Search results for " Electrical and Electronic Engineering"
showing 10 items of 118 documents
Smart energy users: ICT instruments for the consumer awareness
2015
The European Commission is supporting many projects in the field of energy saving, with the aim to improve user behavior and to help Europe to meet emission targets. In October 2012, the European Union adopted the Energy Efficiency Directive with the aim to reduce the primary energy consumption by 20% by 2020. One key point in the reduction of energy consumption energy is the awareness of final users about their usage of energy. At the same time, policies aimed at improving the efficiency of energy use, are a keystone in the strategies of leading Distribution System Operators (DSOs) and energy retail companies that started to offer, in addition to the energy supply, services and suggestions…
The TES-based cryogenic anticoincidence detector for IXO: First results from large area prototypes
2010
The technique which combines high resolution spectroscopy with imaging capability is a powerful tool to extract fundamental information in X-ray Astrophysics and Cosmology. TES (Transition Edge Sensors)-based microcalorimeters match at best the requirements for doing fine spectroscopy and imaging of both bright (high count rate) and faint (poor signal-to-noise ratio) sources. For this reason they are considered among the most promising detectors for the next high energy space missions and are being developed for use on the focal plane of the IXO (International X-ray Observatory) mission. In order to achieve the required signal-to-noise ratio for faint or diffuse sources it is necessary to r…
Baseline design of the thermal blocking filters for the X-IFU detector on board ATHENA
2014
ATHENA is an advanced X-ray observatory designed by a large European consortium to address the science theme "Hot and Energetic Universe" recently selected by ESA for L2 – the second Large-class mission within the Cosmic Vision science program (launch scheduled in 2028). One of the key instruments of the mission is the X-ray Integral Field Unit (X-IFU), an array of Transition Edge Sensor (TES) micro-calorimeters with high energy resolution (2.5 eV @ 6 keV) in the energy range 0.2÷12 keV, operating at the focal plane of a large effective area high angular resolution (5" HEW) grazing incidence X-ray telescope. The X-IFU operates at temperatures below 100 mK and thus requires a sophisticated c…
The focal plane assembly for the Athena X-ray Integral Field Unit instrument
2016
This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a ~ 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off…
Anomalous transport effects on switching currents of graphene-based Josephson junctions
2017
We explore the effect of noise on the ballistic graphene-based small Josephson junctions in the framework of the resistively and capacitively shunted model. We use the non-sinusoidal current-phase relation specific for graphene layers partially covered by superconducting electrodes. The noise induced escapes from the metastable states, when the external bias current is ramped, give the switching current distribution, i.e. the probability distribution of the passages to finite voltage from the superconducting state as a function of the bias current, that is the information more promptly available in the experiments. We consider a noise source that is a mixture of two different types of proce…
Results of a literature review on methods for estimating buildings energy demand at district level
2019
Abstract In the framework of distributed energy planning, evaluating reliable energy profiles of different sectors has a prominent role. At the same time, it is a quite challenging task, since the availability of actual energy profiles of buildings at the district level is not widespread. A survey of over 70 studies in scientific literature has been accomplished and a set of criteria has been defined for classifying the selected contributions based on the energy demand data features, source and/or estimation methods, highlighting the ones adopting hourly energy profiles. As final results, tables summarizing the main methods characteristics and a selection of studies providing directly useab…
Soil Water Content Assessment: Critical Issues Concerning the Operational Application of the Triangle Method
2015
Knowledge of soil water content plays a key role in water management efforts to improve irrigation efficiency. Among the indirect estimation methods of soil water content via Earth Observation data is the triangle method, used to analyze optical and thermal features because these are primarily controlled by water content within the near-surface evaporation layer and root zone in bare and vegetated soils. Although the soil-vegetation-atmosphere transfer theory describes the ongoing processes, theoretical models reveal limits for operational use. When applying simplified empirical formulations, meteorological forcing could be replaced with alternative variables when the above-canopy temperatu…
Innovative control logics for a rational utilization of electric loads and air-conditioning systems in a residential building
2015
The paper focuses on the evaluation of the impact on residential buildings of innovative control logics defined for a rational utilization of the electric loads and air-conditioning systems. The control logics are implementable thanks to a Decision Support and Energy Management Systems developed by the same authors and easily installable in new and still-existing houses. The paper shows how a significant reduction of the primary energy consumption can be obtained by controlling the air-conditioning units together with the other electric loads of the house. After having explained how the control logics operate, a simulation tool is described, developed for a preliminary evaluation of their e…
New approach for harmonic mitigation in single-phase five-level CHBMI with fundamental frequency switching
2017
The main objective of this paper is to study and analyse the voltage output waveform of a multilevel inverter, to suggest a new approach for harmonic mitigation improving the converter performance. These last type of converters represent a new technology in the field of DC/AC electrical energy conversion, presenting advantages respect to the traditional converters. In fact, the multilevel power converters present a low harmonic content and a high voltage level. The paper considers a five-level single-phase cascaded H-bridge inverter and fundamental frequency modulation techniques. The voltage waveform analysis has allowed to identify a working area of the converter where there are lowest va…
Broken rotor bars detection via Park's vector approach based on ANFIS
2014
Many attempts have been made on fault diagnosis of induction motors based on frequency and time domain analysis of stator current. In this paper, first the Park's vector transformation and frequency analysis for fault detection of induction motors are introduced. Then a smart approach using Adaptive Neuro Fuzzy Inference System (ANFIS) is proposed. This approach uses the time domain features derived from the Park's vector transformation of stator current. By the proposed method, a partial break including 5 mm crack on a bar, one broken bar and two broken bars using experimental data are investigated. It will be shown that features derived from Park's vector compared to features obtained fro…