Search results for " Computer"
showing 10 items of 6910 documents
An Internet-Based Self-Help Treatment for Fear of Public Speaking: A Controlled Trial
2010
Abstract This study offers data about the efficacy of “Talk to Me,” an Internet-based telepsychology program for the treatment of fear of public speaking that includes the most active components in cognitive-behavior therapy (CBT) for social phobia (exposure and cognitive therapies). One hundred twenty-seven participants with social phobia were randomly assigned to three experimental conditions: (a) an Internet-based self-administered program; (b) the same program applied by a therapist; (c) a waiting-list control group. Results showed that both treatment conditions were equally efficacious. In addition, Talk to Me and the same treatment applied by a therapist were more efficacious than the…
Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size
1999
Objectives: To determine whether individualized selection of double-lumen tubes or alternatives based on three-dimensional reconstruction of the tracheobronchial image from routine preoperative computed tomography (CT) scans leads to clinically appropriate choices. Design: Prospective observational study; comparison to historic controls. Setting: Anesthesia and radiology facilities of a university medical center. Participants: Forty-nine patients undergoing thoracic surgery requiring one-lung ventilation. Interventions: Three-dimensional image reconstruction of individual tracheobronchial anatomy was performed from routine preoperative spiral CT scans as well as from scans of five left-side…
Digital image analysis of liver collagen predicts clinical outcome of recurrent hepatitis C virus 1 year after liver transplantation.
2011
Clinical outcomes of recurrent hepatitis C virus after liver transplantation are difficult to predict. We evaluated collagen proportionate area (CPA), a quantitative histological index, at 1 year with respect to the first episode of clinical decompensation. Patients with biopsies at 1 year after liver transplantation were evaluated by Ishak stage/grade, and biopsy samples stained with Sirius red for digital image analysis were evaluated for CPA. Cox regression was used to evaluate variables associated with first appearance of clinical decompensation. Receiver operating characteristic (ROC) curves were also used. A total of 135 patients with median follow-up of 76 months were evaluated. At 1…
Investigating centre of mass stabilisation as the goal of posture and movement coordination during human whole body reaching
2000
In the light of experimental results showing significant forward centre of mass (CoM) displacements within the base of support, this study investigated if whole body reaching movements can be executed whilst keeping the CoM fixed in the horizontal axis. Using kinematic simulation techniques, angular configurations were recreated from experimental data imposing two constraints: a constant horizontal position of the CoM and an identical trajectory of the hand to grasp an object. The comparison between recorded and simulated trials showed that stabilisation of the CoM was associated with greater backward hip displacements, which became more marked with increasing object distance. This was in c…
Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences
2005
Purpose To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. Materials and Methods End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats pe…
Online detection of rem sleep based on the comprehensive evaluation of short adjacent eeg segments by artificial neural networks
1997
Abstract 1. 1. For scientific and clinical requirements the present objective is a robust automatic online algorithm to detect rapid eye movement (REM) steep from single channel sleep EEG data without using EMG or EOG information. 2. 2. For data preprocessing 20 seconds time periods of the continuous EEG activity are digitally filtered in 7 frequency bands. Then the RMS values of these filtered signals are calculated along segments of 2.5 seconds. The resulting matrix of RMS values is representing information on the power of the signal localized in time and frequency and serves as input to an artificial neural network. A pooled set of EEG data together with the corresponding manual evaluati…
Dissociable contributions of left and right dorsolateral prefrontal cortex in planning.
2010
It is well established that the mid-dorsolateral prefrontal cortex (dlPFC) plays a critical role in planning. Neuroimaging studies have yielded predominantly bilateral dlPFC activations, but the existence and nature of functionally specific contributions of left and right dlPFC have remained elusive. In recent experiments, 2 independent parameters have been identified which substantially determine planning: 1) the degree of interdependence between consecutive steps (search depth) and 2) the degree to which the configuration of the goal state renders the order of single steps either clearly evident or ambiguous (goal hierarchy). Thus, search depth affects the actual mental generation and eva…
Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius
2008
Recent in vitro and simulation studies have shown that guided waves measured at low ultrasound frequencies (f=200 kHz) can characterize both material properties and geometry of the cortical bone wall. In particular, a method for an accurate cortical thickness estimation from ultrasound velocity data has been presented. The clinical application remains, however, a challenge as the impact of a layer of soft tissue on top of the bone is not yet well established, and this layer is expected to affect the dispersion and relative intensities of guided modes. The present study is focused on the theoretical modeling of the impact of an overlying soft tissue. A semianalytical method and finite-differ…
Efficacy of 3 toothbrush treatments on plaque removal in orthodontic patients assessed with digital plaque imaging: a randomized controlled trial.
2013
Good oral hygiene is a challenge for orthodontic patients because food readily becomes trapped around the brackets and under the archwires, and appliances are an obstruction to mechanical brushing. The purpose of this study was to compare plaque removal efficacy of 3 toothbrush treatments in orthodontic subjects.This was a replicate-use, single-brushing, 3-treatment, examiner-blind, randomized, 6-period crossover study with washout periods of approximately 24 hours between visits. Forty-six adolescent and young adult patients with fixed orthodontics from a university clinic in Germany were randomized, based on computer-generated randomization, to 1 of 3 treatments: (1) oscillating-rotating …
Efficacy of single-source rapid kV-switching dual-energy CT for characterization of non-uric acid renal stones: a prospective ex vivo study using ant…
2019
Purpose To investigate the accuracy of rapid kV-switching single-source dual-energy computed tomography (rsDECT) for prediction of classes of non-uric-acid stones. Materials and methods Non-uric-acid renal stones retrieved via percutaneous nephrolithotomy were prospectively collected between January 2017 and February 2018 in a single institution. Only stones >= 5 mm and with pure composition (i.e., >= 80% composed of one component) were included. Stone composition was determined using Fourier Transform Infrared Spectroscopy. The stones were scanned in 32-cm-wide anthropomorphic whole-body phantom using rsDECT. The effective atomic number (Zeff), the attenuation at 40 keV (HU40), 70 ke…