Search results for " Conduction"

showing 10 items of 373 documents

Plantar flexor activation capacity and H reflex in older adults: adaptations to strength training.

2002

The purpose of this study was to investigate whether the voluntary neural drive and the excitability of the reflex arc could be modulated by training, even in old age. To this aim, the effects of a 16-wk strengthening program on plantar flexor voluntary activation (VA) and on the maximum Hoffman reflex (Hmax)-to-maximum M wave (Mmax) ratio were investigated in 14 elderly men (65–80 yr). After training, isometric maximum voluntary contraction (MVC) increased by 18% ( P < 0.05) and weight-lifting ability by 24% ( P < 0.001). Twitch contraction time decreased by 8% ( P < 0.01), but no changes in half relaxation time and in peak twitch torque were observed. The VA, assessed by twitch …

MaleVolitionAgingPhysiologydegenerationadaptationIsometric exerciseNerve conduction velocityhuman experimentH-ReflexTriceps surae muscleTwitch interpolationadaptation; aged; aging; article; controlled study; degeneration; excitability; exercise; Hoffmann reflex; human; human experiment; male; muscle contraction; muscle isometric contraction; muscle relaxation; muscle twitch; nerve conduction; normal human; plantaris muscle; priority journal; reflex arc; strength; torque; training; voluntary movement; Aging; Exercise; Triceps surae; Twitch interpolationAged 80 and overtrainingvoluntary movementReflex arcarticlereflex arcmusculoskeletal systemAdaptation Physiologicalmuscle twitchmedicine.anatomical_structuremuscle relaxationpriority journalCardiologyTriceps suraemedicine.symptomstrengthMuscle contractionMuscle Contractionmedicine.medical_specialtyWeight Liftingplantaris muscleStrength trainingPhysical exercisePhysical medicine and rehabilitationPhysiology (medical)Internal medicineexcitabilitymedicineHumanscontrolled studyhumannormal humanMuscle SkeletalExercisenerve conductionAgedmuscle isometric contractionbusiness.industrybody regionsHoffmann reflexTorqueH-reflexbusinessJournal of applied physiology (Bethesda, Md. : 1985)
researchProduct

The gene encoding ganglioside-induced differentiation-associated protein 1 is mutated in axonal Charcot-Marie-Tooth type 4A disease

2001

We identified three distinct mutations and six mutant alleles in GDAP1 in three families with axonal Charcot-Marie-Tooth (CMT) neuropathy and vocal cord paresis, which were previously linked to the CMT4A locus on chromosome 8q21.1. These results establish the molecular etiology of CMT4A (MIM 214400) and suggest that it may be associated with both axonal and demyelinating phenotypes.

Malecongenital hereditary and neonatal diseases and abnormalitiesDNA Mutational AnalysisMolecular Sequence DataMutantMutation MissenseNeural ConductionGenes RecessiveNerve Tissue ProteinsLocus (genetics)BiologyPolymerase Chain ReactionFrameshift mutationCharcot-Marie-Tooth DiseaseGeneticsHumansMissense mutationAge of OnsetAlleleChildFrameshift MutationGeneAllelesGeneticsBrainInfantExonsAnatomyPhenotypeAxonsPedigreeAmino Acid SubstitutionHaplotypesSpinal CordCodon NonsenseSpainChild PreschoolFemaleLod ScoreVocal cord paresisChromosomes Human Pair 8Demyelinating DiseasesNature Genetics
researchProduct

The total absence of atrial automaticity in a child with sinus node dysfunction

2007

Background A routine sports evaluation identified constant alternation between a junctional and idioventricular rhythm in a 9-year-old child. During exercise testing, electrography demonstrated that the child was in junctional rhythm without any apparent P waves, and had a reduced increase in heart rate. Endocardial atrial pacing captured the atrium and demonstrated that atrioventricular conduction was normal, but the recovery time of the ectopic rhythm was very long. Three-dimensional electrophysiological mapping revealed 1:1 retrograde homogeneous conduction through the right atrium. Investigations Electrocardiography, Holter monitoring, echocardiography, exercise stress testing, atrial p…

Malemedicine.medical_specialtyAccelerated idioventricular rhythmElectrocardiographyHeart Conduction SystemHeart RateInternal medicineHeart ratemedicineHumanscardiovascular diseasesHeart AtriaAtrium (heart)ChildSinoatrial Nodemedicine.diagnostic_testSinoatrial nodebusiness.industryGeneral Medicinemedicine.diseaseIdioventricular rhythmmedicine.anatomical_structureAnesthesiacardiovascular systemCardiologyElectrocardiography AmbulatoryElectrical conduction system of the heartCardiology and Cardiovascular MedicinebusinessElectrophysiologic Techniques CardiacElectrocardiographyJunctional rhythmAccelerated Idioventricular Rhythm
researchProduct

Inner ear function in children with Fabry disease

2007

Aim: The prevalence of hearing loss in patients with Fabry disease is still uncertain. This paper examines hearing loss in a group of young patients with Fabry disease. Methods: A clinical ear nose and throat examination,pure-tone air and bone conduction audiometry, speech audiometry and middle ear testing (tympanometry and acoustic reflex testing) were carried out in four girls and two boys with Fabry disease (age, 7-17 years), receiving enzyme replacement therapy (ERT). Results: None of the patients complained of a hearing disorder or suffered from hearing loss. Three female patients reported tinnitus; however, this was not reported as being a problem. One boy reported tinnitus for the fi…

Malemedicine.medical_specialtyAdolescentHearing lossAudiologyTinnitusBone conductionotorhinolaryngologic diseasesmedicineHumansChildmedicine.diagnostic_testbusiness.industryGeneral MedicineEnzyme replacement therapyTympanometrymedicine.diseaseFabry diseaseHearing disorderPediatrics Perinatology and Child HealthFabry DiseaseFemalemedicine.symptomAudiometrybusinessTinnitusActa Paediatrica
researchProduct

Biomechanics of sprint running. A review.

1992

Understanding of biomechanical factors in sprint running is useful because of their critical value to performance. Some variables measured in distance running are also important in sprint running. Significant factors include: reaction time, technique, electromyographic (EMG) activity, force production, neural factors and muscle structure. Although various methodologies have been used, results are clear and conclusions can be made. The reaction time of good athletes is short, but it does not correlate with performance levels. Sprint technique has been well analysed during acceleration, constant velocity and deceleration of the velocity curve. At the beginning of the sprint run, it is importa…

Malemedicine.medical_specialtyComputer scienceeducationAccelerationNeural ConductionPhysical Therapy Sports Therapy and RehabilitationElectromyographyPropulsionRunningAccelerationmedicineHumansOrthopedics and Sports MedicineSimulationmedicine.diagnostic_testElectromyographyWork (physics)BiomechanicsBiomechanical PhenomenaSprintDragPhysical therapyFemaleBiomechanics of sprint runninghuman activitiesSports medicine (Auckland, N.Z.)
researchProduct

Endoscopic carpal tunnel release: results with special consideration to possible complications.

2000

Single-portal endoscopic carpal tunnel release (Agee technique) was carried out in 148 patients. Of these, 100 were examined clinically and electrophysiologically 1 day before surgery and 1 and 3 months thereafter. Ten patients experienced transient ulnar neuropraxia and two patients complained postoperatively of intense pain in the middle and ring fingers. Three patients suffered residual symptoms. In one of these an incomplete release of the distal portion of the retinaculum flexorum was suspected and later confirmed by magnetic resonance imaging. Another patient had applied for pension due to problems associated with a vertebral fracture in addition to his carpal tunnel symptoms. A third…

Malemedicine.medical_specialtyDecompressionNeural ConductionRetinaculumUlnar ArteryPostoperative ComplicationsTendon InjuriesMedicineHumansOrthopedics and Sports MedicineCarpal tunnelUlnar NerveRupturemedicine.diagnostic_testbusiness.industryMagnetic resonance imagingEndoscopyMiddle AgedDecompression SurgicalCarpal Tunnel SyndromeEndoscopic carpal tunnel releaseTendonSurgeryMedian Nervebody regionsmedicine.anatomical_structureOrthopedic surgerySurgeryFemalebusinessComplicationKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA
researchProduct

Nerve conduction velocity and circulating immunocomplexes in type 1 diabetic children.

1991

There is evidence from several laboratories of an increased prevalence of circulating immuno-complexes (CIC) in diabetic patients. It has also been suggested that CIC are pathogenetically related to chronic diabetic complications. The aim of this study was to assess peripheral nerve function in children with Type 1 diabetes and to evaluate the relationship between the neurophysiological abnormalities and the possible presence of CIC. The investigation was carried out in 25 Type 1 diabetic patients ranging in age from 7-19 years and in 20 normal controls. Neurophysiological assessment was performed to evaluate motor and sensory conduction velocity on median and tibial nerves. IgG-CIC were de…

Malemedicine.medical_specialtyDiabetic neuropathyAdolescentSensory Receptor CellsNeural ConductionSensory systemAntigen-Antibody ComplexGastroenterologyNerve conduction velocityPathogenesisDiabetic NeuropathiesInternal medicineElectroneuronographymedicineReaction TimeHumansPeripheral NervesChildMotor NeuronsType 1 diabetesbusiness.industryGeneral Medicinemedicine.diseaseEndocrinologyDiabetes Mellitus Type 1NeurologyFemaleNeurology (clinical)ComplicationbusinessPolyneuropathyActa neurologica Scandinavica
researchProduct

Initial experience with the Sophono Alpha 1 osseointegrated implant.

2013

In the last several years, bone anchored hearing aids have proven to be useful in treating conductive and mixed unilateral or bilateral hearing loss, as well as for sensorineural unilateral hearing loss. The Sophono Alpha 1 model has the advantage of not requiring an abutment, with it being coupled by magnetism instead. We report the cases of 3 infants with congenital malformations of external and middle ear. Audiometry showed conductive hearing loss. All 3 patients were implanted with Alpha 1 model (Sophono). Patients evolved satisfactorily. After 30 days we applied the processor and the control audiometry showed a marked improvement of hearing thresholds, although without a complete closu…

Malemedicine.medical_specialtyHearing Loss ConductiveOsseointegrationHearing AidsOsseointegrationotorhinolaryngologic diseasesmedicineHumansAbnormalities MultipleChildmedicine.diagnostic_testbusiness.industryBone-anchored hearing aidEarGeneral MedicineProstheses and Implantsmedicine.diseaseConductive hearing lossSurgerymedicine.anatomical_structureMiddle earMagnetsFemaleImplantUnilateral hearing lossAudiometrybusinessAbutment (dentistry)Bone ConductionEar CanalActa otorrinolaringologica espanola
researchProduct

First Experiences With the Ponto⢢ SuperPower Osseointegrated Device

2018

Osseointegrated hearing devices Power and SuperPower present indications for bone thresholds of 55 and 65 dB respectively. We conducted a prospective observational study of a series of six cases with mixed hearing loss for whom implantation of the DAO Ponto™ Super-Power was performed. Tonal and verbal evaluations without and with background noise (HINTS) were performed prior to implantation and six months after adaptation. All the participants showed improvement in tonal and verbal results, varying according to the degree of contralateral hearing loss. The verbal results with background noise were noteworthy, where most of the patients obtained a signal-to-noise ratio between 2 and 4 dB. Th…

Malemedicine.medical_specialtyHearing lossmedia_common.quotation_subjectSignal-To-Noise RatioAudiologybehavioral disciplines and activities01 natural sciences03 medical and health sciencesHearing Aids0302 clinical medicineBone conductionQuality of lifeOsseointegrationSurveys and QuestionnairesPerception0103 physical sciencesmedicineHumansProspective Studies030223 otorhinolaryngology010301 acousticsHearing Loss Mixed Conductive-Sensorineuralmedia_commonmedicine.diagnostic_testbusiness.industryAuditory ThresholdEquipment DesignProstheses and ImplantsGeneral MedicineMiddle Agedmedicine.diseaseConductive hearing lossTreatment OutcomePatient SatisfactionQuality of LifeFemaleObservational studymedicine.symptomAudiometrybusinessBone ConductionActa Otorrinolaringologica (English Edition)
researchProduct

Impaired cortico-bulbar tract function in dysarthria due to hemispheric stroke. Functional testing using transcranial magnetic stimulation.

1997

We investigated cortico-lingual and cortico-orofacial tract function utilizing transcranial magnetic stimulation in 18 consecutive patients with dysarthria due to hemispheric stroke. Delayed responses (conduction time > mean + 2.5 SD of that of 43 controls) or absent responses were considered abnormal. In all patients, motor-cortex stimulation of the lesion side demonstrated absent (13 patients) or delayed (five patients) responses to the tongue bilaterally (17 patients) or unilaterally (one patient). In 14 patients the contralateral orofacial responses were either absent (13 patients) or delayed (one patient). According to the electrophysiological findings, all lesions revealed by CT or MR…

Malemedicine.medical_specialtyInternal capsulemedicine.medical_treatmentNeural ConductionDysarthriaTongueInternal medicinemedicineHumansStrokeAgedAged 80 and overPyramidal tractsCerebral infarctionDysarthriaMotor CortexCerebral InfarctionMiddle Agedmedicine.diseaseTranscranial Magnetic StimulationElectric StimulationSurgeryTranscranial magnetic stimulationCerebrovascular DisordersFacial Nervemedicine.anatomical_structureCorticospinal tractCardiologyFemaleNeurology (clinical)medicine.symptomPsychologyMotor cortexBrain : a journal of neurology
researchProduct