Search results for " DOSIMETRY"

showing 10 items of 120 documents

Testing and linearity calibration of films of phenol compounds exposed to thermal neutron field for EPR dosimetry

2015

This paper reports the preliminary results obtained by Electron Paramagnetic Resonance (EPR) measurements on films of IRGANOX® 1076 phenols with and without low content (5% by weight) of gadolinium oxide (Gd2O3) exposed in the thermal column of the Triga Mark II reactor of LENA (Laboratorio Energia Nucleare Applicata) of Pavia (Italy). Thanks to their size, the phenolic films here presented are good devices for the dosimetry of beams with high dose gradient and which require accurate knowledge of the precise dose delivered. The dependence of EPR signal as function of neutron dose was investigated in the fluence range between 10(11) cm(-2) and 10(14) cm(-2). Linearity of EPR response was fou…

Settore ING-IND/20 - Misure E Strumentazione NucleariAnalytical chemistryGadoliniumFluenceTRIGAlaw.inventionNCT dosimetrychemistry.chemical_compoundPhenolslawCalibrationPhenolDosimetryIrradiationElectron paramagnetic resonanceNeutron beamNeutronsRadiationPhenolSettore ING-IND/18 - Fisica Dei Reattori NucleariSettore FIS/01 - Fisica SperimentaleElectron Spin Resonance SpectroscopyNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Electron Paramagnetic ResonancechemistryCalibrationNuclear chemistry
researchProduct

Dosimetry of Mainz reactors by means of ESR dosimetry with alanine added with gadolinium

2014

Settore ING-IND/20 - Misure E Strumentazione NucleariESR dosimetry Alanine Gadolinium NCTSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Gel dosimeters for medical physics applications

2015

Gel dosimeters for three-dimensional mapping of radiotherapy doses were introduced at Yale University in the mid-1980’s. Soon after, R&D in this field also started in Italy. Early work was done at the Istituto Superiore di Sanità, and at the Universities of Pisa and Milan. Several institutes now collaborate on this topic with support from the Italian Ministry for University and Research (MIUR) through Grant PRIN SNALEM2010 “Development and application of new materials for ionizing radiation dosimetry”. This presentation describes this research, which aims at developing new formulations of hydrogel matrices with improved characteristics of stability, sensitivity and spatial resolution co…

Settore ING-IND/20 - Misure E Strumentazione NucleariFricke gel PRIN DosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Investigation of relaxation times of irradiated Fricke gels by means of nuclear magnetic resonance relaxometry

2016

Fricke gel dosimeters are ideal candidates to provide 3D maps of dose distributions and are particularly useful in the plann ing and verification phase of radiotherapy treatments. One of the most effective experimental techniques to reconstruct dose maps is magnetic resonance imaging (MRI). This measures th e nuclear relaxation times variations induced by irradiation. In this work, we analyzed Fricke gels with and without Xylenol Orange by means of a single side-NMR relaxometer (which is abl e to provide information on both relaxation relaxation times T1 and T2 and is mainly used in the field of diagnostics for Cultural Heritage [1-2] to perform porosimetry meaurements). Our goal was to per…

Settore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleFricke gel Dosimetry NMR MRI AgaroseSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

EPR ANALYSIS OF ALANINE WITH GADOLINIUM FOR DOSIMETRY AT TRIGA MARK II REACTOR OF MAINZ

2015

Negli ultimi anni il crescente interesse verso la radioterapia a cattura neutronica (internazionalmente nota come Neutron Capture Therapy - NCT) per il trattamento di neoplasie ha stimolato diverse attività di ricerca finalizzate alla caratterizzazione del fascio utilizzato e all'ottimizzazione delle procedure radioterapiche. La corretta riuscita del trattamento NCT e il monitoraggio della dose impartita non possono prescindere dalla valutazione delle varie componenti del fascio impiegato (neutronica e fotonica). Infatti, durante le procedure di moderazione dei neutroni, si verifica la produzione di fotoni e la stima dei rischi a cui sono soggetti i tessuti sani sottoposti al campo misto ne…

Settore ING-IND/20 - Misure E Strumentazione NucleariSettore ING-IND/18 - Fisica Dei Reattori NucleariSettore FIS/01 - Fisica SperimentaleMAINZ REACTOR DOSIMETRY ALANINE ESR EPR FLUKA NCT GADOLINIUMSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Novel dosimetric gels for three-dimensional dose mapping in radiotherapy

2016

One of the most recent and promising developments for radiotherapy (RT) dosimetry was the introduction of 3D radiation- sensitive gels. The gels are tissue equivalent, so they also serve as a phantom, and their response is largely independent of rad iation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gels) . These gels suffer from spontaneous-oxidation and diffusion of ferric ions after irradiation; the latter is significantly reduced by chelating agents such as xylenol orange (XO) (Fricke-XO gels) [2]. Other formulations consist of dispersed monomers, and rely on radiation-induced cross-…

Settore ING-IND/24 - Principi Di Ingegneria ChimicaSettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleGel DosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Settore CHIM/02 - Chimica Fisica
researchProduct

EPR DOSIMETRY WITH ALANINE FOR TOTAL BODY IRRADIATION USING AN ANTHROPOMORPHIC PHANTOM

2016

The Total Body Irradiation (TBI) is a radiation therapy technique widely used in clinical hemato-oncological treatment of patients that underwent bone marrow transplantation or peripheral stem cell transplantation. Typically, the administration of TBI treatment provides irradiations in 3 consecu-tive days with a double daily fractionation, although other dose fractionation modes have been widely adopted in the clinic procedures. Although this tech-nique allows to irradiate the whole body from head to toes, it has some limitations such as the lack of homogeneity of the dose distribution (which can show varia-tions of 20% in the different areas), irradiation of critical organs such as lungs, …

TBI ESR EPR alanine dosimetrySettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

TL dose reconstruction in watch glasses exposed to photon, electron and proton beams

2010

Thermoluminescence dosimetry watch glasses photons electrons protonsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

The response behaviour of LiF:Mg,Cu,P thermoluminescence dosimeters to high-energy electron beams used in radiotherapy

1995

To ensure the effectiveness of radiation-therapy treatments, both in-phantom and in-patient reliable dose measurements are required. Thermoluminescence dosimeters are used commonly for both applications. Among the various available materials, the relatively new LiF:Mg,Cu,P phosphor is a suitable candidate for quality control of in vivo dosimetry in electron-beam therapy. The response behaviour of LiF:Mg,Cu,P chips to 6-21 MeV electron beams used in radiotherapy was studied. Batch homogeneity, dose linearity, sensitivity change after use, dose and dose-rate response, energy dependence and fading characteristics were investigated. The contribution from each factor to the overall uncertainty i…

Time FactorsDosimeterMaterials scienceRadiological and Ultrasound Technologybusiness.industryRadiochemistryDose profilePhosphorElectronModels TheoreticalThermoluminescenceRadiotherapy High-EnergyThermoluminescent DosimetryCathode rayHumansDosimetryThermoluminescent DosimetryRadiology Nuclear Medicine and imagingNuclear medicinebusinessPhysics in Medicine and Biology
researchProduct

EPR/alanine dosimetry for verification in Helical Tomotherapy Stereotactic Radiosurgery (HTSRS) treatments

2018

Introduction Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. In this study the accuracy of the dose delivered in SRS by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test using alanine pellets and gafchromic films. Methods Dose verifications were made using alanine dosimeters placed in an antropomorphic head phantom (Alderson Rando Phantom) under different treatment conditions in case of both single and multiple brain tumors. 1.25mm slice kVCT scan of the phantom was used to generate SRS plans on the TomoTherapy Plann…

Tomotherapy Dosimetry EPR AlanineSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct