Search results for " Doppler"

showing 10 items of 373 documents

Reduced recanalization rates of the great saphenous vein after endovenous laser treatment with increased energy dosing: Definition of a threshold for…

2006

Background Recent reports indicated a correlation between the amount of energy released during endovenous laser treatment (ELT) of the great saphenous vein (GSV) and the success and durability of the procedure. Our objective was to analyze the influence of increased energy dosing on immediate occlusion and recanalization rates after ELT of the GSV. Methods GSVs were treated with either 15 or 30 W of laser power by using a 940-nm diode laser with continuous fiber pullback and tumescent local anesthesia. Patients were followed up prospectively with duplex ultrasonography at day 1 and at 1, 3, 6, and 12 months. Results A total of 114 GSVs were treated with 15 W, and 149 GSVs were treated with …

AdultMalemedicine.medical_specialtyDuplex ultrasonographyTime FactorsAdolescentmedicine.medical_treatmentAngioscopyOcclusionmedicineHumansSaphenous VeinLocal anesthesiaProspective StudiesDosingVeinAgedAged 80 and overUltrasonography Doppler DuplexLaser Coagulationmedicine.diagnostic_testbusiness.industryGreat saphenous veinEndovenous laser treatmentMiddle AgedAngioscopySurgeryTreatment Outcomemedicine.anatomical_structureVenous InsufficiencyChronic DiseaseFemaleSurgeryCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Vascular Surgery
researchProduct

Pilot study for the evaluation of morphological and functional changes in retinal blood flow in patients with insulin resistance and/or type 2 diabet…

2012

Background: The aim of this study was to investigate early morphological and functional pathology in the retinal micro-circulation in patients with insulin resistance and/or type 2 diabetes mellitus (T2DM). Methods: Fifty-four subjects, without features of retinopathy under ophthalmological investigation, were recruited for study participation and were classifed into three study groups according to their metabolic staging: (1) Group C comprised nondiabetic, insulin-sensitive subjects with a BMI <28kg/m2; (2) Group IR comprised nondiabetic, insulin-resistant, obese subjects with a BMI ≥28 kg/m2; and (3) Group DM comprised patients with manifested T2DM. Retinal microvascular blood flow was…

AdultMalemedicine.medical_specialtyEndocrinology Diabetes and MetabolismBiomedical EngineeringBioengineeringPilot Projectschemistry.chemical_compoundInsulin resistanceRetinal DiseasesInternal medicineOphthalmologyDiabetes mellitusInternal MedicineLaser-Doppler FlowmetryMedicineHumansObesityFluorescein AngiographyAgedDiabetic Retinopathymedicine.diagnostic_testbusiness.industryType 2 Diabetes MellitusRetinal VesselsRetinalBlood flowLaser Doppler velocimetryMiddle Agedmedicine.diseaseFluorescein angiographyEndocrinologyCross-Sectional StudiesEarly DiagnosischemistryDiabetes Mellitus Type 2Regional Blood FlowFemaleOriginal ArticleInsulin ResistancebusinessRetinopathyJournal of diabetes science and technology
researchProduct

Optimal duration of treatment in surgical patients with calf venous thrombosis involving one or more veins.

2006

The aim of this study was to evaluate different durations of treatment in patients with calf venous thrombosis (CVT) involving 1 or more deep veins. The authors studied 2 groups of patients with postsurgical CVT diagnosed by echo-color Doppler. The first group consisted of 68 patients with CVT involving a single vein, and the second group consisted of 124 patients with CVT involving 2 or more veins. Immediately after diagnosis, all patients were treated with nadroparin calcium and sodium warfarin. Heparin treatment was withdrawn after 5–6 days of treatment, when the international normalized ratio (INR) was stabilized between 2 and 3. Each group was divided into 2 subgroups receiving antico…

AdultMalemedicine.medical_specialtyFemoral vein030204 cardiovascular system & hematologyDrug Administration ScheduleLesion03 medical and health sciences0302 clinical medicinePostoperative ComplicationsMedicineHumans030212 general & internal medicineThrombusUltrasonography Doppler ColorVeinAgedVenous ThrombosisLegbusiness.industryAnticoagulantsNadroparinHeparinMiddle Agedmedicine.diseaseNadroparin calciumSurgeryVenous thrombosismedicine.anatomical_structureAnesthesiacardiovascular systemFemaleWarfarinmedicine.symptomCardiology and Cardiovascular MedicinebusinessSurgical patientsmedicine.drugAngiology
researchProduct

Left ventricular function analyzed by Doppler and echocardiographic methods in short-term hypothyroidism

1995

Abstract In conclusion, a significant reversible decrease in contractility and an impaired diastolic relaxation was demonstrated in patients with short-term hypothyroidism. This must be considered in patients with preexisting heart disease.

AdultMalemedicine.medical_specialtyHeart diseaseDiastoleVentricular Function LeftContractilitysymbols.namesakeHypothyroidismInternal medicinemedicineHumansIn patientSystoleVentricular functionbusiness.industryMiddle Agedmedicine.diseaseEchocardiography DopplerThyroxinesymbolsCardiologyFemaleCardiology and Cardiovascular MedicinebusinessDoppler effectThe American Journal of Cardiology
researchProduct

Reliability of the bright liver echo pattern in diagnosing steatosis in patients with cryptogenic and HCV-related hypertransaminasaemia.

2008

Aim To evaluate the reliability of the bright liver (BL) echo pattern on ultrasound to detect histological steatosis in chronic cryptogenic hypertransaminasaemia (CCH) and hepatitis C virus (HCV)-related forms of hypertransaminasaemia. Materials and methods One hundred and fifty patients, 54 with CCH and 96 with HCV hypertransaminasaemia (76 genotype 1/2 and 20 genotype 3), were enrolled. Histological steatosis was measured as the percentage of hepatocytes involved. The reliability of the BL sign was estimated using the sensitivity, specificity, positive and negative predictive values. Results Histological steatosis was present in 102/150 patients (68%) divided into 59/96 (62%) in the HCV g…

AdultMalemedicine.medical_specialtyHepatitis C virusHepacivirusmedicine.disease_causeGastroenterologySensitivity and SpecificityInternal medicineStatistical significanceGenotypemedicinePrevalenceHumansRadiology Nuclear Medicine and imagingProspective StudiesUltrasonography Doppler ColorTransaminasesHepatitis Chronicbiologybusiness.industryFatty liverGeneral MedicineHepatitis CMiddle Agedmedicine.diseasebiology.organism_classificationHepatitis CConfidence intervalFatty LiverItalyLiverHepatocytesFemalebright liver ultrasound steatosis cryptogenic hypertransaminasaemiaSteatosisbusinessBiomarkersClinical radiology
researchProduct

Measurement of Cortical Microcirculation During Intracranial Aneurysm Surgery by Combined Laser-Doppler Flowmetry and Photospectrometry

2011

Accidental vessel occlusion is one major risk of intracranial aneurysm surgery potentially causing cerebral ischemia. The intraoperative assessment of cerebral ischemia remains a technological challenge.As a novel approach, cortical tissue integrity was monitored using simultaneous measurements of regional capillary-venous cerebral blood flow (rvCBF), oxygen saturation (Srvo2), and hemoglobin amount (rvHb) during aneurysm surgery.Fifteen patients scheduled for aneurysm surgery of the anterior and posterior circulation were included. A fiber optic probe was placed on the cortex associated with the distal branch of the aneurysmatic vessel. Blinded measurements by combined laser-Doppler flowme…

AdultMalemedicine.medical_specialtyIschemiaNeurosurgical ProceduresBrain IschemiaMicrocirculationAneurysmMonitoring IntraoperativeCortex (anatomy)Laser-Doppler FlowmetrymedicineHumansCerebral perfusion pressureAgedOxygen saturation (medicine)Cerebral Cortexbusiness.industryMicrocirculationSpectrum AnalysisEndovascular ProceduresIntracranial AneurysmMiddle AgedLaser Doppler velocimetrymedicine.diseasemedicine.anatomical_structureCerebral blood flowCerebrovascular CirculationFeasibility StudiesFemaleSurgeryNeurology (clinical)RadiologybusinessNeurosurgery
researchProduct

Metabolic syndrome in subjects with white-coat hypertension: impact on left ventricular structure and function

2007

Some reports have suggested that white-coat hypertension (WCH) is associated with some features of the metabolic syndrome (MetS). These metabolic disturbances, instead of WCH per se, may potentially explain the greater extent of end-organ damage sometimes observed in WCH subjects (WCHs) when compared to normotensive individuals (NTs). The aim of the present cross-sectional study was to compare left ventricular (LV) structure and function in three groups of subjects: WCHs with MetS, WCHs without MetS and NTs. A total of 145 WCHs, 35% of whom had MetS, were enrolled. As controls, 35 NTs were also studied. In all subjects, routine blood chemistry, echocardiographic examination and 24-h ambulat…

AdultMalemedicine.medical_specialtyLeft ventricular structureAmbulatory blood pressureCross-sectional studyWhite coat hypertensionDoppler echocardiographyVentricular Function LeftMetabolic syndrome white-coat hypertension left ventricular massInternal medicineInternal MedicinemedicineHumansAgedMetabolic Syndromemedicine.diagnostic_testbusiness.industryMiddle Agedmedicine.diseaseEchocardiography DopplerDeceleration timeEndocrinologyCross-Sectional StudiesBlood chemistryHypertensionCardiologyFemaleHypertrophy Left VentricularMetabolic syndromebusiness
researchProduct

Cerebrovascular and cardiovascular variability interactions investigated through conditional joint transfer entropy in subjects prone to postural syn…

2017

Objective: A model-based conditional transfer entropy approach was exploited to quantify the information transfer in cerebrovascular (CBV) and cardiovascular (CV) systems in subjects prone to develop postural syncope. Approach: Spontaneous beat-to-beat variations of mean cerebral blood flow velocity (MCBFV) derived from a transcranial Doppler device, heart period (HP) derived from surface electrocardiogram, mean arterial pressure (MAP) and systolic arterial pressure (SAP) derived from finger plethysmographic arterial pressure device were monitored at rest in supine position (REST) and during 60° head-up tilt (TILT) in 13 individuals (age mean ± standard deviation: 28 ± 9 years, min-max r…

AdultMalemedicine.medical_specialtyMean arterial pressureSupine positioncerebral autoregulationAdolescentPhysiologyUltrasonography Doppler TranscranialEntropyBiomedical EngineeringBiophysics030204 cardiovascular system & hematologyBaroreflexCerebral autoregulationSyncope03 medical and health sciencesElectrocardiographyYoung Adult0302 clinical medicinehead-up tiltHeart RatePhysiology (medical)Internal medicineinformation transfermedicineHeart rate variabilityHumansbaroreflexArterial Pressurebusiness.industryautonomic nervous systemheart rate variabilitySignal Processing Computer-AssistedTranscranial DopplerPlethysmographyBlood pressureBiophysicCerebral blood flowpostural syncopeAnesthesiaCerebrovascular CirculationSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaCardiologyFemaleDisease Susceptibilitybusiness030217 neurology & neurosurgeryHumanPhysiological measurement
researchProduct

Unexpected middle cerebral artery peak systolic velocity values in the normal fetal population. Are they a matter of concern?

2018

AbstractObjective: The aim of this study was to investigate in the fetus the relationship between unexpected high middle cerebral artery peak systolic velocity (middle cerebral artery (MCA) peak sy...

AdultMalemedicine.medical_specialtyMiddle Cerebral ArteryPopulationGestational Age030204 cardiovascular system & hematologyUltrasonography PrenatalUmbilical Arteries03 medical and health sciences0302 clinical medicineFetal anemiaPregnancymedicine.arteryInternal medicinemedicineHumansProspective StudieseducationFetuseducation.field_of_study030219 obstetrics & reproductive medicinebusiness.industryInfant NewbornObstetrics and GynecologyFetal dopplerAnemiaUltrasonography DopplerFetal DiseasesPediatrics Perinatology and Child HealthMiddle cerebral arteryCardiologyFemalebusinessBlood Flow VelocityThe journal of maternal-fetalneonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
researchProduct

Diagnostic accuracy of current sonographic criteria for the detection of outflow abnormalities in the internal jugular veins

2012

Objectives: This study was aimed at evaluation of the diagnostic value of Doppler sonography for the assessment of abnormalities in the internal jugular veins (IJVs). Method: One hundred and sixteen IJVs were assessed in 58 patients with associated multiple sclerosis. Findings of Doppler sonography were compared with results of the reference test: catheter venography. Results: At least one positive extracranial sonographic criterion suggesting venous abnormality was found in 92.2% of the assessed veins. Yet, sensitivity, specificity, positive and negative predictive values of sonography were low: 93.4%, 12.0%, 79.4% and 33.3% for at least one positive criterion, and for at least two positiv…

AdultMalemedicine.medical_specialtyMultiple SclerosisDiagnostic accuracySensitivity and SpecificitymedicineHumansUltrasonography Doppler ColorAgedphlebographybusiness.industryDoppler ultrasonoundGeneral MedicineMiddle Agedmedicine.diseaseDoppler sonographyFemaleOutflowDoppler ultrasoundRadiologyJugular VeinsCardiology and Cardiovascular MedicineVenous malformationbusinessvenous malformationPhlebology : the journal of venous disease
researchProduct