Search results for " EPR"
showing 10 items of 85 documents
EPR ANALYSIS OF ALANINE WITH GADOLINIUM FOR DOSIMETRY AT TRIGA MARK II REACTOR OF MAINZ
2015
Negli ultimi anni il crescente interesse verso la radioterapia a cattura neutronica (internazionalmente nota come Neutron Capture Therapy - NCT) per il trattamento di neoplasie ha stimolato diverse attività di ricerca finalizzate alla caratterizzazione del fascio utilizzato e all'ottimizzazione delle procedure radioterapiche. La corretta riuscita del trattamento NCT e il monitoraggio della dose impartita non possono prescindere dalla valutazione delle varie componenti del fascio impiegato (neutronica e fotonica). Infatti, durante le procedure di moderazione dei neutroni, si verifica la produzione di fotoni e la stima dei rischi a cui sono soggetti i tessuti sani sottoposti al campo misto ne…
Role of the support on the activity of H3PW12O40 supported on SiO2 or TiO2 in Catalytic and Photocatalytic propene hydration: An EPR Study
2016
Catalytic and catalytic photo-assisted hydration of propene to 2-propanol in gas-solid regime at atmospheric pressure and 85°C were carried out by using the Keggin heteropolyacid (HPA) H3PW12O40 (PW12) supported on home prepared SiO2, WO3, TiO2 or N-doped TiO2. The HPA played the key role both in catalytic and photocatalytic reactions; however, the support strongly influenced the binary material performance. The contemporary presence of heat and UV light improved the activity of the (photo)catalysts. EPR (Electron Paramagnetic Resonance) has been used to understand the intimate mechanism underlying the photoactivity of the supported heteropolyacid and the role played by the support.
ALANINE/EPR DOSIMETRY APPLIED TO THE VALIDATION OF A TOTAL BODY IRRADIATION (TBI) PROTOCOL AND TREATMENT PLANNING DOSE CALCULATION USING A HUMANOID P…
2015
L’irraggiamento a corpo intero (Total Body Irradiation - TBI) è una tecnica di radioterapia oncologica di largo impiego nella clinica ematoncologica nell’ambito del trattamento di pazienti avviati al trapianto di midollo osseo o al trapianto di cellule staminali periferiche. La TBI da una parte permette di sopprimere il sistema immunitario del ricevente per prevenire il rigetto del midollo del donatore ed eliminare le cellule neoplastiche residue dai trattamenti chemioterapici. In genere, la modalità di somministrazione della TBI prevede irraggiamenti in 3 giorni consecutivi con un bi-frazionamento giornaliero (2 Gy, 2 volte al giorno con intervallo minimo di 6 ore tra le sedute, per 3 gior…
EPR DOSIMETRY WITH ALANINE FOR TOTAL BODY IRRADIATION USING AN ANTHROPOMORPHIC PHANTOM
2016
The Total Body Irradiation (TBI) is a radiation therapy technique widely used in clinical hemato-oncological treatment of patients that underwent bone marrow transplantation or peripheral stem cell transplantation. Typically, the administration of TBI treatment provides irradiations in 3 consecu-tive days with a double daily fractionation, although other dose fractionation modes have been widely adopted in the clinic procedures. Although this tech-nique allows to irradiate the whole body from head to toes, it has some limitations such as the lack of homogeneity of the dose distribution (which can show varia-tions of 20% in the different areas), irradiation of critical organs such as lungs, …
Influence of crystallinity and OH surface density on the photocatalytic activity of TiO2 powders
2014
Abstract The aim of the work was to study the influence of crystallinity and OH surface density on the photocatalytic activity of two commercial and two home-prepared TiO 2 powders. The samples were characterized by X-ray diffraction (XRD), thermogravimetric analysis (TG) and electron paramagnetic resonance (EPR) measurements. The photoactivity of the powders was tested employing the photodegradation of 4-nitrophenol (4-NP) and the selective oxidation of 4-methoxybenzyl alcohol (4-MBA) to 4-methoxybenzaldehyde ( p -anisaldehyde) under UV irradiation. An anti-correlation between oxidant power and selectivity of the various samples was found. A higher rate of 4-NP degradation was exhibited by…
EPR/alanine dosimetry for verification in Helical Tomotherapy Stereotactic Radiosurgery (HTSRS) treatments
2018
Introduction Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. In this study the accuracy of the dose delivered in SRS by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test using alanine pellets and gafchromic films. Methods Dose verifications were made using alanine dosimeters placed in an antropomorphic head phantom (Alderson Rando Phantom) under different treatment conditions in case of both single and multiple brain tumors. 1.25mm slice kVCT scan of the phantom was used to generate SRS plans on the TomoTherapy Plann…
Characterization of alanine EPR detectors response in clinical carbon ion beams
2012
Heavy-ions beams offer several advantages compared to other radiation such as low lateral scattering and high biological effectiveness (RBE) in the Bragg peak region, making them particularly attractive for the treatment of radio-resistant tumors localized close to organs at risk [1]. Although ion beam radiotherapy ultimately requires dose prescription in terms of biological dose or cell survival, absorbed dose is still the quantity mostly used in clinical quality assurance and to dosimetrically characterize the beam. Moreover, the nuclear projectile fragmentation of heavy ions because of inelastic nuclear interactions with medium produces secondary particles with lower Z. The detailed know…
Determinazione della componente gamma nella colone termica del reattore TRIGA di Pavia tramite Dosimetri ESR di alanina
2016
Negli ultimi anni il crescente interesse verso la radioterapia a cattura neutronica (internazionalmente nota come Neutron Capture Therapy - NCT) per il trattamento di neoplasie ha stimolato diverse attività di ricerca finalizzate alla caratterizzazione del fascio utilizzato e all'ottimizzazione delle procedure radioterapiche. Tra i vari sistemi dosimetrici trovano largo impiego i rivelatori a stato solido ESR (Risonanza di Spin Elettronico) a base di alanina che presentano diversi vantaggi come la tessuto equivalenza, la linearità della risposta in un ampio intervallo di dose, l'elevata stabilità dei radicali liberi radioindotti, la non distruttività della lettura del dosimetro e il basso c…
Near Isotropic D4d Spin Qubits as Nodes of a Gd(III)-Based Metal-Organic Framework
2021
Embedding coherent spin motifs in reproducible molecular building blocks is a promising pathway for the realization of quantum technologies. Three-dimensional (3D) MOFs are a versatile platform for the rational design of extended structures employing coordination chemistry. Here, we report the synthesis and characterization of a gadolinium(III)-based MOF, [Gd(bipyNO)4](TfO)3·xMeOH (bipyNO = bipyridine,N,N′-dioxide; TfO = triflate; and MeOH = methanol) (quMOF-1), which presents a unique coordination geometry that leads to a tiny magnetic anisotropy (in terms of D, an equivalent zero-field splitting would be achieved by D = 0.006 cm–1) even compared with regular Gd(III) complexes. Pulsed elec…