Search results for " CONDITIONING"
showing 10 items of 400 documents
Activity in the rabbit somatosensory cortex reflects the active procedural memory trace of a classically conditioned eyeblink response.
2003
Behavioral responses and neural responses in the somatosensory cortex were recorded in nine rabbits during the unpaired and paired treatments of classical eyeblink conditioning with a tone conditioned stimulus (CS) and an airpuff unconditioned stimulus. During the unpaired treatment, neither the behavioral nor neural responses to the CS were observed. During the paired treatment, behavioral conditioned response (CR), accompanied by neural activity, was developed. In well-trained animals occasional failures to elicit the CR were accompanied by an absence of neural responses. Nevertheless, the CS modified the behavioral unconditioned response in paired trials, implying that the CR-failures co…
Innovative control logics for a rational utilization of electric loads and air-conditioning systems in a residential building
2015
The paper focuses on the evaluation of the impact on residential buildings of innovative control logics defined for a rational utilization of the electric loads and air-conditioning systems. The control logics are implementable thanks to a Decision Support and Energy Management Systems developed by the same authors and easily installable in new and still-existing houses. The paper shows how a significant reduction of the primary energy consumption can be obtained by controlling the air-conditioning units together with the other electric loads of the house. After having explained how the control logics operate, a simulation tool is described, developed for a preliminary evaluation of their e…
A novel renewable polygeneration system for a small Mediterranean volcanic island for the combined production of energy and water: Dynamic simulation…
2014
Abstract This paper investigates the integration of solar and geothermal energy in a novel polygeneration system producing simultaneously: electricity, thermal energy, cooling energy and fresh water. The polygeneration system under analysis includes concentrating photovoltaic/thermal solar collectors (CPVT), a Geothermal Well (GW) a multi-effect distillation (MED) system for seawater desalination, a single-stage LiBr–H2O absorption chiller and additional components, such as: storage tanks, heat exchangers and balance of plant devices. The CPVT produces simultaneously electrical energy and thermal energy, at a maximum temperature of about 100 °C. The electrical energy is delivered to the gri…
Quality Assurance and Support Measures for Solar Cooling on System Level
2016
Abstract Within the IEA SHC Task 48 “Quality assurance and support measures for Solar Cooling” the analysis and evaluation of the systems has been one of the four main focuses. Here the activities are including the lab- and field-based characterization of the systems, the definition and application of performance figures, a guideline for a reliable monitoring procedure including methods for automated error detection and an updated overview on worldwide installed DEC systems including hints and good practice examples. They are furthermore leading to three different easy-to-use tools for solar cooling systems: The LCA tool considers environmental and energetic values for the evaluation, the P…
Role of Green Coverings in Mitigating Heat Island Effects: An Analysis of Physical Models
2012
Worldwide, governments are introducing several rules and standards in the aim of limiting the quantity of primary energy for air conditioning of buildings and supporting the use of renewable source of energy for generating thermal and electric energy to be utilized in buildings such as the European Directive on the Energy Performance of Buildings [1]. Along with these interventions, another important action takes currently place in the building sector, that is the introduction of passive structural components of the envelope, able to reduce the requirements of energy for air conditioning purposes. Among these building components, the so-called green roofs are becoming more and more interest…
Building green covering for a sustainable use of energy
2013
Nowadays the growth of the cities increased built and paved areas, energy use and heat generation. The phenomenon of urban warming, called urban heat island, influences negatively outdoor comfort conditions, pollutants concentration, energy demand for air conditioning, as well as increases environmental impact due to the demand of energy generation. A sustainable technology for improving the energy efficiency of buildings is the use of green roofs and walls in order to reduce the energy consumption for conditioning in summer and improve the thermal insulation in winter. The use of green roofs and walls can contribute to mitigate the phenomenon of heat island, the emissions of greenhouse gas…
Short-term prediction of household electricity consumption: assessing weather sensitivity in a Mediterranean area
2008
Abstract Urban microclimatic variations, along with a rapid reduction of unit cost of air-conditioning (AC) equipments, can be addressed as some of the main causes of the raising residential energy demand in the more developed countries. This paper presents a forecasting model based on an Elman artificial neural network (ANN) for the short-time prediction of the household electricity consumption related to a suburban area. Due to the lack of information about the real penetration of electric appliances in the investigated area and their utilization profiles it was not possible to implement a statistical model to define the weather and climate sensitivities of appliance energy consumption. F…
Analysis of Air Cycle and Efficiency Evaluation for a Blast Freezing Tunnel Plant
2013
Air refrigerating systems offer a suitable alternative to vapour compression systems. Air can be used as working fluid in gas compression cycles for refrigeration, air conditioning and heat pump systems. This paper gives some results of theoretical investigation into improved air cycles for refrigeration systems and a comparison is made with their performances. The case-study relates to a dual purpose refrigerating plant. A blast freezing tunnel gives the coldest air stream and, in cascade, the air coming out from the tunnel is used in a channel network for feeding a lot of chilling cells. The case-study analysed indicates that there is a real possibility to build plants which will be equip…
Thermal comfort condition assessment in test buildings with different heating/cooling systems and wall envelopes
2017
Abstract The main aim of this study is a comprehensive analysis of long-term monitoring data of thermal comfort and discomfort parameters in small identical test buildings equipped with different heating/cooling systems. Calculations of PPD index expressed the human perception of thermal comfort and such discomfort factors like draught rate and vertical air temperature difference are provided for the room in winter season running three different heating systems – electric heater, air-air heat pump and air-water heat pump, as well as for the summer cooling with split type air conditioning systems. It is shown that the type of heating/cooling system and its working regime has a significant im…
Life Cycle Assessment of Solar Technologies
2015
This chapter analyses the most common solar technologies and assesses their energy and environmental performance, based on a life cycle perspective. After a preliminary description of the main technologies, the chapter presents a review of studies on solar plants, as published in scientific journals in the past decade. Successively, the chapter assesses solar plants in comparison to other renewable and non-renewable based technologies, including a discussion of uncertainties and criticalities in the assessment