Search results for " Cooling"
showing 10 items of 278 documents
The Nukiyama Curve in Water Spray Cooling: its Derivation from Temperature-Time Histories and its Dependence on the Quantities that Characterize Drop…
2007
Abstract Heat transfer from hot aluminium walls to cold water sprays was investigated. The method used was the transient two-side symmetric cooling of a planar aluminium target, previously heated to temperatures of up to 750 K, by twin sprays issuing from full-cone swirl spray nozzles of various gauge. The target’s mid-plane temperature was recorded during the cooling transient by thin-foil K thermocouples and a high-frequency data acquisition system. In order to determine the wall temperature Tw, the wall heat flux q w ″ and the q w ″ - T w heat transfer (Nukiyama) curve, two different approaches were used: the first was based on the solution of an inverse heat conduction problem, the seco…
Heat and work fluxes in thermoelectric coolers
2021
Abstract Thermodynamics considers heat and work as the observables of energy. Then, in a non-equilibrium process, the fluxes of heat, work and energy are related. The expressions for the heat and energy flux densities are well known; although several conventions have been adopted. The work flux density defined from the heat and energy flux densities can be very useful in describing the energy balance when chosen to emphasize observable quantities. This paper discusses the advantages of the use of the conduction heat flux density given by Fourier’s law and a work flux density defined from it. As a case study, heat and work fluxes are evaluated in the elements of a thermoelectric cooler using…
Mapping Seasonal Variability of Buildings Electricity Demand profiles in Mediterranean Small Islands
2023
In communities with a high tourist influx and warm climate, such as Mediterranean small islands, the energy demands for space cooling and domestic hot water are expected to significantly increase during summer. Considering the current energy context, for succeeding energy transition and reducing the dependency on not endogenous fossil fuels, it is paramount to increase the deployment of renewable sources of energy, especially wind and solar which, however, are aleatory and unpredictable. Hence, to reduce the high costs for energy supply in these contexts, the analysis of the variation of energy consumption is fundamental. Moreover, mapping the spatial distribution of energy profiles can be …
Femtosecond time resolved coherent anti-Stokes Raman spectroscopy: Experiment and modelization of speed memory effects on H2-N2 mixtures in the colli…
2005
194317; With the aim of temperature diagnostic, femtosecond time-resolved CARS (coherent anti-Stokes Raman spectroscopy) is applied to probe H2 in H2-N2 mixtures. In a first part, a Lorentzian profile is used to model the femtosecond CARS response. A difference between the experimental broadening and the expected one is observed in the collision regime. The observed broadening increases strongly in an inhomogeneous way with respect to the perturber concentration. This is of considerable importance for temperature measurements. In a second part, we show that in the collision regime, this inhomogeneous broadening is due to the speed dependence of the collisional parameters and the memory effe…
Improving energy efficiency of commercial buildings by Combined Heat Cooling and Power plants
2020
Abstract Commercial buildings play a key-role in the energy consumption of the building sectors. Recent statistics have shown that as the number of commercial buildings is continuously increasing, their effects on energy consumption are expected to grow. These buildings are characterized by high energy demand mainly due to lighting and HVAC requirements. Rooms of energy saving exist by considering that: (i) electricity demands and HVAC requirements occur simultaneously during the day and (ii) both demands are currently satisfied by using separate energy systems. It is apparent that the adoption of polygeneration systems could represent a valid solution to achieve energy savings. To this aim…
The Global Stratotype Section and Point (GSSP) of the Serravallian Stage (Middle Miocene)
2009
The Global Stratotype Section and Point (GSSP) for the Base of the Serravallian Stage (Middle Miocene) is defined in the Ras il Pellegrin section located in the coastal cliffs along the Fomm Ir-Rih Bay on the west coast of Malta (35°54'50"N, 14°20'10"E). The GSSP is at the base of the Blue Clay Formation (i.e., top of the transitional bed of the uppermost Globigerina Limestone). This boundary between the Langhian and Serravallian stages coincides with the end of the major Mi-3b global cooling step in the oxygen isotopes and reflects a major increase in Antarctic ice volume, marking the end of the Middle Miocene climate transition and the Earth's transformation into an "Icehouse" climate sta…
Solar heating and cooling systems versus conventional systems assisted by photovoltaic: Application of a simplified LCA tool
2016
Abstract Life Cycle Assessment (LCA) is an effective methodology to assess the energy and environmental impacts of energy systems during their life cycle, including manufacturing, operation and end-of-life. The aim of the paper is the application of a simplified LCA tool, developed in the framework of the International Energy Agency Solar Heating and Cooling Task 48, for comparing different typologies of solar assisted heating and cooling systems. In detail, solar thermal heating and cooling systems located in Palermo (southern Italy) and in Zurich (Switzerland) were compared with conventional systems assisted by grid connected and stand-alone photovoltaic plants. A validation of the tool w…
Efficiency improvement of a ground coupled heat pump system from energy management
2011
The installed capacity of an air conditioning system is usually higher than the average cooling or heating demand along the year. So, most of the time, the system is working under its actual capacity. In this contribution, we study the way to improve the efficiency of a ground coupled heat pump air conditioning system by adapting its produced thermal energy to the actual thermal demand. For this purpose, an air conditioning system composed by a ground coupled heat pump and a central fan coil linked to an office located in a cooling dominated area was simulated, and a new management strategy aiming to diminish electrical consumption was developed under the basic constraint that comfort requi…
On the observability of T Tauri accretion shocks in the X-ray band
2010
Context. High resolution X-ray observations of classical T Tauri stars (CTTSs) show a soft X-ray excess due to high density plasma (n_e=10^11-10^13 cm^-3). This emission has been attributed to shock-heated accreting material impacting onto the stellar surface. Aims. We investigate the observability of the shock-heated accreting material in the X-ray band as a function of the accretion stream properties (velocity, density, and metal abundance) in the case of plasma-beta<<1 in the post-shock zone. Methods. We use a 1-D hydrodynamic model describing the impact of an accretion stream onto the chromosphere, including the effects of radiative cooling, gravity and thermal conduction. We expl…
Observability and diagnostics in the X-ray band of shock-cloud interactions in supernova remnants
2010
X-ray emitting features originating from the interaction of supernova shock waves with small interstellar gas clouds are revealed in many X-ray observations of evolved supernova remnants (e.g. Cygnus Loop and Vela), but their interpretation is not straightforward. We develop a self-consistent method for the analysis and interpretation of shock-cloud interactions in middle-aged supernova remnants, which can provide the key parameters of the system and the role of relevant physical effects like the thermal conduction, without the need to run ad-hoc numerical simulations and to bother of morphology details. We explore all the possible values of the shock speed and cloud density contrast releva…