Search results for " Electronics"
showing 10 items of 580 documents
Mixed-type circuits with distributed and lumped parameters as correct models for integrated structures
1991
The technology of integrated circuits imposes upon their designers the need to deal with structures with distributed parameters. Figure 4.1 shows a schematic diagram of part of a digital integrated chip, consisting of an n MOS transistor with gate (G), drain (D) and source (S) as terminals, and its thin-film connection with the rest of the chip. This on-chip connection can be made by metals (Al, W), polycristaline silicon (polysilicon) or metal suicides (WSi 2 ). Alternative materials to oxide-passivated silicon substrates are saphire and gallium arsenide (Saraswat and Mohammadi [1982], Yuan et al. [1982], Passlack et al. [1990]).
Performance of the Fully Digital FPGA-Based Front-End Electronics for the GALILEO Array
2014
In this work we present the architecture and results of a fully digital Front End Electronics (FEE) read out system developed for the GALILEO array. The FEE system, developed in collaboration with the Advanced Gamma Tracking Array (AGATA) collaboration, is composed of three main blocks: preamplifiers, digitizers and preprocessing electronics. The slow control system contains a custom Linux driver, a dynamic library and a server implementing network services. The digital processing of the data from the GALILEO germanium detectors has demonstrated the capability to achieve an energy resolution of 1.53 per mil at an energy of 1.33 MeV.
The ATLAS Level-1 Calorimeter Trigger
2008
The ATLAS Level-1 Calorimeter Trigger uses reduced-granularity information from all the ATLAS calorimeters to search for high transverse-energy electrons, photons, tau leptons and jets, as well as high missing and total transverse energy. The calorimeter trigger electronics has a fixed latency of about 1 microsecond, using programmable custom-built digital electronics. This paper describes the Calorimeter Trigger hardware, as installed in the ATLAS electronics cavern.
Well-posed nonlinear problems in integrated circuits modeling
1991
In this paper we study the problem (E) + (BC) + (IC) (see below) which represents a model for integrated circuits. We assume that the distributed parametersr(x) andc(x) are nonconstant, dielectric leakages depend on thex-coordinate as well as the voltage level, while the interconnecting multiport is nonlinear and possibly multivalued.
Digital filtering and analysis for a semiconductor X-ray detector data acquisition
2007
Abstract Pile-up distortion is a major drawback in X-ray spectroscopy at high count rate. Pulse width narrowing with shaping techniques can lead to the reduction of the pile-up distortion, but a low shaping time reduces the noise filtration and leads to a poor energy resolution. Thus, only a best compromise solution between the pile-up and the noise requirements is achievable. The hardware manipulation needed to adjust the parameters of the traditional electronic shaping amplifiers makes it uneasy to tests various settings in different conditions. Digital techniques can help to overcome such difficulties. A digital signal processing and analysis system for X-ray spectroscopy is described in…
A Coupled Fixed Point Theorem in Fuzzy Metric Space Satisfying ϕ-Contractive Condition
2013
The intent of this paper is to prove a coupled fixed point theorem for two pairs of compatible and subsequentially continuous (alternately subcompatible and reciprocally continuous) mappings, satisfyingϕ-contractive conditions in a fuzzy metric space. We also furnish some illustrative examples to support our results.
An In Vitro Stereomicroscopic Evaluation of Bioactivity between Neo MTA Plus, Pro Root MTA, BIODENTINE & Glass Ionomer Cement Using Dye Penetrati…
2021
The ideal root end filling material should form a tight seal in the root canal by adhering to the cavity walls. Several materials have been used for root end filling. The present study aims to find out and compare the bioactivity of Neo MTA Plus, Pro Root MTA White, BIODENTINE & glass ionomer cement as root end filling materials using 1% methylene blue as tracer. Materials and methods: 80 extracted human permanent maxillary anterior teeth were used in the study. They were divided into four groups. Specimens were sectioned transversely in the cervical area to separate the crown from the root. The root canal was obturated with gutta percha and zinc oxide eugenol sealers. Thereafter, each …
High resolution 80Se(n,γ) cross section measurement at CERN n_TOF and development of the novel i-TED detection system
2022
El proceso (-s) de captura lenta de neutrones es responsable de la formación de la mitad de los elementos más pesados que el hierro en el universo. A pesar de la larga escala de tiempo de este proceso, la larga vida media de algunos isótopos inestables a lo largo del flujo de reacción del proceso-s crea puntos de ramificación que conducen a una división de la ruta de la nucleosíntesis. 79Se (t1/2 = 3.27 x 10^5 y) representa uno de los núcleos ramificados-s más relevantes y debatidos por dos razones principales. Por un lado, la existencia de estados excitados de baja energía en el 79Se, cuya población puede variar con la temperatura del medio estelar, hace que el patrón de abundancia local…
The influence of building interactions on seismic and elastic body waves
2019
We outline some recent research advances on the control of elastic waves in thin and thick plates, that have occurred since the large scale experiment [S. Brûlé, Phys. Rev. Lett. 112, 133901 (2014)] that demonstrated significant interaction of surface seismic waves with holes structuring sedimentary soils at the meter scale. We further investigate the seismic wave trajectories of compressional body waves in soils structured with buildings. A significant substitution of soils by inclusions, acting as foundations, raises the question of the effective dynamic properties of these structured soils. Buildings, in the case of perfect elastic conditions for both soil and buildings, are shown to int…
A device for spike train sampling with built-in memory.
1987
Abstract The described interface to a digital computer measures interspike interval durations with a resolution of 10 μs. A built-in first-in first-out (FIFO) memory relieves the host computer from frequent I/O intensive tasks. The internal FIFO buffer can store up to 512 data words (wordlength is 16 bit) and works on the dual-port principle. This way the acquisition of a neuronal spike train is completely independent of the computer's simultaneously ongoing data access. A simple handshake protocol between the interface and the computer prevents any overhead communication. The buffer architecture of the instrument releases the host computer from high speed I/O handling schemes like real-tim…