Search results for " Depth"
showing 10 items of 235 documents
Influence of a Crosslinker Containing an Azo Group on the Actuation Properties of a Photoactuating LCE System
2016
Photoactuating liquid crystalline elastomers (LCE) are promising candidates for an application as artificial muscles in microdevices. In this work, we demonstrate that by optimizing (1) the illumination conditions and (2) the mixture of azo monomer and azo crosslinker, thick films of an all-azo LCE can be prepared, which show a strong length change without bending during photoactuation. This becomes possible by working with white light (about 440 nm), whose absorption is low, leading to a large penetration depth. By adding an azo crosslinker to a previously prepared system, several improvements of the actuation properties—like a stronger photoactuation at lower operational temperatures—coul…
Statistical prediction of corrosion front penetration
1997
A statistical method to predict the stochastic evolution of corrosion fronts has been developed. The method is based on recording material loss and maximum front depth. In this paper we introduce the method and test its applicability. In the absence of experimental data we use simulation data from a three-dimensional corrosion model for this test. The corrosion model simulates localized breakdown of a protective oxide layer, hydrolysis of corrosion product and repassivation of the exposed surface. In the long time limit of the model, pits tend to coalesce. For different model parameters the model reproduces corrosion patterns observed in experiment. The statistical prediction method is base…
Comprehensive formulation of temperature-dependent dispersion of optical materials: illustration with case of temperature tuning of a mid-IR HgGa_2S_…
2009
The temperature dependence of refractive indices of optical materials is characterized in this work by what we call their normalized thermo-optic coefficients. These are determined experimentally through interferometric measurements of thermal expansion and of changes in optical thickness at a few laser wavelengths as function of temperature. A suitable vectorial formalism applied to these data allows predicting the thermal evolution of the refractive index all over the useful range of transparency. The validity and reliability of our methodology is demonstrated through temperature tuning of a mid-IR HgGa2S4 optical parametric oscillator (OPO) pumped at 1.0642 μm by a Nd:YAG laser. Measured…
Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions
2016
Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…
Dependence of the Optical Constant Parameters of p-Toluene Sulfonic Acid-Doped Polyaniline and Its Composites on Dispersion Solvents
2020
The optical constants of Para-Toluene sulfonic acid-doped polyaniline (PANI), PANIchitosan composites, PANI-reduced graphene-oxide composites and a ternary composite comprising of PANI, chitosan and reduced graphene-oxide dispersed in diluted p-toluene sulfonic acid (PTSA) solution and N-Methyl-2-Pyrrolidone (NMP) solvent have been evaluated and compared. The optical constant values were extracted from the absorbance spectra of thin layers of the respective samples. The potential utilization of the materials as the active sensing materials of surface plasmon resonance biosensors has also been assessed in terms of the estimated value of the penetration depth through a dielectric medium. The …
Explicit equations for uniform flow depth
2017
Conventional approach in uniform open channel flow is to express the resistance coefficient in the Manning, Darcy-Weisbach or Chezy form. However, for practical cross-sections, including rectangular and trapezoidal ones, the governing equation is implicit in the uniform water depth. For these sections the water depth, corresponding to known values of the flow discharge, slope channel and resistance coefficient, is presently obtained by trial and error procedure. In this paper exact analytical solutions of uniform flow depth for rectangular and trapezoidal section have been obtained in the form of fast converging power series.
Fuzzified Game Tree Search – Precision vs Speed
2012
Most game tree search algorithms consider finding the optimal move. That is, given an evaluation function they guarantee that selected move will be the best according to it. However, in practice most evaluation functions are themselves approximations and cannot be considered "optimal". Besides, we might be satisfied with nearly optimal solution if it gives us a considerable performance improvement. In this paper we present the approximation based implementations of the fuzzified game tree search algorithm. The paradigm of the algorithm allows us to efficiently find nearly optimal solutions so we can choose the "target quality" of the search with arbitrary precision --- either it is 100% (pr…
First evaluation of the simultaneous SMOS and ELBARA-II observations in the Mediterranean region
2012
Abstract The SMOS (Soil Moisture and Ocean Salinity) mission was launched on November 2, 2009. Over the land surfaces, simultaneous retrievals of surface soil moisture (SM) and vegetation characteristics made from the multi-angular and dual polarization SMOS observations are now available from Level-2 (L2) products delivered by the European Space Agency (ESA). Therefore, first analyses evaluating the SMOS observations in terms of Brightness Temperatures (TB) and L2 products (SM and vegetation optical depth TAU) can be carried out over several calibration/validation (cal/val) sites selected by ESA over all continents. This study is based on SMOS observations and in situ measurements carried …
The SMOS mediterranean ecosystem L-band characterisation experiment (MELBEX) over natural shrubs
2010
10 páginas, 5 figuras, 7 tablas.
Hyperspectral solar spectral measurements and applications
2007
Measurements of hyperspectral solar irradiance from aircraft and satellite are applied to a variety of cloud and aerosol remote sensing, and radiative energy budget applications.