Search results for " Computer-Assisted"

showing 10 items of 1033 documents

Identification of unknown dead bodies by X-ray image comparison of the skull using the X-ray simulation program FoXSIS.

2001

The aim of the study was to improve the objectivity of X-ray image comparison for the identification of unknown dead individuals. CT-data were collected for 30 macerated skulls. An already presented computer program which uses CT data to establish virtual X-ray images was used to obtain X-rays with different beam angulations simulating rotation, dorsal flexion, and ventral flexion. Specific parameters were measured on the simulated images. The frontal sinus reveals the highest variability not only between the individual skulls but also within an individual skull in different positions. The most consistent parameters with respect to different positions were the skull breadth, the biorbital b…

AdultMalemedicine.medical_specialtyImage processingPathology and Forensic MedicineBlind studymedicineImage Processing Computer-AssistedHumansComputer SimulationMathematicsbusiness.industrySkullPattern recognitionSurgeryIdentification (information)Skullmedicine.anatomical_structureX ray imageForensic radiologyForensic AnthropologyFrontal SinusFemaleArtificial intelligenceTomographybusinessTomography X-Ray ComputedLawRotation (mathematics)SoftwareForensic science international
researchProduct

Role of high-resolution ultrasonography without and with real-time spatial compound imaging in evaluating the injured posterior cruciate ligament: pr…

2009

This study sought to compare high-resolution ultrasonography (HRUS) without and with compound imaging in evaluating the injured posterior cruciate ligament (PCL). Thirteen patients with a magnetic resonance imaging (MRI) diagnosis of PCL lesions (ten acute and three chronic) and 20 healthy controls underwent conventional and compound HRUS performed by the same radiologist who was blinded to the subjects' case-control status. The PCL was scanned in a longitudinal direction in all cases. HRUS images were assessed for PCL thickness by two other radiologists blinded to the number and type of PCL injury. PCLs were classified as normal or injured, and the latter as having acute or chronic injurie…

AdultMalemedicine.medical_specialtyKnee InjuriesSeverity of Illness IndexmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingCompound imagingNeuroradiologyUltrasonographymedicine.diagnostic_testbusiness.industryUltrasoundReproducibility of ResultsPosterior cruciate ligament · Knee · Sonography · Real-time spatial compound sonography · Magnetic resonance imagingMagnetic resonance imagingInterventional radiologyGeneral Medicinemusculoskeletal systemMagnetic Resonance Imagingmedicine.anatomical_structurePosterior cruciate ligamentCase-Control StudiesHigh resolution ultrasonographyFemalePosterior Cruciate LigamentRadiologyUltrasonographybusinessLa Radiologia medica
researchProduct

Diagnostic performance of reformatted isotropic thin-section helical CT images in the detection of superior semicircular canal dehiscence

2017

Purpose The purpose of this article is to assess the diagnostic performance of computed tomography (CT) reformatted images for detection of superior semicircular canal (SSC) dehiscence. Material and methods Forty-two patients, with sound- and/or pressure-induced vestibular symptoms, and 42 control participants underwent helical CT examination with a highly collimated beam (0.5 mm). Reformatted images of the vestibular labyrinth were obtained in the standard axial and coronal planes (group A images), and in a plane parallel and perpendicular to the SSC (group B images). Diagnostic performance obtained by evaluating the group A images alone and the group B images alone was analyzed by using t…

AdultMalemedicine.medical_specialtyLabyrinth DiseasesTullio phenomenonDehiscenceCollimated light03 medical and health sciences0302 clinical medicinecomputed tomography; CT; dehiscence of the superior semicircular canal; superior semicircular canal; temporal bone; Tullio phenomenon; Radiology Nuclear Medicine and Imaging; Neurology (clinical)medicineHumansRadiology Nuclear Medicine and imaging030223 otorhinolaryngologyAgedAged 80 and overReceiver operating characteristicSemicircular canalbusiness.industryIsotropycomputed tomographyGeneral MedicineMiddle AgedSemicircular CanalsHelical ctmedicine.anatomical_structureCoronal planeRadiographic Image Interpretation Computer-AssistedFemalesuperior semicircular canaltemporal boneNeurology (clinical)RadiologyHead and Neck ImagingTullio phenomenonmedicine.symptombusinessTomography Spiral Computeddehiscence of the superior semicircular canal030217 neurology & neurosurgeryCTThe Neuroradiology Journal
researchProduct

Intrahepatic biliary anatomy derived from right graft adult live donor liver transplantation

2008

Abstract Objective The successful management of the bile duct in right graft adult live donor liver transplantation requires knowledge of both its central (hilar) and distal (sectorial) anatomy. The purpose of this study was to provide a systematic classification of its branching patterns to enhance clinical decision-making. Patients and Methods We analyzed three-dimensional computed tomography (3-D CT) imaging reconstructions of 139 potential live liver donors evaluated at our institution between January 2003 and June 2007. Results Fifty-four (n = 54 or 38.8%) donor candidates had a normal (classic) hilar and sectorial right bile duct anatomy (type I). Seventy-eight (n = 78 or 56.1%) cases…

AdultMalemedicine.medical_specialtyLive donormedicine.medical_treatmentCholecystographyHepatic Duct CommonLiver transplantationliverImage Processing Computer-AssistedLiving DonorsmedicineHumansRetrospective StudiesTransplantationmedicine.diagnostic_testBile ductbusiness.industryGallbladderGallbladderRetrospective cohort studyMiddle AgedCholecystographyLiver TransplantationSurgeryBiliary anatomymedicine.anatomical_structureBiliary tractFemaleSurgeryTomography X-Ray Computedbusiness
researchProduct

Normal reference values of multilayer longitudinal strain according to age decades in a healthy population: A single-centre experience.

2017

Aims Recent advancements in echocardiographic technology allow to analyse myocardial strain in multiple layers. Little is known about the impact of age on layer-specific longitudinal strain in healthy subjects. The aim of this study was to analyse the influence of age on multilayer longitudinal strain and establish normal reference values of layer-specific strain according to age decades in a healthy population referring to our echo laboratory using 2D speckle-tracking echocardiography with layer-specific software. Methods and results Two-hundred sixty-six healthy, consecutive subjects (mean age = 39.2 ± 17.5 years, women/men = 137/129), free of cardiovascular risk factors, were enrolled. S…

AdultMalemedicine.medical_specialtyLongitudinal strain030204 cardiovascular system & hematologyVentricular Function LeftCohort Studies03 medical and health sciences0302 clinical medicineReference ValuesInternal medicineLinear regressionImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineProspective StudiesProspective cohort studyObserver VariationStrain (chemistry)business.industrysubendocardial strainConfoundingsubepicardial strainAge FactorsStroke VolumeGeneral MedicineMiddle AgedHealthy VolunteersageingAgeingEchocardiographyReference valuesCardiologyLinear ModelsFemaleCardiology and Cardiovascular Medicinebusinessglobal longitudinal strainglobal longitudinal strain subepicardial strain subendocardial strain echocardiography ageingCohort studyEuropean heart journal. Cardiovascular Imaging
researchProduct

Effect of Kernels Used for the Reconstruction of MDCT Datasets on the Semi-Automated Segmentation and Volumetry of Liver Lesions

2014

Purpose: To evaluate the effect of different reconstruction kernels on the semi-automated segmentation of liver lesions in MDCT. Materials and Methods: A total 62 liver lesions were measured by three independent radiologists with the semi-automated segmentation software Oncology-Prototype (Fraunhofer MEVIS, Siemens Healthcare, Germany) using MDCT datasets (3-mm slice thickness, 2-mm increment) reconstructed with standard, soft and detailed kernels (Philips B, A and D). To ensure objective measurements, only lesions with satisfactory initial segmentation were included, and manual correction was not used. The effective diameter and volume were recorded for each lesion. Segmentation in the sof…

AdultMalemedicine.medical_specialtyLung NeoplasmsInitial SeedAutomated segmentationBreast NeoplasmsTumor responseSensitivity and SpecificityMultidetector Computed TomographyImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingSegmentationTumor growthAgedMathematicsAged 80 and overbusiness.industryLiver NeoplasmsPattern recognitionSpiral Cone-Beam Computed TomographyGold standard (test)Middle AgedTumor BurdenEffective diameterLiverKernel (statistics)FemaleArtificial intelligenceRadiologyColorectal NeoplasmsbusinessSoftwareRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Cerebrovascular and cardiovascular variability interactions investigated through conditional joint transfer entropy in subjects prone to postural syn…

2017

Objective: A model-based conditional transfer entropy approach was exploited to quantify the information transfer in cerebrovascular (CBV) and cardiovascular (CV) systems in subjects prone to develop postural syncope. Approach: Spontaneous beat-to-beat variations of mean cerebral blood flow velocity (MCBFV) derived from a transcranial Doppler device, heart period (HP) derived from surface electrocardiogram, mean arterial pressure (MAP) and systolic arterial pressure (SAP) derived from finger plethysmographic arterial pressure device were monitored at rest in supine position (REST) and during 60° head-up tilt (TILT) in 13 individuals (age mean ± standard deviation: 28 ± 9 years, min-max r…

AdultMalemedicine.medical_specialtyMean arterial pressureSupine positioncerebral autoregulationAdolescentPhysiologyUltrasonography Doppler TranscranialEntropyBiomedical EngineeringBiophysics030204 cardiovascular system & hematologyBaroreflexCerebral autoregulationSyncope03 medical and health sciencesElectrocardiographyYoung Adult0302 clinical medicinehead-up tiltHeart RatePhysiology (medical)Internal medicineinformation transfermedicineHeart rate variabilityHumansbaroreflexArterial Pressurebusiness.industryautonomic nervous systemheart rate variabilitySignal Processing Computer-AssistedTranscranial DopplerPlethysmographyBlood pressureBiophysicCerebral blood flowpostural syncopeAnesthesiaCerebrovascular CirculationSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaCardiologyFemaleDisease Susceptibilitybusiness030217 neurology & neurosurgeryHumanPhysiological measurement
researchProduct

Correlation between fatigue and brain atrophy and lesion load in multiple sclerosis patients independent of disability.

2007

Abstract Background Fatigue is a major problem in multiple sclerosis (MS), and its association with MRI features is debated. Objective To study the correlation between fatigue and lesion load, white matter (WM), and grey matter (GM), in MS patients independent of disability. Methods We studied 222 relapsing remitting MS patients with low disability (scores ≤ 2 at the Kurtzke Expanded Disability Status Scale). Lesion load, WM and GM were measured by fully automated, operator-independent, multi-parametric segmentation method. T1 and T2 lesion volume were also measured by a semi-automated method. Fatigue was assessed by the Fatigue Severity Scale (FSS), and patients divided in high-fatigue (FS…

AdultMalemedicine.medical_specialtyMultiple SclerosisStatistics as TopicGrey matterLesionWhite matterCentral nervous system diseaseDisability EvaluationAtrophyInternal medicinemedicineImage Processing Computer-AssistedHumansRisk factorFatigueAnalysis of VarianceBrain Mappingbusiness.industryMultiple sclerosisBrainmedicine.diseaseMagnetic Resonance ImagingSurgeryOxygenMultiple Sclerosis fatiguemedicine.anatomical_structureNeurologymultiple sclerosiFemaleNeurology (clinical)Analysis of variancemedicine.symptomAtrophybusinessbrain atrophyMRI
researchProduct

Semi-automated retinal vessel analysis in nonmydriatic fundus photography.

2013

Purpose Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methods matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial–venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the r…

AdultMalemedicine.medical_specialtyMydriaticsComputer scienceRetinal ArteryCardiovascular risk factorsBlood PressureFundus (eye)Diagnostic Techniques Ophthalmologicalchemistry.chemical_compoundYoung AdultSoftwareHypertensive retinopathyOphthalmologymedicineImage Processing Computer-AssistedPhotographyHumansIntraocular PressureReproducibilitymedicine.diagnostic_testbusiness.industryFundus photographyReproducibility of ResultsRetinalGeneral MedicineMiddle Agedmedicine.diseaseRetinal VeinRetinal vesselOphthalmologychemistryOptometryFemalebusinessAlgorithmsSoftwareActa ophthalmologica
researchProduct

Disturbed structural connectivity is related to inattention and impulsivity in adult attention deficit hyperactivity disorder

2010

Inattention and impulsivity are the most prominent clinical features of attention deficit hyperactivity disorder (ADHD) in adulthood. Structural and functional neuroimaging studies of subjects with ADHD have demonstrated abnormalities in several brain areas, including fronto-striatal and fronto-cerebellar networks. Mostly, these studies were based on volumetric measurements and have been conducted in children. We investigated white matter (WM) integrity and correlation with measures of attention and impulsivity in adult patients with ADHD adopting diffusion tensor imaging (DTI). N = 37 (21 males) never-medicated adult patients with ADHD combined subtype and N = 34 (16 males) healthy control…

AdultMalemedicine.medical_specialtyNeuropsychological TestsAudiologyImpulsivitybehavioral disciplines and activitiesWhite matterFunctional neuroimagingRating scaleImage Interpretation Computer-AssistedNeural Pathwaysmental disordersFractional anisotropymedicineHumansAttention deficit hyperactivity disorderPsychiatrymedicine.diagnostic_testGeneral NeuroscienceBrainNeuropsychological testmedicine.diseaseDiffusion Magnetic Resonance Imagingmedicine.anatomical_structurenervous systemAttention Deficit Disorder with HyperactivityImpulsive BehaviorFemalemedicine.symptomPsychologyDiffusion MRIEuropean Journal of Neuroscience
researchProduct