Search results for " Computer-Assisted"
showing 10 items of 1033 documents
Automatic fuzzy classification of the washout curves from magnetic resonance first-pass perfusion imaging after myocardial infarction.
2005
International audience; Abstract: Objectives: We sought to investigate the diagnostic ability of cardiac magnetic resonance imaging (MRI) perfusion in acute reper-fused myocardial infarction. The study used fuzzy logic to automatically classify signal intensity-time curves from myocardial segments into 3 categories: normal, hypointense, and Hyperintense. Materials and Methods: Thirty-eight patients with myocardial infarction underwent short-axis cine-MRI and contrast-enhanced MRI to provide data on wall thickening and the transmural extent of infarction. Of these, 17 had a second cardiac MRI to ascertain the functional recovery in each segment. Results: The fuzzy logic based classification …
Factorial invariance of a computerized version of the GAD-7 across various demographic groups and over time in primary care patients.
2019
Abstract Background The Generalized Anxiety Disorder 7-item scale (GAD-7) is commonly used by clinicians and researchers to screen for anxiety disorders and to monitor anxiety symptoms in primary care. However, findings regarding its factor structure are mixed, with most studies reporting a best-fitting for a one-factor structure, whereas others indicate a two-factor model. To be valid for comparisons, the GAD-7 should measure the same latent construct with the same structure across groups and over time. We aimed to examine the best-fit factor structure model of the GAD-7 among primary care patients and to evaluate its measurement invariance. Methods A total of 1255 patients completed the c…
Accuracy of SWI sequences compared to T2*-weighted gradient echo sequences in the detection of cerebral cavernous malformations in the familial form
2016
Purpose The purpose of this study was to assess the accuracy of susceptibility-weighted imaging (SWI), compared with T2*-weighted gradient echo (GRE) imaging in assessing cerebral cavernous malformations. Materials and methods We retrospectively evaluated 21 patients with a familial form of cavernous malformation. Magnetic resonance (MR) protocol included non-enhanced and contrast-enhanced fast-spin echo (FSE) T1-weighted sequences, FSE T2-weighted sequences, fluid-attenuated inversion-recovery (FLAIR), GRE T2*-weighted and SWI sequences. Images were reviewed in consensus by two expert neuroradiologists to assess the location, number, size and conspicuity of the lesions on T2*-weighted GRE …
Three-dimensional distribution of trabecular bone density and cortical thickness in the distal humerus
2008
One major barrier to osteosynthesis in distal humeral fractures is poor bone quality. This study was an attempt to measure the bone quality in the distal humerus.We measured the distribution of total bone mineral density (BMD), trabecular BMD (tBMD), and cortical thickness (CTh) in the distal humerus using peripheral quantitive computed tomography. Four slices in the infracondylar, supracondylar, and distal disphyseal regions of 25 human cadaver humeri were investigated.Total BMD decreased continuously from the distal diaphysis to the trochlea. Within the infracondylar region, the capitellum was the region of lowest tBMD and CTh (P.001). Measurements in anterior regions were higher than in …
Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal f…
2007
Purpose To investigate the parallel acquisition technique sensitivity encoding incorporating temporal filtering (TSENSE) with three saturation-recovery (SR) prepared pulse sequences (SR turbo fast low-angle shot [SR-TurboFLASH], SR true fast imaging with steady precession [SR-TrueFISP], and SR-prepared segmented echo-planar-imaging [SR-segEPI]) for semiquantitative first-pass myocardial perfusion imaging. Materials and Methods In blood- and tissue-equivalent phantoms the relationship between signal intensity (SI) and contrast-medium concentration was evaluated for the three pulse sequences. In volunteers, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normalized upslopes (N…
Mental Imagery Training Increases Wanting of Rewards and Reward Sensitivity and Reduces Depressive Symptoms.
2017
High reward sensitivity and wanting of rewarding stimuli help to identify and motivate repetition of pleasant activities. This behavioral activation is thought to increase positive emotions. Therefore, both mechanisms are highly relevant for resilience against depressive symptoms. Yet, these mechanisms have not been targeted by psychotherapeutic interventions. In the present study, we tested a mental imagery training comprising eight 10-minute sessions every second day and delivered via the Internet to healthy volunteers (N = 30, 21 female, mean age of 23.8 years, Caucasian) who were preselected for low reward sensitivity. Participants were paired according to age, sex, reward sensitivity, …
An Information-Theoretic Framework to Map the Spatiotemporal Dynamics of the Scalp Electroencephalogram
2016
We present the first application of the emerging framework of information dynamics to the characterization of the electroencephalography (EEG) activity. The framework provides entropy-based measures of information storage (self entropy, SE) and information transfer (joint transfer entropy (TE) and partial TE), which are applied here to detect complex dynamics of individual EEG sensors and causal interactions between different sensors. The measures are implemented according to a model-free and fully multivariate formulation of the framework, allowing the detection of nonlinear dynamics and direct links. Moreover, to deal with the issue of volume conduction, a compensation for instantaneous e…
Instantaneous Transfer Entropy for the Study of Cardiovascular and Cardio-Respiratory Nonstationary Dynamics
2017
Objective: Measures of transfer entropy (TE) quantify the direction and strength of coupling between two complex systems. Standard approaches assume stationarity of the observations, and therefore are unable to track time-varying changes in nonlinear information transfer with high temporal resolution. In this study, we aim to define and validate novel instantaneous measures of TE to provide an improved assessment of complex nonstationary cardiorespiratory interactions. Methods: We here propose a novel instantaneous point-process TE (ipTE) and validate its assessment as applied to cardiovascular and cardiorespiratory dynamics. In particular, heartbeat and respiratory dynamics are characteriz…
Single region of interest versus multislice T2* MRI approach for the quantification of hepatic iron overload.
2011
Purpose To evaluate the effectiveness of the single ROI approach for the detection of hepatic iron burden in thalassemia major (TM) patients in respect to a whole liver measurement. Materials and Methods Five transverse hepatic slices were acquired by a T2* gradient-echo sequence in 101 TM patients and 20 healthy subjects. The T2* value was calculated in a single region of interest (ROI) defined in the medium-hepatic slice. Moreover, the T2* value was extracted on each of the eight ROIs defined in the functionally independent segments. The mean hepatic T2* value was calculated. Results For patients, the mean T2* values over segments VII and VIII were significantly lower. This pattern was su…
Improved T2* assessment in liver iron overload by magnetic resonance imaging.
2009
In the clinical MRI practice, it is common to assess liver iron overload by T2* multi-echo gradient-echo images. However, there is no full consensus about the best image analysis approach for the T2* measurements. The currently used methods involve manual drawing of a region of interest (ROI) within MR images of the liver. Evaluation of a representative liver T2* value is done by fitting an appropriate model to the signal decay within the ROIs vs. the echo time. The resulting T2* value may depend on both ROI placement and choice of the signal decay model. The aim of this study was to understand how the choice of the analysis methodology may affect the accuracy of T2* measurements. A softwar…