TOI) and haemodynamics (total haemoglobin volume, tHb = oxygenated-Hb + deoxygenated-Hb) determined by near-infrared spectroscopy (NIRS). The biceps brachii muscle of 10 healthy men (23-39 years) was electrically stimulated at high frequency (75 Hz) via surface electrodes to evoke 50 intermittent (4-s contraction, 15-s relaxation) isometric contractions at maximum tolerated current level (EMS session). The contralateral arm performed 50 intermittent (4-s contrac…