Impact of Gamma Radiation on Dynamic RDSON Characteristics in AlGaN/GaN Power HEMTs
2019
GaN high-electron-mobility transistors (HEMTs) are promising next-generation devices in the power electronics field which can coexist with silicon semiconductors, mainly in some radiation-intensive environments, such as power space converters, where high frequencies and voltages are also needed. Its wide band gap (WBG), large breakdown electric field, and thermal stability improve actual silicon performances. However, at the moment, GaN HEMT technology suffers from some reliability issues, one of the more relevant of which is the dynamic on-state resistance (R) regarding power switching converter applications. In this study, we focused on the drain-to-source on-resistance (R) characteristic…
SU-E-T-691: Shielding Evaluation of a Treatment Room with An Electronic Brachytherapy System
2015
Purpose: Esteya™ (Elekta) is a brachytherapy electronic system used for treating skin cancer lesions. This unit is based on a 69.5 kV X-ray source and a surface applicator which produces a circular beam of a specific diameter, which varies from 1 to 3 cm. This study aims to establish the radiation protection measures for the system. Methods: A characterization of the scattered and leakage radiation of the system was implemented by means of experimental measurements. The scattered radiation measurements were performed with a Berthold LB133 ionization chamber, evaluating the dose rate for different distances from the applicator surface. The patient was simulated through water equivalent solid…
SU-F-T-63: Dosimetric Relevance of the Valencia and Leipzig HDR Applicators Plastic Cap
2016
Purpose: Utilization of HDR brachytherapy treatment of skin lesions using collimated applicators, such as the Valencia or Leipzig is increasing. These applicators are made of cup-shaped tungsten material in order to focalize the radiation into the lesion and to protect nearby tissues. These applicators have an attachable plastic cap that removes secondary electrons generated in the applicator and flattens the treatment surface. The purpose of this study is to examine the dosimetric impact of this cap, and the effect if the cap is not placed during the HDR fraction delivery. Methods: Monte Carlo simulations have been done using the code Geant4 for the Valencia and Leipzig applicators. Dose r…
Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions
2016
Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…
Gamma-ray spectrometric measurement of radionuclide purity of radiopharmaceuticals contained in bottle samples
2012
The radionuclide purity of a radiopharmaceutical product is usually measured by gamma-ray spectrometry with various measurement geometries. The importance of this test is that the radionuclide impurities, if present, result in an increase in the radiation dose to the patient without contributing to diagnostic information and in some cases may also interfere with the marking molecules and affect the proper conduct of diagnostic examination. In this work, gamma-ray spectrometry is used to determine the amounts of impurities by adopting as measurement geometry the same bottle containing eluted or prepared radiopharmaceuticals. In addition to high-purity germanium semiconductor detectors, the u…
Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures
2018
Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of …
Gamma-ray irradiation tests of CMOS sensors used in imaging techniques
2014
Technologically-enhanced electronic image sensors are used in various fields as diagnostic techniques in medicine or space applications. In the latter case the devices can be exposed to intense radiation fluxes over time which may impair the functioning of the same equipment. In this paper we report the results of gamma-ray irradiation tests on CMOS image sensors simulating the space radiation over a long time period. Gamma-ray irradiation tests were car ried out by means of IGS-3 gamma irradiation facility of Palermo Uni ver sity, based on 60Co sources with dif fer ent ac tiv i ties. To re duce the dose rate and re al ize a nar row gamma-ray beam, a lead-collimation sys tem was pur posely …
Statistical methods for determining components non-liniarities, from thermoluminescent devices
2016
Thermoluminescent (TLD) dosimeters enjoy wide usage due to low cost and simplicity of use. They have however large errors at high doses in mixed-radiation fields, where non-linear effects occur. Algorithms based on the Akaike criterion [1] are presented for determining the maximal (physically meaningful) polynomial order with which the non-linearities are modeled. This depends on the number of points existing on a curve and on the points' errors.
Does the immune answer to Bacillus thuringiensis infection is the same in larvae, females and males of Rhynchophorus ferrugineus?
2021
Bacillus thuringiensis (Bt) è considerato un potenziale batterio entomopatogeno per la lotta al Rhynchophorus ferrugineus, coleottero da quarantena infestante le palme. In questo lavoro si considerano gli effetti dell’infezione di Bt in larve, maschi e femmine del punteruolo rosso. La patogenicità è stata valutata stimando la LD50 (Lethal Median Dose) e la LT50 (Lethal Median Time), il numero totale di emociti ed il tipo di emociti (Differential Haemocytes counts) ed inoltre l’espressione delle proteine Heat Shock Protein 70 (HSP70) negli emociti e nel cerebro. La mortalità di entrambi i sessi e delle larve aumentava all’aumentare della dose e del tempo di esposizione. Tuttavia le larve han…
Analysis of radionuclide concentration in air released through the stack of a radiopharmaceutical production facility
2014
The quantities of positron emitting radionuclides used in medical diagnostics and the number of radiopharmaceutical production facilities have been estimated to be growing worldwide. In this field, an amount of these radionuclides might become airborne and escape into the environment during the process of production and/or during administration by hospital personnel. Therefore, the analysis of dose to the operating staff as well as to the public, due to releases through the stack, is a very important issue. To this end, sampling and measurement of radionuclide concentration in air released through the stack of a Nuclear Medicine Center (NMC), provided with a cyclotron for radiopharmaceutica…