Search results for " Emission-Computed"
showing 5 items of 65 documents
Hepatic mesenchymal hamartoma in a preterm newborn: demonstration by low-dose multidetector CT.
2007
Primary liver tumours are very rare in the neonatal period. Differential diagnoses include haemangioendothelioma, malignant hepatoblastoma and mesenchymal hamartoma. Due to non-specific clinical symptoms and indecisive imaging findings, correct diagnosis may be difficult to establish. We report a female preterm newborn who was delivered at 33 weeks of gestation and in whom ultrasonography (US) revealed a large cystic intraabdominal tumour of unknown origin. For further evaluation, contrast-enhanced multidetector computed tomography (CT) was performed on the 4th day of life using a low-dose protocol (80 kVp, 50 mAs, collimation 0.75 mm, total effective dose 3.6 mSv). Based on CT findings, di…
Mechanism of New Antipsychotic Medications
2003
Antagonism of D 2 -like dopamine receptors is the putative mechanism underlying the antipsychotic efficacy of psychotropic drugs. Positron emission tomographic studies suggest that the antipsychotic effect of dopamine receptor antagonists occurs within a therapeutic window between 60% and 80%(striatal) D 2 receptor occupancy. The incidence of extrapyramidal side effects increases above the 80% threshold. However, the novel atypical antipsychotic drug, aripiprazole, occupies up to 95% of striatal D 2 -like dopamine receptors at clinical doses, and the incidence of extrapyramidal side effects with aripiprazole is no higher than with placebo. The most likely explanation for this finding is ari…
D2-receptor imaging with [123I]IBZM and Single Photon Emission Tomography in psychiatry: a survey of current status
1995
D2-dopamine receptors can be visualized in the human brain in vivo by Single Photon Emission Tomography (SPECT) and the radiolabeled benzamide [123I]IBZM. The present paper reviews the current status of this type of functional brain imaging with respect to basic methodological aspects, data analysis and quantification. The results from published clinical studies in different psychiatric patient populations and normal controls with [123I]IBZM are reviewed. [123I]IBZM-SPECT is a powerful tool for the investigation of D2-dopamine receptor status in psychiatric disorders, different types of drug treatment as well as therapeutic and side effects of pharmacologic agents. However, there still is a…
Sonography and computed tomography in the diagnosis of orbitocranial malformations and tumors
1987
Standardized sonography and CT scanning have distinct advantages and disadvantages in the evaluation of patients with orbital diseases. Echography provides an efficient screening examination in patients presenting with signs and symptoms of orbital pathology. It allows the detection, localization, measurement and in almost 80% differentiation of orbital lesions. High resolution CT scanning gives an excellent topographic display of masses in the orbit. In visualization of intracranial causes of orbital processes and demonstration of changes in the posterior third of the orbit, in the orbital bones and the periorbital sinuses it is superior to ultrasonography.
Estimation of structural and geometrical properties of cortical bone by computerized tomography in 78-year-old women
2009
The structural and geometrical properties of the tibia shaft were investigated at two sections by means of computerized tomography (CT) in 78-year-old women with high (n = 19) and low (n = 17) calcaneal bone mineral density (BMD, g/cm3) previously measured by 125I-photon absorption. The high BMD group had a 20-21% higher tibial BMD and 9-12% higher bone cross-sectional area than was observed in the low BMD group. The distribution of bone mass indicated that the low BMD group had lost bone mainly from the endosteal surface, especially in the anterior part of the tibia. However, both groups had a similar basic pattern of mass distribution at the measured sections. The high BMD group had highe…