A software tool to acquire, synchronise and playback multimedia data: an application in kinesiology
2000
Assessing the physical condition of the human body frequently requires evaluating different tests performed by different devices. This information has to be analysed simultaneously to derive conclusions, and so a temporal relationship must be established between the data sources. In this paper, synchronisation of the sources of information is achieved by synchronising the clocks of computers connected in a Local Area Network. A clock synchronisation protocol is used and a global time is stamped in each information data flow. During analysis, the time-stamp is used to playback the data in a synchronised way. The proposed system is valid for any medical application in which data synchronisati…
Dopamine agonist cabergoline reduces hemoconcentration and ascites in hyperstimulated women undergoing assisted reproduction.
2007
Abstract Context: Ovarian hyperstimulation syndrome (OHSS) results from increased vascular permeability (VP) caused by ovarian hypersecretion of vascular endothelial growth factor (VEGF), which activates its receptor-2. In animals, the dopamine receptor 2 agonist cabergoline (Cb2) inactivates VEGF receptor-2 and prevents increased VP. Objective: Our objective was to test whether Cb2 reduces VP and prevents OHSS in humans. Design: We conducted a prospective, randomized, double-blind study on oocyte donors at risk of developing OHSS (>20 follicles, >12 mm developed, and >20 oocytes retrieved). Interventions: Cb2 0.5 mg/d (n = 37) or a placebo (n = 32) was administered fro…
Endoscopic surgery of the rhinobasis with a computer-assisted localizer
1996
The endoscope is useful for the diagnosis and surgical therapy of diseases of the nose, the paranasal sinuses and its neighboring regions, and allows for microinvasive, functional approaches. The reduced invasiveness of therapeutic procedures is sometimes accompanied by insufficient clearness of the surgical field, however. This significant problem is solved by the computer-assisted-surgery (CAS) system, an intraoperative localizer. It allows continuous orientation based on three-dimensional reconstructed preoperative CT scans with superimposed positioning of the endoscope. We have now adapted CAS for endoscopic sinus surgery, which meant that a variety of visualization methods were tested.…
Choledochocele imaged with magnetic resonance cholangiography.
2000
Choledochal cysts are rare developmental malformations of the biliary tree. Percutaneous and endoscopic ultrasound, as well as endoscopic retrograde cholangiopancreatography, are recommended diagnostic tools. Magnetic resonance cholangiography may also contribute to the workup and treatment plan of patients with choledochal cysts. We report a 25-yr-old white woman with episodic nausea and moderate epigastric dyscomfort. Magnetic resonance cholangiography showed a rather spherical, cyst-like, fluid-filled structure in continuity with the prepapillary segment of the common bile duct, thus making a choledochocele (type III choledochal cyst) likely. The patient was treated by endoscopic sphinct…
Direct image-guided retroperitoneal approach and treatment of the pancreas by using natural orifice transluminal endoscopic surgery after EUS sugar-a…
2021
Advances in endoscopic imaging of colorectal neoplasia.
2010
Colon cancer screening is arguably the most important activity performed by gastroenterologists. Recent decreases in rates of death from colorectal cancer indicate that screening methods such as colonoscopy have a positive impact. There is still room for improvement, however, particularly in prevention of right-sided colon cancer. Practice issues, such as making colonoscopy more comfortable, safer, and less costly, are keys to continued success in cancer prevention. Colonoscopy techniques, technologies, and quality control measures have advanced to improve detection, classification, and removal of early neoplasias. In particular, slow, careful inspection of the colon by gastroenterologists …
Dental anatomy portrayed with microscopic volume investigations
1993
The clinical treatment of the root canal of teeth--called endodontics--assumes a precise idea of the spatial arrangement of the anatomy of teeth and their inner structure. By using computer-assisted data acquisition from filmed sequences of histologic serial sections and a special kind of magnetic resonance microscope--the Stray Field Imaging (STRAFI)--volume investigations were carried out using special functions of a newly developed 3D software. Possible applications and future perspectives are discussed.
Empirical mode decomposition and neural network for the classification of electroretinographic data
2013
The processing of biosignals is increasingly being utilized in ambulatory situations in order to extract significant signals' features that can help in clinical diagnosis. However, this task is hampered by the fact that biomedical signals exhibit a complex behaviour characterized by strong non-linear and non-stationary properties that cannot always be perceived by simple visual examination. New processing methods need be considered. In this context, we propose to apply a signal processing method, based on empirical mode decomposition and artificial neural networks, to analyse electroretinograms, i.e. the retinal response to a light flash, with the aim to detect and classify retinal diseases…
A microcontroller-based portable electrocardiograph recorder.
2004
We describe a low cost portable Holler design that can be implemented with off-the-shelf components. The recorder is battery powered and includes a graphical display and keyboard. The recorder is capable of acquiring up to 48 hours of continuous electrocardiogram data at a sample rate of up to 250 Hz.
Power Consumption Analysis of Operating Systems for Wireless Sensor Networks
2010
In this paper four wireless sensor network operating systems are compared in terms of power consumption. The analysis takes into account the most common operating systems-TinyOS v1.0, TinyOS v2.0, Mantis and Contiki-running on Tmote Sky and MICAz devices. With the objective of ensuring a fair evaluation, a benchmark composed of four applications has been developed, covering the most typical tasks that a Wireless Sensor Network performs. The results show the instant and average current consumption of the devices during the execution of these applications. The experimental measurements provide a good insight into the power mode in which the device components are running at every moment, and t…