Search results for " Capacity"
showing 10 items of 902 documents
A Polygenic Risk Score for Hand Grip Strength Predicts Muscle Strength and Proximal and Distal Functional Outcomes among Older Women
2022
Purpose Hand grip strength (HGS) is a widely used indicator of overall muscle strength and general health. We computed a polygenic risk score (PRS) for HGS, and examined, whether it predicted muscle strength, functional capacity and disability outcomes. Methods Genome-wide association study summary statistics for HGS from the Pan-UK Biobank was utilized. PRSs were calculated in the Finnish Twin Study on Aging (N = 429 women, 63–76 years). Strength tests included HGS, isometric knee extension, and ankle plantar flexion strength. Functional capacity was examined with the Timed Up and Go, six-minute and 10-meter walk tests, and dual-task tests. Disabilities in the basic (ADL) and instrumental …
Effects of a 10-day high-intensity interval training mesocycle on physical performance in male judo athletes
2020
Judo is an Olympic combat sport where the competition emphasizes several consecutive 20-30 seconds high-intensity efforts interspersed by short recovery periods. High-intensity block training has been found to be an efficient way to develop physical performance, wherein shorter training periods are focused on developing one or two chosen physical abilities. The purpose of this study was to investigate the effects of a 10-day high-intensity interval training period on the performance in male judo athletes. The study included pre and post-tests as well as a 10-day training intervention. The subjects were 19-28 years old men who had competed at least at the Nordic level during the last year (n…
Reliability, validity and performance determinants of the military simulation test for the assessment of anaerobic performance in soldiers
2020
Introduction: Measurements of physical fitness have been identified as one of the most important research priorities in the military. Currently, the physical fitness tests of The Finnish Defence Forces (FDF) do not include a valid and reliable anaerobic test. In order to develop job-related task simulation tests, the purpose of the study was to determine the reliability and validity of a high-intensity military simulation test (MST), which is designed to assess the task-specific anaerobic performance of soldiers. The MST includes typical combat-related maneuvers while wearing a 20 kg combat load. Methods: 22 male cadets (22.5 ± 0.8 years) volunteered to participate. The MST was performed th…
Performance of an asymmetric and asynchronous decode-and-forward FBMC relay system
2014
End-to-end link performance of an asymmetric and asynchronous dual-hop decode-and-forward (DF) relay system built up using a causal multirate filter bank multicarrier (FBMC) technique operated under Rayleigh fading is presented. Three main performance measures namely bit error rate (BER), outage probability and channel capacity are used for this evaluation and approximate closed-form expressions for them are also made available. FBMC setup is modeled in exact form without any approximations while customizing to one of the most efficient subcarrier filter. Simulations are carried out in quasi-static multipath fading channels under symmetric, asymmetric, synchronous and asynchronous condition…
Design of a Cleaning Program for a PV Plant Based on Analysis of Energy Losses
2015
Solar photovoltaic (PV) energy has grown significantly over the past few years. However, despite the increase in installed capacity, this energy source still raises important concerns related to the variability of power production. The short-term effects such as cloud shadowing and supply interruptions, as well as long-term effects such as dust accumulation, seasonal variation, and ageing of PV modules, can cause variability of power production. Therefore, the analysis of all the variability sources in order to provide statistically consistent power production data is an important challenge. This study presents a methodology to analyze data from a PV plant in order to have an independent ev…
Does innovativeness reduce startup survival rates?
2015
There are two competing hypotheses explaining how innovativeness influences the survival of startups: On the one hand, innovativeness is argued to foster survival-enhancing attributes (e.g., market power and cost efficiency) and capabilities (e.g., absorptive capacity). On the other hand, an innovative startup faces (and bears the associated risks of) liabilities of newness and smallness that exceed those of its non-innovative counterparts. The available empirical literature addressing this theoretical tension mostly supports the former hypothesis; we suggest that this finding is, in part, driven by the common practice of employing an ex post measure that already embodies a degree of succes…
Tree and orchard variability of Silver King nectarine(Prunus persica (L.) Batsch) fruit quality components
2013
The variability of crop quality accounts for most of seasonal variation of farmers’ incomes, since fruit growth and quality components may greatly change according to various environmental and within-tree factors. Canopy architecture and orchard layout are mainly responsible for fruit size, quality and its variability. A positive relationship was measured in peach between intercepted radiation and PAR and Trolox equivalent antioxidant capacity (TEAC). This study was carried out to measure within tree and orchard variability of fruit of the early ripening cv. Silver King nectarine (Prunus persica (L.), Batsch) 8-years-old peach trees trained to a Y-shape and Delayed vase. Fruit were picked t…
Comparison of inter-trial recovery times for the determination of critical power and W' in cycling
2017
Critical Power (CP) and W’ are often determined using multi-day testing protocols. To investigate this cumbersome testing method, the purpose of this study was to compare the differences between the conventional use of a 24-h inter-trial recovery time with those of 3 h and 30 min for the determination of CP and W’. Methods: 9 moderately trained cyclists performed an incremental test to exhaustion to establish the power output associated with the maximum oxygen uptake (p V O2max), and 3 protocols requiring time-to-exhaustion trials at a constant work-rate performed at 80%, 100% and 105% of p VO2max. Design: Protocol A utilised 24-h inter-trial recovery (CP24/W’24), protocol B utilised 3-h in…
In-Depth Characterization of Bioactive Extracts from Posidonia oceanica Waste Biomass
2019
© 2019 by the authors.