Impact of Gamma Radiation on Dynamic RDSON Characteristics in AlGaN/GaN Power HEMTs

2019

GaN high-electron-mobility transistors (HEMTs) are promising next-generation devices in the power electronics field which can coexist with silicon semiconductors, mainly in some radiation-intensive environments, such as power space converters, where high frequencies and voltages are also needed. Its wide band gap (WBG), large breakdown electric field, and thermal stability improve actual silicon performances. However, at the moment, GaN HEMT technology suffers from some reliability issues, one of the more relevant of which is the dynamic on-state resistance (R) regarding power switching converter applications. In this study, we focused on the drain-to-source on-resistance (R) characteristic…

Materials scienceassurance testingRadiation effects02 engineering and technologyHigh-electron-mobility transistorradiation hardness01 natural scienceslcsh:Technologylaw.inventiontotal ionizing dose (TID)lawPower electronics0103 physical sciencesGeneral Materials Sciencelcsh:MicroscopyHigh-electron-mobility transistor (HEMT)Radiation hardeningLeakage (electronics)lcsh:QC120-168.85010302 applied physicsRadiation hardnessAssurance testinghigh-electron-mobility transistor (HEMT)lcsh:QH201-278.5business.industrylcsh:TTransistorWide-bandgap semiconductor021001 nanoscience & nanotechnologyThreshold voltageSemiconductorlcsh:TA1-2040Gallium nitride (GaN)adiation effectsradiation effectsOptoelectronicslcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringTotal ionizing dosegallium nitride (GaN)0210 nano-technologybusinesslcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971Materials
researchProduct

SU-E-T-691: Shielding Evaluation of a Treatment Room with An Electronic Brachytherapy System

2015

Purpose: Esteya™ (Elekta) is a brachytherapy electronic system used for treating skin cancer lesions. This unit is based on a 69.5 kV X-ray source and a surface applicator which produces a circular beam of a specific diameter, which varies from 1 to 3 cm. This study aims to establish the radiation protection measures for the system. Methods: A characterization of the scattered and leakage radiation of the system was implemented by means of experimental measurements. The scattered radiation measurements were performed with a Berthold LB133 ionization chamber, evaluating the dose rate for different distances from the applicator surface. The patient was simulated through water equivalent solid…

Materials sciencebusiness.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineIonizing radiationLead shieldingAbsorbed doseIonization chamberElectromagnetic shieldingmedicineDosimetryRadiation protectionbusinessNuclear medicineMedical Physics
researchProduct

SU-F-T-63: Dosimetric Relevance of the Valencia and Leipzig HDR Applicators Plastic Cap

2016

Purpose: Utilization of HDR brachytherapy treatment of skin lesions using collimated applicators, such as the Valencia or Leipzig is increasing. These applicators are made of cup-shaped tungsten material in order to focalize the radiation into the lesion and to protect nearby tissues. These applicators have an attachable plastic cap that removes secondary electrons generated in the applicator and flattens the treatment surface. The purpose of this study is to examine the dosimetric impact of this cap, and the effect if the cap is not placed during the HDR fraction delivery. Methods: Monte Carlo simulations have been done using the code Geant4 for the Valencia and Leipzig applicators. Dose r…

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineCollimated lightAbsorbed dosemedicineDosimetryRadiochromic filmNuclear medicinebusinessDose rateSkin lesionMedical Physics
researchProduct

Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions

2016

Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomHigh-Dose Rate Brachytherapy030218 nuclear medicine & medical imagingPercentage depth dose curve03 medical and health sciencesKerma0302 clinical medicine030220 oncology & carcinogenesisIonization chambermedicineDosimetryNuclear medicinebusinessMedical Physics
researchProduct

Gamma-ray spectrometric measurement of radionuclide purity of radiopharmaceuticals contained in bottle samples

2012

The radionuclide purity of a radiopharmaceutical product is usually measured by gamma-ray spectrometry with various measurement geometries. The importance of this test is that the radionuclide impurities, if present, result in an increase in the radiation dose to the patient without contributing to diagnostic information and in some cases may also interfere with the marking molecules and affect the proper conduct of diagnostic examination. In this work, gamma-ray spectrometry is used to determine the amounts of impurities by adopting as measurement geometry the same bottle containing eluted or prepared radiopharmaceuticals. In addition to high-purity germanium semiconductor detectors, the u…

Materials sciencebusiness.product_categorySettore ING-IND/20 - Misure E Strumentazione Nucleariradionuclide purityScintillatorMass spectrometrymedicineBottlelcsh:Nuclear and particle physics. Atomic energy. RadioactivitySafety Risk Reliability and Qualitygamma-ray spetrometryRadionuclidemedicine.diagnostic_testbusiness.industryElutionRadiochemistrydoseGamma raySemiconductor detectorPETNuclear Energy and EngineeringPositron emission tomographySPECTradionuclide purity PET SPECT gamma-ray spetrometry doselcsh:QC770-798businessNuclear medicine
researchProduct

Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures

2018

Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of …

Materials scienceeye lens doseTLDImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsProtective Clothingfashionbackscatter correction factorCalibrationmedicineDosimetryFluoroscopylead apronWaste Management and DisposalDosimetermedicine.diagnostic_testRadiation Dosimetersbusiness.industryEquivalent dosePublic Health Environmental and Occupational HealthEquipment DesignGeneral MedicinefluoroscopyLeadFluoroscopy030220 oncology & carcinogenesisfashion.garmentCalibrationLead apronThermoluminescent DosimetryThermoluminescent dosimeterbusinessJournal of Radiological Protection
researchProduct

Gamma-ray irradiation tests of CMOS sensors used in imaging techniques

2014

Technologically-enhanced electronic image sensors are used in various fields as diagnostic techniques in medicine or space applications. In the latter case the devices can be exposed to intense radiation fluxes over time which may impair the functioning of the same equipment. In this paper we report the results of gamma-ray irradiation tests on CMOS image sensors simulating the space radiation over a long time period. Gamma-ray irradiation tests were car ried out by means of IGS-3 gamma irradiation facility of Palermo Uni ver sity, based on 60Co sources with dif fer ent ac tiv i ties. To re duce the dose rate and re al ize a nar row gamma-ray beam, a lead-collimation sys tem was pur posely …

Materials scienceimaging technique CMOS image sensor gamma irradiationPixelSettore ING-IND/20 - Misure E Strumentazione Nuclearibusiness.industryImage qualityRadiationimaging techniqueSettore ING-INF/01 - Elettronicagamma irradiationBackground noiseNuclear Energy and EngineeringCMOSCMOS image sensorAbsorbed doseOptoelectronicslcsh:QC770-798lcsh:Nuclear and particle physics. Atomic energy. RadioactivityIrradiationImage sensorSafety Risk Reliability and QualitybusinessNuclear Technology and Radiation Protection
researchProduct

Statistical methods for determining components non-liniarities, from thermoluminescent devices

2016

Thermoluminescent (TLD) dosimeters enjoy wide usage due to low cost and simplicity of use. They have however large errors at high doses in mixed-radiation fields, where non-linear effects occur. Algorithms based on the Akaike criterion [1] are presented for determining the maximal (physically meaningful) polynomial order with which the non-linearities are modeled. This depends on the number of points existing on a curve and on the points' errors.

Mathematical optimizationmedia_common.quotation_subjectPhysics::Medical PhysicsPolynomial order02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesThermoluminescence0103 physical sciencesAkaike criterionHigh dosesThermoluminescent dosimeterSimplicity010306 general physics0210 nano-technologyAlgorithmmedia_commonMathematics2016 IEEE 22nd International Symposium for Design and Technology in Electronic Packaging (SIITME)
researchProduct

Does the immune answer to Bacillus thuringiensis infection is the same in larvae, females and males of Rhynchophorus ferrugineus?

2021

Bacillus thuringiensis (Bt) è considerato un potenziale batterio entomopatogeno per la lotta al Rhynchophorus ferrugineus, coleottero da quarantena infestante le palme. In questo lavoro si considerano gli effetti dell’infezione di Bt in larve, maschi e femmine del punteruolo rosso. La patogenicità è stata valutata stimando la LD50 (Lethal Median Dose) e la LT50 (Lethal Median Time), il numero totale di emociti ed il tipo di emociti (Differential Haemocytes counts) ed inoltre l’espressione delle proteine Heat Shock Protein 70 (HSP70) negli emociti e nel cerebro. La mortalità di entrambi i sessi e delle larve aumentava all’aumentare della dose e del tempo di esposizione. Tuttavia le larve han…

Median lethal dose median lethal time stress answer haemocytes brain HSP70.Settore AGR/11 - Entomologia Generale E ApplicataSettore BIO/05 - Zoologiadose letale mediana tempo letale mediano risposta allo stress emociti cerebro HSP70
researchProduct

Analysis of radionuclide concentration in air released through the stack of a radiopharmaceutical production facility

2014

The quantities of positron emitting radionuclides used in medical diagnostics and the number of radiopharmaceutical production facilities have been estimated to be growing worldwide. In this field, an amount of these radionuclides might become airborne and escape into the environment during the process of production and/or during administration by hospital personnel. Therefore, the analysis of dose to the operating staff as well as to the public, due to releases through the stack, is a very important issue. To this end, sampling and measurement of radionuclide concentration in air released through the stack of a Nuclear Medicine Center (NMC), provided with a cyclotron for radiopharmaceutica…

Medical cyclotron radioactive air effluent PET Potential dose.Settore ING-IND/20 - Misure E Strumentazione Nucleari