Search results for " Bone"
showing 10 items of 933 documents
Reduced Peak Bone Mass in Young Adults with Low Motor Competence
2023
Although suboptimal bone health has been reported in children and adolescents with low motor competence (LMC), it is not known whether such deficits are present at the time of peak bone mass. We examined the impact of LMC on bone mineral density (BMD) in 1043 participants (484 females) from the Raine Cohort Study. Participants had motor competence assessed using the McCarron Assessment of Neuromuscular Development at 10, 14, and 17 years, and a whole body dual-energy X-ray absorptiometry scan at 20 years. Bone loading from physical activity was estimated from the International Physical Activity Questionnaire at the age of 17. The association between LMC and BMD was determined using general …
Narrow-diameter implants: A systematic review and meta-analysis.
2018
OBJECTIVES Narrow-diameter implants (NDI) are claimed to be a reasonable alternative to bone augmentation procedures. The aim of this comprehensive literature review was to conduct a meta-analysis comparing the implant survival of NDI and standard diameter implants (SDI) and to provide recommendations and guidelines for application of NDI. MATERIAL AND METHODS An extensive systematic literature search was performed in the PubMed/MEDLINE and the Cochrane Library databases. NDI were classified into Category 1 (implant diameter <3.0 mm, "mini-implants"), Category 2 (implant diameter 3-3.25 mm) and Category 3 (implant diameters 3.3-3.5 mm). Clinical studies at all levels of evidence with at lea…
The influence of platform switching in dental implants. A literature review.
2010
Introduction: The platform switching concept involves the reduction of the restoration abutment diameter with respect to the diameter of the dental implant. In 1991, dental implants of 5 and 6 mm diameter platforms were introduced. However, matching-diameter prosthetic abutments were not available. These implants were restored with “standard”-diameter prosthetic components (4,1 mm). Long-term follow up around these wide-platforms showed higher levels of bone preservation. In time, it has been called platform switching. The first case report applying this concept was indexed in MedLine in 2005. Materials and Methods: The aim of this article is to carry out a literature review of articles whi…
Oral rehabilitation with tilted dental implants: A metaanalysis
2012
Objective: To compare the course of patients treated with tilted implants versus those treated conventionally with axial implants, analyzing the success rate and marginal bone loss. Material and M ethods: A PubMed search was made using the key words ?tilted implants?, ?angled implants?, ?angulated implants?, ?inclined implants? and ?maxillary atrophy.? A review was made of the articles published between 1999-2010. The inclusion criteria were the use of tilted implants, clinical series involving at least 10 patients, and a minimum follow-up of 12 months after prosthetic loading. The exclusion criteria were isolated clinical cases, studies with missing data, and publications in languages othe…
Marginal bone loss in relation to the implant neck surface: An update
2010
A review is made of the publications on the marginal bone loss of implants with a polished neck, rough neck with microthreading, and rough neck without microthreading. A PubMed search was carried out with the following key words: machined neck implant, polished neck implant, marginal bone loss, covering the period between January 1998 and March 2009. Inclusion was limited to those human clinical studies involving a minimum follow-up of 12 months, and registering the level of bone loss from the time of placement of the implant or prosthetic restoration to the end of follow-up. For most of the authors there were no significant differences in marginal bone loss between polished neck and rough …
Effects of a local single dose administration of growth hormone on the osseointegration of titanium implants.
2021
The aim of the present study was to evaluate the effect of different concentrations of growth hormone (GH) on endosteal implant?s surface at the early stages of osseointegration. Sixty tapered acid-etched titanium implants were divided into four groups: i) Collagen, used as a control group; and three experimental groups, where after collagen coating, GH was administered directly to the surface in varying concentrations: ii) 0.265 mg, iii) 0.53 mg, and iv) 1 mg. Implants were placed in an interpolated fashion in the anterior flange of C3, C4 or C5 of 15 sheep with minimum distance of 6 mm between implants. After 3-, 6- and 12-weeks of healing samples were harvested, histologically processed,…
Impact of abutment geometry on early implant marginal bone loss. A double‐blind, randomized, 6‐month clinical trial
2022
Objectives The objective of this study was to analyze the impact of the abutment width on early marginal bone loss (MBL). Material and Methods A balanced, randomized, double-blind clinical trial with two parallel experimental arms was conducted without a control group. The arms were “cylindrical” abutment and “concave” abutment. Eighty hexagonal internal connection implants, each with a diameter of 4 × 10 mm, were placed in healed mature bone. The main variable was the peri-implant tissue stability, which was measured as MBL at 8 weeks and 6 months. Results The final sample consisted of 77 implants that were placed in 25 patients. 38 (49.4%) were placed using the cylindrical abutment, and t…
Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.
2015
Objective The aim of this ex vivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Material and methods Fresh ex vivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectros…
Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series
2016
Background: The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods: A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and…
Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection
2020
The bioengineering and medical and biomedical fields are ever closer, and they manage to obtain surprising results for the development of new devices. The field of simulations and studies in silica has undergone considerable development in recent years, favoring the advancement of medicine. In this manuscript, a study was carried out to evaluate the force distribution on the implant components (In-Kone® Universal) and on the peri-implant tissues subjected to loading. With the finite element analysis and the Von Mises method, it was possible to evaluate this distribution of forces both at 0 degrees (occlusal force) and at 30 degrees; the applied force was 800 N. The obtained results on this …