Search results for " Collider"
showing 10 items of 1415 documents
CP violation and limits on New Physics including recent B-s measurements
2007
We analyse present constraints on the SM parameter space and derive, in a model independent way, various bounds on New Physics contributions to $B_d^0$--$\bar B_d^0$ and $B_s^0$--$\bar B_s^0$ mixings. Our analyses include information on a large set of asymmetries, leading to the measurement of the CKM phases $\gamma$ and $\bar\beta$, as well as recent data from D0 and CDF related to the $B_s^0$--$\bar B_s^0$ system such as the measurement of $\Delta M_{B_s}$, $A_{SL}$ and $\Delta\Gamma_{s}^{CP}$. We examine in detail several observables such as the asymmetries $A_{sl}^d$, $A_{SL}$, the width differences $\Delta\Gamma_{d}$ and $\Delta\Gamma_{s}^{CP}$ and discuss the r\^ole they play in estab…
Pion–kaon femtoscopy and the lifetime of the hadronic phase in Pb−Pb collisions at sNN=2.76 TeV
2021
Abstract In this paper, the first femtoscopic analysis of pion–kaon correlations at the LHC is reported. The analysis was performed on the Pb–Pb collision data at s NN = 2.76 TeV recorded with the ALICE detector. The non-identical particle correlations probe the spatio-temporal separation between sources of different particle species as well as the average source size of the emitting system. The sizes of the pion and kaon sources increase with centrality, and pions are emitted closer to the centre of the system and/or later than kaons. This is naturally expected in a system with strong radial flow and is qualitatively reproduced by hydrodynamic models. ALICE data on pion–kaon emission asymm…
Mass Measurement on the rp-Process Waiting Point 72Kr
2004
The mass of one of the three major waiting points in the astrophysical rp process $^{72}$Kr was measured for the first time with the Penning trap mass spectrometer ISOLTRAP. The measurement yielded a relative mass uncertainty of $\deltam/m = 1.2\times 10–7 (\deltam$ = 8 keV). $^{73,74}$Kr, also needed for astrophysical calculations, were measured with more than 1 order of magnitude improved accuracy. We use the ISOLTRAP masses of $^{72–74}$Kr to reanalyze the role of $^{72}$Kr (T$_{1/2}$ = 17.2 s) in the rp process during x-ray bursts and conclude that $^{72}$Kr is a strong waiting point delaying the burst duration with at least 80\% of its $\beta$-decay half-life.
The ASTERIX spectrometer at LEAR
1989
The ASTERIX spectrometer has been used to study the formation and the ground state of the pp atom and exclusive final states of pp annihilation at rest in a H2 gas target at NTP, using antiprotons from the Low Energy Antiproton Ring (LEAR) at CERN. The article describes the mechanical construction of the apparatus, the trigger logic, the chamber readout, and the data acquisition system. The detector calibration and the offline processing of the 55 million reconstructed events are illustrated. An overview is given about the new physics results obtained by the experiment.
Liquid argon calorimeter performance at high rates
2012
Abstract We project the performance of the ATLAS liquid argon endcap and forward calorimeters at the planned high luminosity LHC option HL-LHC by exposing small calorimeter modules of the electromagnetic, hadronic, and forward calorimeters to high intensity beams at IHEP/Protvino. The beam intensity extends well beyond the maximum expected for these calorimeters at HL-LHC. The signal reconstruction and calorimeter performance have been studied in full detail.
Light exotic isotopes: recent beam developments and physics applications at ISOLDE
2002
This paper is divided in three parts: (i) the measurement of yields and decay losses of Li and Be isotopes released from a thin foil tantalum target at the CERN/ISOLDE PS-Booster; (ii) results from beta-decay experiments on Be-12 and Be-14, an improved half-life of 21.49(3) ms has been obtained for Be-12; (iii) the beta-decay of C-9. An outline of the analysis procedure to determine the branching at high excitation energies is given. The ground-state branch has been determined to 54.1(15)%.
Pre-production validation of the ATLAS level-1 calorimeter trigger system
2006
The Level-1 Calorimeter Trigger is a major part of the first stage of event selection for the ATLAS experiment at the LHC. It is a digital, pipelined system with several stages of processing, largely based on FPGAs, which perform programmable algorithms in parallel with a fixed latency to process about 300 Gbyte/s of input data. The real-time output consists of counts of different types of trigger objects and energy sums. Prototypes of all module types have been undergoing intensive testing before final production during 2005. Verification of their correct operation has been performed stand-alone and in the ATLAS test-beam at CERN. Results from these investigations will be presented, along …
Deceleration of antiprotons from MeV to keV energies
1993
Trapping of antiprotons for high precision measurements at the Low Energy Antiproton Ring (LEAR/CERN) requires the deceleration of the antiproton beam from typically 5.8 MeV energy down to 10 keV for final capture in standard Penning traps. Two methods, the degradation of the beam in thin foils and the deceleration of the beam in an inverse cyclotron are investigated so far. The foil technique was successfully demonstrated with trapping efficiencies up to a few 10−4 and is now routinely used in the high precision measurement of the antiprotonproton mass ratio. The degradation foil method is compared with the deceleration technique using an inverse cyclotron tested also at LEAR.
Upgrade Analog Readout and Digitizing System for ATLAS TileCal Demonstrator
2013
A potential upgrade for the front-end electronics and signal digitization and data acquisition system of the ATLAS hadron calorimeter for the high luminosity Large Hadron Collider (HL-LHC) is described. A Demonstrator is being built to readout a slice of the TileCal detector. The on-detector electronics includes up to 48 Analog Front-end Boards for PMT analog signal processing, 4 Main Boards for data digitization and slow controls, 4 Daughter Boards with high speed optical links to interface the on-detector and off-detector electronics. Two super readout driver boards are used for off-detector data acquisition and fulfilling digital trigger.\n The ATLAS Tile Calorimeter on-detector electron…
Measurement of the polarization of $$\Lambda ^0 , \overline \Lambda ^0 , \Sigma ^ + $$ and ?? produced in a ?? beam of 330 GeV/c
1995
The polarization of Lambda0 , AntiLambda0 , Sigma+ and Xi- inclusively produced in Sigma- induced interactions at 330 GeV has been measured in the experiment WA89 at CERN. This is the first measurement of polarization of baryons produced by a hyperon beam. No polarization of AntiLambda is observed, as was also the case in proton beam data. At transverse momenta of about 1~GeV/c Lambda0 and Sigma+ show little polarization, significantly lower than in the proton beam data, while Xi- have a polarization comparable to the polarization of Lambda0 produced in proton beams. The polarization of Lambda0, AntiLambda0, Sigma+ and Xi- inclusively produced in Sigma- induced interactions at 330 GeV has b…