Search results for " Biomedical"

showing 10 items of 480 documents

Thermo-responsive hydrogels from cellulose-based polyelectrolytes and catanionic vesicles for biomedical application.

2016

In this study, negatively charged catanionic vesicles/hydrophobically modified hydroxyethylcellulose polymers thermo-responsive hydrogels have been fabricated. Vesicular aggregates were found to act as multifunctional junctions for networking of modified-cellulose water solutions. The contributions of the electrostatic and hydrophobic interactions were evaluated by changing either vesicles composition or the polymer hydrophobic substitution. Thermal-induced size and lamellarity of hydrogel-enclosed vesicles were detected, with further polygonal shape changes induced by cellulose-based polymer addition. The thermal transition was also found to tune hydrogel mechanical behaviour. The network …

AnionsProton Magnetic Resonance SpectroscopyBiomedical EngineeringBiomedical TechnologyCeramics and CompositeBiomaterialsDiffusioncatanionic vesicleTheophyllineCationsCellulosecatanionic vesicles; cellulose; diffusion; hydrogel; NMR; rheology; Ceramics and Composites; Biomaterials; Biomedical Engineering; 2506ViscositydiffusionTemperatureHydrogelsBiomaterialPolyelectrolytescelluloseNMRElasticityDrug LiberationSettore CHIM/09 - Farmaceutico Tecnologico Applicativocatanionic vesiclesCeramics and Compositesrheologyhydrogel2506RheologyJournal of biomedical materials research. Part A
researchProduct

Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse

2011

OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…

Aortic archMalemedicine.medical_specialtyAortographymedicine.medical_treatmentHemodynamicsAorta ThoracicFOS: Medical engineeringProsthesis DesignAortographyBlood Vessel Prosthesis ImplantationImaging Three-DimensionalBlood vessel prosthesismedicine.arteryMaterials TestingmedicineHumansComputer Simulationthoracic aortic stent graft (TASG)Aortamedicine.diagnostic_testbusiness.industryEndovascular ProceduresHemodynamicsModels CardiovascularStentSettore ING-IND/34 - Bioingegneria Industrialenutritional and metabolic diseases90399 Biomedical Engineering not elsewhere classifiedCurvatures of the stomachSurgeryBiomechanical PhenomenaBlood Vessel ProsthesisProsthesis FailureEquipment Failure AnalysisRegional Blood FlowRadiographic Image Interpretation Computer-AssistedStentslipids (amino acids peptides and proteins)SurgeryStress Mechanicalbiological phenomena cell phenomena and immunitybusinessNuclear medicineTomography X-Ray ComputedCardiology and Cardiovascular MedicinePerfusionAlgorithmsJournal of Vascular Surgery
researchProduct

Comparison of hemodynamic and structural indices of ascending thoracic aortic aneurysm as predicted by 2-way FSI, CFD rigid wall simulation and patie…

2018

Patient-specific computational modeling is increasingly being used to predict structural and hemodynamic parameters, especially when current clinical tools are not accessible. Indeed, pathophysiology of ascending thoracic aortic aneurysm (ATAA) has been simulated to quantify the risk of complications by novel prognostic parameters and thus to improve the clinical decision-making process related to the intervention of ATAAs. In this study, the relevance of aneurysmal wall elasticity in determining parameters of clinical importance, such as the wall shear stress (WSS), is discussed together with the significance of applying realistic boundary conditions to consider the aortic stretch and twis…

Aortic valveAdultMalePatient-Specific Modelingmedicine.medical_specialtyComputer science0206 medical engineeringFinite Element Analysisaorti failureHeart Valve DiseasesHemodynamicsFluid-solid interaction (FSI)Health Informatics02 engineering and technology030204 cardiovascular system & hematologyComputational fluid dynamicsThoracic aortic aneurysm03 medical and health sciences0302 clinical medicineBicuspid aortic valveBicuspid Aortic Valve DiseaseInternal medicinemedicineShear stressHumansComputer SimulationAgedAortic Aneurysm ThoracicStructural mechanicsbusiness.industryFinite element analysis (FEA)Models CardiovascularMiddle Agedmedicine.diseaseAscending thoracic aortic aneurysm020601 biomedical engineeringFinite element methodElasticityComputer Science Applicationsmedicine.anatomical_structureComputational fluid-dynamic (CFD)Aortic Valvecardiovascular systemCardiologyFemaleStress Mechanicalbusiness
researchProduct

In Silico Shear and Intramural Stresses are Linked to Aortic Valve Morphology in Dilated Ascending Aorta

2017

Objective/Background: The development of ascending aortic dilatation in patients with bicuspid aortic valve (BAV) is highly variable, and this makes surgical decision strategies particularly challenging. The purpose of this study was to identify new predictors, other than the well established aortic size, that may help to stratify the risk of aortic dilatation in BAV patients.Methods: Using fluid-structure interaction analysis, both haemodynamic and structural parameters exerted on the ascending aortic wall of patients with either BAV ( n = 21) or tricuspid aortic valve (TAV; n = 13) with comparable age and aortic diameter (42.7 +/- 5.3 mm for BAV and 45.4 +/- 10.0 mm for TAV) were compared…

Aortic valveMalePatient-Specific ModelingComputed Tomography AngiographyHeart Valve DiseasesHemodynamics02 engineering and technology030204 cardiovascular system & hematology0302 clinical medicineBicuspid aortic valveBicuspid Aortic Valve DiseaseRisk FactorsAortaSinotubular JunctionModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeComputational modelingAneurysm of ascending aortaMiddle AgedAortic AneurysmHeart Valve Diseasemedicine.anatomical_structureAortic Valvecardiovascular systemCardiologyWall shear streFemaleCardiology and Cardiovascular MedicineBlood Flow VelocityDilatation PathologicHumanmedicine.medical_specialtyBicuspid aortic valve0206 medical engineeringAortography03 medical and health sciencesInternal medicinemedicine.arteryAscending aortamedicineHumansAgedAortabusiness.industryRisk FactorSignificant differenceHemodynamicsmedicine.disease020601 biomedical engineeringAortic wallRegional Blood FlowSurgeryStress Mechanicalbusiness
researchProduct

On the Left Ventricular Remodeling of Patients with Stenotic Aortic Valve: A Statistical Shape Analysis

2021

The left ventricle (LV) constantly changes its shape and function as a response to pathological conditions, and this process is known as remodeling. In the presence of aortic stenosis (AS), the degenerative process is not limited to the aortic valve but also involves the remodeling of LV. Statistical shape analysis (SSA) offers a powerful tool for the visualization and quantification of the geometrical and functional patterns of any anatomic changes. In this paper, a SSA method was developed to determine shape descriptors of the LV under different degrees of AS and thus to shed light on the mechanistic link between shape and function. A total of n=86 patients underwent computed tomography (…

Aortic valveTechnologymedicine.medical_specialtyQH301-705.5left ventricle0206 medical engineeringstatistical shape analysisBioengineeringaortic valve stenosis02 engineering and technology030204 cardiovascular system & hematologyArticle03 medical and health sciences0302 clinical medicineInternal medicinemedicineIn patientBiology (General)Settore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeVentricular remodelingbusiness.industryTStatistical shape analysisSettore ING-IND/34 - Bioingegneria IndustrialeBaseline modelmedicine.disease020601 biomedical engineeringStenosismedicine.anatomical_structureAortic valve stenosis Left ventricle Statistical shape analysisVentriclePrincipal component analysisCardiologybusinessBioengineering
researchProduct

Transcatheter Heart Valve Implantation in Bicuspid Patients with Self-Expanding Device

2021

Bicuspid aortic valve (BAV) patients are conventionally not treated by transcathether aortic valve implantation (TAVI) because of anatomic constraint with unfavorable outcome. Patient-specific numerical simulation of TAVI in BAV may predict important clinical insights to assess the conformability of the transcathether heart valves (THV) implanted on the aortic root of members of this challenging patient population. We aimed to develop a computational approach and virtually simulate TAVI in a group of n.6 stenotic BAV patients using the self-expanding Evolut Pro THV. Specifically, the structural mechanics were evaluated by a finite-element model to estimate the deformed THV configuration in …

Aortic valveTechnologymedicine.medical_specialtybicuspid aortic valveQH301-705.5medicine.medical_treatment0206 medical engineeringDiastoleBioengineering02 engineering and technology030204 cardiovascular system & hematologyBicuspid aortic valve Finite-element analysis Fluid–solid interaction Transcatheter aortic valve implantationArticle03 medical and health sciences0302 clinical medicineBicuspid aortic valveInternal medicinemedicine.arterymedicineCardiac skeletonHeart valveBiology (General)transcatheter aortic valve implantationAortabusiness.industryTSettore ING-IND/34 - Bioingegneria IndustrialeStentmedicine.diseasefluid–solid interaction020601 biomedical engineeringAortic wallmedicine.anatomical_structurefinite-element analysiscardiovascular systemCardiologybusinessBioengineering
researchProduct

Deep learning approach for the segmentation of aneurysmal ascending aorta.

2020

Diagnosis of ascending thoracic aortic aneurysm (ATAA) is based on the measurement of the maximum aortic diameter, but size is not a good predictor of the risk of adverse events. There is growing interest in the development of novel image-derived risk strategies to improve patient risk management towards a highly individualized level. In this study, the feasibility and efficacy of deep learning for the automatic segmentation of ATAAs was investigated using UNet, ENet, and ERFNet techniques. Specifically, CT angiography done on 72 patients with ATAAs and different valve morphology (i.e., tricuspid aortic valve, TAV, and bicuspid aortic valve, BAV) were semi-automatically segmented with Mimic…

Aortic valvemedicine.medical_specialtyComputer science0206 medical engineeringBiomedical Engineering02 engineering and technology01 natural sciencesThoracic aortic aneurysm010309 opticsAneurysmBicuspid aortic valvemedicine.artery0103 physical sciencesAscending aortamedicineSegmentationAortabusiness.industryDeep learningSettore ING-IND/34 - Bioingegneria Industrialemedicine.disease020601 biomedical engineeringAneurysm Aorta Aortic valve Deep learningSegmentationmedicine.anatomical_structureOriginal ArticleRadiologyArtificial intelligencebusinessBiomedical engineering letters
researchProduct

Constitutive modeling of ascending thoracic aortic aneurysms using microstructural parameters.

2016

Ascending thoracic aortic aneurysm (ATAA) has been associated with diminished biomechanical strength and disruption in the collagen fiber microarchitecture. Additionally, the congenital bicuspid aortic valve (BAV) leads to a distinct extracellular matrix structure that may be related to ATAA development at an earlier age than degenerative aneurysms arising in patients with the morphological normal tricuspid aortic valve (TAV). The purpose of this study was to model the fiber-reinforced mechanical response of ATAA specimens from patients with either BAV or TAV. This was achieved by combining image-analysis derived parameters of collagen fiber dispersion and alignment with tensile testing dat…

Aortic valvemedicine.medical_specialtyMaterials scienceBicuspid aortic valve0206 medical engineeringFinite Element AnalysisBiomedical EngineeringBiophysics02 engineering and technology030204 cardiovascular system & hematologyThoracic aortic aneurysmModels BiologicalArticleExtracellular matrixSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di Macchine03 medical and health sciencesAortic aneurysmFinite Element Analysi0302 clinical medicineBicuspid aortic valveFinite elementmedicine.arteryInternal medicineTensile StrengthAscending aortamedicineHumansAortaMechanical PhenomenaAortaAortic aneurysmAortic Aneurysm ThoracicSettore ING-IND/34 - Bioingegneria IndustrialeBiomechanical strengthExtracellular matrixAnatomymedicine.disease020601 biomedical engineeringBiomechanical Phenomenamedicine.anatomical_structureBiophysicCardiologycardiovascular systemCollagenStress MechanicalAortic failureHumanMedical engineeringphysics
researchProduct

Statistical shape analysis of ascending thoracic aortic aneurysm: Correlation between shape and biomechanical descriptors

2020

An ascending thoracic aortic aneurysm (ATAA) is a heterogeneous disease showing different patterns of aortic dilatation and valve morphologies, each with distinct clinical course. This study aimed to explore the aortic morphology and the associations between shape and function in a population of ATAA, while further assessing novel risk models of aortic surgery not based on aortic size. Shape variability of n = 106 patients with ATAA and different valve morphologies (i.e., bicuspid versus tricuspid aortic valve) was estimated by statistical shape analysis (SSA) to compute a mean aortic shape and its deformation. Once the computational atlas was built, principal component analysis (PCA) allow…

Aortic valveprincipal component analysis0206 medical engineeringPopulationshape analysislcsh:MedicineMedicine (miscellaneous)Principal component analysi02 engineering and technology030204 cardiovascular system & hematologyThoracic aortic aneurysmTortuosityArticleCorrelation03 medical and health sciences0302 clinical medicinemedicine.arterymedicineShear stress: straineducationeducation.field_of_studyAortaShape analysibusiness.industryStatistical shape analysislcsh:RComputational modelingAnatomymedicine.disease020601 biomedical engineeringmedicine.anatomical_structurecardiovascular systembusinessShape analysis (digital geometry)
researchProduct

Dielectric Behavior of Aqueous Solutions of α,β-Poly(aspartyl hydrazide) and α,β-Poly(N-hydroxyethyl aspartamide): An Investigation of the Structural…

1994

The dielectric properties of aqueous solutions of α,β-poly(aspartyl hydrazide) (PAHy) and of α,β-poly( N-hydroxyethyl aspartamide) (PHEA) were measured at 25 ° C in the frequency range of 100 MHz to 15 GHz using a time domain reflection method (TDR). Single time relaxation processes were found at 2 GHz and 15 GHz, respectively. The low frequency dispersion was inter preted in terms of the dynamics of polymeric segments based on the dielectric relaxation strength and the relaxation time. The high frequency process which is attributed to the rotational relaxation of water, indicated that water mole cules surrounding the polymeric backbone and in the pure state have a similar rotational behav…

Aqueous solutionPolymers and PlasticsRelaxation strength0206 medical engineeringRelaxation (NMR)Analytical chemistryBioengineering02 engineering and technologyDielectricLow frequency021001 nanoscience & nanotechnologyHydrazide020601 biomedical engineeringBiomaterialschemistry.chemical_compoundCrystallographyReflection (mathematics)chemistryMaterials Chemistry0210 nano-technologyDispersion (chemistry)Journal of Bioactive and Compatible Polymers
researchProduct