Search results for " Emission"
showing 10 items of 1496 documents
Pulsating B and Be stars in the Small Magellanic Cloud
2008
Context: Stellar pulsations in main-sequence B-type stars are driven by the kappa-mechanism due to the Fe-group opacity bump. The current models do not predict the presence of instability strips in the B spectral domain at very low metallicities. As the metallicity of the SMC is lower than Z=0.005, it constitutes a very suitable object to test these predictions. Aims: The main objective is to investigate the existence of B-type pulsators at low metallicities, searching for short-term periodic variability in absorption-line B and Be stars in the SMC. The analysis has been performed in a sample of 313 B and Be stars with fundamental astrophysical parameters accurately determined from high-res…
Aircraft measurements of aerosol particles and trace gases over the Southern Baltic Sea during the BALTIC'15 campaign in 2015
2019
During the BALTIC'15 campaign, conducted in August 2015 over the Southern Baltic Sea, trace gasses (CO2/O3/NOy/SO2) and aerosol particles (number concentration of total/non-volatile/Aitken mode/ Accumulation mode/Coarse mode/refractory black carbon, aerosol extinction coefficient, mass concentration of refractory black carbon were measured). Observations were performed on board of the Alfred Wegener Institute research aircraft Polar 5 during 4 flights: - Scientific flight 1 (SF1) 26 August 2015 - Scientific flight 2 (SF2) 28 August 2015 - Scientific flight 3 (SF3) 28 August 2015 - Scientific flight 4 (SF4) 30 August 2015
Transition-edge sensors for particle-induced X-ray emission spectrometry
2018
A transition-edge sensor array has been applied to particle-induced X-ray emission. We have characterized the detector for quantitative analysis and obtained minimum detection limit over two orders of magnitude better compared to a silicon drift detector. We have also studied chemical effects in analysis of Ti, TiO2 and TiN using proton and heavy ion beams. A chemical shift for TiO2 was observed in proton measurements, and relative multiple ionization X-ray satellite line intensities changed between metallic Ti and other compounds with heavy ions. Detection of low energy X-rays down to 0.5 keV was achieved by installing a polycapillary lens in front of the transition-edge sensor array in ex…
Rumore stradale: ruolo ed efficacia delle pavimentazioni fonoassorbenti nella riduzione delle emissioni sonore
2008
Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
2020
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.
Energy efficiency and photovoltaic solar for greenhouse agriculture
2011
Comparison of 99mTc-Labeled Colloid SPECT/CT and Planar Lymphoscintigraphy in Sentinel Lymph Node Detection in Patients with Melanoma: A Meta-Analysis
2020
We compared the detection rate (DR) for sentinel lymph nodes (SLNS), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus. The literature search was updated until December 31st, 2019. DR was calculated on a per-patient-based analysis; the studies were pooled by their odds ratios (ORs) with a random effects model to assess the significance of difference (p < 0.05). The number of additional S…
Dynamic regimes of cyclotron instability in the afterglow mode of minimum-B electron cyclotron resonance ion source plasma
2016
The paper is concerned with the dynamic regimes of cyclotron instabilities in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source operated in pulsed mode. The instability appears in decaying ion source plasma shortly (1–10 ms) after switching off the microwave radiation of the klystron, and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high-energy electrons along the magnetic field lines. Recently it was shown that this plasma instability causes perturbations of the extracted ion current, which limits the performance of the ion source and generates strong bursts of bremsstrahlung emission. In this artic…
Characteristic Kα emission of electron cyclotron resonance ion source plasmas
2018
This thesis presents the results of an investigation of the volumetric Kα emission rate/inner shell ionization rate from an Electron Cyclotron Resonance Ion Source (ECRIS) plasma tuned predominantly for high charge state ion production. The experimental work include four complimentary studies covering the influence of a parametric sweep of the four source tune parameters i.e microwave power, neutral gas flow, biased disc voltage and magnetic field on the volumetric Kα emission rate, an investigation into the gas mixing effect, an investigation into the effectiveness of double-frequency heating mode and finally an investigation into microwave induced electron losses (relative and direct) from th…
VUV emission spectroscopy combined with H- density measurements in the ion source Prometheus I
2016
“Prometheus I” is a volume H− negative ion source, driven by a network of dipolar electron cyclotron resonance (ECR; 2.45 GHz) modules. The vacuum-ultraviolet (VUV) emission spectrum of low-temperature hydrogen plasmas may be related to molecular and atomic processes involved directly or indirectly in the production of negative ions. In this work, VUV spectroscopy has been performed in the above source, Prometheus I, both in the ECR zones and the bulk (far from ECR zones and surfaces) plasma. The acquired VUV spectra are correlated with the negative ion densities, as measured by means of laser photodetachment, and the possible mechanisms of negative ion production are considered. The well-e…