Search results for " Excimer"

showing 10 items of 30 documents

Excimer laser photorefractive keratectomy for high myopia

1995

Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresCorneal Stromamedicine.medical_treatmentEye diseaseVisual AcuityRefraction OcularExcimerPhotorefractive KeratectomyEpitheliumCorneaVision disorderCorneal OpacityOphthalmologyMyopiamedicineHumansIntraocular PressureDioptreExcimer laserbusiness.industryMiddle AgedPrognosismedicine.diseaseAblationeye diseasesSensory SystemsPhotorefractive keratectomyOphthalmologyFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes

2011

Purpose To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. Setting Private refractive surgery center, Valencia, Spain. Design Cohort study. Methods After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pup…

AdultMalemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuitygenetic structuresCorneal Stromamedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical Flapslaw.inventionCohort StudiesYoung AdultlawRefractive surgeryOphthalmologyMyopiamedicineHumansDioptreRetrospective Studiesbusiness.industryLASIKMiddle AgedLaserAblationeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeFemtosecondFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Short-Term Impact of FS-LASIK and SMILE on Dry Eye Metrics and Corneal Nerve Morphology

2020

PURPOSE To analyze the short-term (up to 1 month) clinical outcomes in patients undergoing corneal laser refractive surgery and the impact on dry eye disease (DED) metrics and corneal nerves using in vivo confocal microscopy (IVCM). METHODS The unaided distance visual acuity, corrected distance visual acuity, and spherical equivalent refraction (SEQ) were determined in 16 and 13 patients undergoing FS-LASIK and SMILE, respectively. DED metrics assessed were Ocular Surface Disease Index, Dry Eye Questionnaire 5-items (DEQ-5), tear film osmolarity, tear meniscus height, noninvasive keratograph breakup time (NIKBUT), ocular staining, and meibomian gland atrophy. An automated analysis of cornea…

AdultMalemedicine.medical_specialtyTime FactorsVisual acuitygenetic structuresCorneal nervemedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMeibomian glandKeratomileusisRefraction OcularCornea03 medical and health sciencesNerve Fibers0302 clinical medicineAtrophyRefractive surgeryOphthalmologymedicineHumansOcular Surface Disease IndexProspective StudiesMicroscopy Confocalbusiness.industryLASIKmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryDry Eye SyndromesFemaleLasers Excimersense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up StudiesCornea
researchProduct

Choice of spatial frequency for contrast sensitivity evaluation after corneal refractive surgery.

2002

ABSTRACT PURPOSE: To study the utility of measurements of contrast sensitivity at different spatial frequencies as an index of visual recovery following refractive surgery. METHODS: Contrast sensitivity at 1.5, 3, 6, 12, and 18 c/deg was measured with the Stereo Optical FACT chart in 20 patients after photorefractive keratectomy (PRK) using the Nidek EC-5000 excimer laser system, and in 18 patients following laser in situ keratomileusis (LASER). Contrast sensitivity was measured preoperatively and 1, 3, 6, and 12 months after surgery. RESULTS: Results showed a statistically significant reduction (P<01) in contrast sensitivity at all spatial frequencies in PRR patients during the first an…

AdultMalemedicine.medical_specialtyTime Factorsgenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityKeratomileusisExcimerPhotorefractive Keratectomylaw.inventionContrast SensitivityCornealawOphthalmologyRefractive surgerymedicineMyopiaContrast (vision)Humansmedia_commonbusiness.industryLASIKLasereye diseasesPhotorefractive keratectomySurgeryOphthalmologySurgeryFemaleLasers Excimersense organsSpatial frequencybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Early clinical outcomes after small incision lenticule extraction surgery (SMILE)

2018

Abstract Purpose Dry eye is known to impact on clinical outcomes after laser vision correction and the use of a newer ‘all femtosecond laser’ surgical approach may be associated with less impact on the ocular surface post-operatively. The purpose of this study was to evaluate the early clinical outcomes and tear instability after the first small incision lenticule extraction (SMILE) cases undertaken by three surgeons at a single site in the UK. Methods Retrospective audit. Seventy-one eyes of 37 patients underwent SMILE surgery using the Zeiss VisuMax laser system (Carl Zeiss Meditec, Germany). Uncorrected and corrected distance visual acuity, spherical equivalent refraction, fluorescein en…

AdultMalemedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresCorneal Surgery LaserCorneal StromaVisual AcuityRefraction Ocularlaw.invention03 medical and health sciences0302 clinical medicineSingle sitelawOphthalmologyMyopiamedicineHumansSmall incision lenticule extractionSmile surgeryRetrospective StudiesSurgical approachKeratometerbusiness.industryCorneal TopographyGeneral Medicineeye diseasesSurgeryOphthalmologyTears030221 ophthalmology & optometryFemaleLasers Excimersense organsmedicine.symptombusinessOcular surface030217 neurology & neurosurgeryOptometry
researchProduct

Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials.

2011

Purpose To examine differences in efficacy, accuracy, safety, and changes in aberrations between femtosecond and mechanical microkeratome laser in situ keratomileusis (LASIK) for myopia. Setting Department of Ophthalmology, Shanghai First People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China. Design Evidence-based manuscript. Methods Data sources, including PubMed, Medline, EMBASE, and Cochrane Controlled Trials Register, were searched to identify potentially relevant prospective randomized controlled trials. Primary outcome measures were efficacy (uncorrected distance visual acuity ≥20/20), accuracy (±0.50 diopter mean spherical equivalent), and safety (loss of ≥2 l…

Adultmedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresDatabases Factualmedicine.medical_treatmentCorneal StromaKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSensitivity and Specificitylaw.inventionYoung AdultPostoperative ComplicationsRandomized controlled triallawMicrokeratomemedicineMyopiaHumansRegistriesDioptreRandomized Controlled Trials as TopicEquipment Safetybusiness.industryLASIKReproducibility of ResultsOdds ratioMiddle Agedeye diseasesSensory SystemsConfidence intervalSurgeryOphthalmologyTreatment OutcomeMeta-analysisSurgeryLasers ExcimerbusinessJournal of cataract and refractive surgery
researchProduct

Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser

2011

PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens gro…

Adultmedicine.medical_specialtyCorneal endotheliumgenetic structuresEndotheliummedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCell CountKeratomileusisRefraction OcularYoung AdultOphthalmologyMyopiamedicineHumansProspective StudiesDioptrebusiness.industryEndothelium CornealLASIKCorneal Endothelial Cell LossContact Lenses Hydrophiliceye diseasesSurgeryContact lensOphthalmologymedicine.anatomical_structureLens (anatomy)FemtosecondLasers ExcimerSurgerysense organsbusinessJournal of Refractive Surgery
researchProduct

Excimer laser atherectomy in an uncrossable long chronic total occlusion through the subintimal space

2020

We present a successfully chronic total occlusions (CTO) coronary recanalisation with the subadventitial space by excimer laser atherectomy (ELCA) adjunctive therapy. Angiogram revealed non-significant diffuse disease of the left coronary system with a complex long proximal right coronary artery (RCA) CTO (J-CTO score 4) and collaterals (Rentrop Grade 2 and Werner classification CC1) from the septal branches (Figure 1, Panel A). CTO PCI of the RCA was then indicated and planned. Initially, antegrade approach and a retrograde approach technique were attempted without success. Thereafter, a rescue Antegrade Dissection Reentry strategy (ADR) was applied. A Pilot 200 (Abbott) was advanced in a …

Atherectomy Coronarymedicine.medical_specialtyAtherectomymedicine.medical_treatmentstent expansionCoronary AngiographyTotal occlusionintravascular ultrasoundAtherectomyIntravascular ultrasoundmedicineHumanscardiovascular diseaseschronic total occlusionmedicine.diagnostic_testExcimer laserbusiness.industrypercutaneous coronary interventionPercutaneous coronary interventionGeneral MedicineTreatment OutcomeCoronary OcclusionChronic DiseaseLasers ExcimerRadiologyExcimer laser coronary atherectomyCardiology and Cardiovascular MedicinebusinessExcimer laser coronary atherectomyActa Cardiologica
researchProduct

Excimer laser technology in percutaneous coronary interventions: Cardiovascular laser society's position paper

2022

Excimer Laser Coronary Atherectomy (ELCA) is a well-established therapy that emerged for the treatment of peripheral vascular atherosclerosis in the late 1980s, at a time when catheters and materials were rudimentary and associated with the most serious complications. Refinements in catheter technology and the introduction of improved laser techniques have led to their effective use for the treatment of a wide spectrum of complex coronary lesions, such as thrombotic lesions, severe calcific lesions, non-crossable or non-expandable lesions, chronic occlusions, and stent under-expansion. The gradual introduction of high-energy strategies combined with the contrast infusion technique has enabl…

Chronic occlusionAtherectomy CoronaryTechnologyAtherectomySevere calcific lesionChronic occlusions; ELCA; Laser angioplasty; Severe calcific lesions; Stent under-expansion; Thrombotic lesions; Coronary Angiography; Humans; Lasers Excimer; Technology; Treatment Outcome; Atherectomy Coronary; Percutaneous Coronary InterventionLasersCoronaryThrombotic lesionCoronary AngiographyChronic occlusionsExcimerTreatment OutcomePercutaneous Coronary InterventionStent under-expansionSevere calcific lesionsHumansLaser angioplastyLasers ExcimerELCACardiology and Cardiovascular MedicineThrombotic lesionsHumanInternational Journal of Cardiology
researchProduct

Intraocular pressure measurements during flap preparation using 2 femtosecond lasers and 1 microkeratome in human donor eyes

2012

Purpose To evaluate and compare intraocular pressures (IOPs) during flap preparations performed using 2 femtosecond lasers and a mechanical microkeratome in human donor globes. Setting University Medical Center Mainz, Mainz, and Euroeyes Clinic Stuttgart, Stuttgart, Germany. Design Experimental study. Methods A cannula was inserted through the optic nerve in human globes. The IOP was obtained continuously during flap preparation using the 60 kHz Intralase femtosecond laser, the 200 kHz Visumax femtosecond laser, or the Amadeus II microkeratome. For each experiment, a normal lamellar flap preparation (regular procedure) and a worst-case procedure (femtosecond laser interface was pressed agai…

Intraocular pressureMaterials sciencebusiness.industryCorneal StromaKeratomileusis Laser In SituLaserModels BiologicalSurgical FlapsTissue DonorsSensory Systemslaw.inventionTonometry OcularOphthalmologyOpticslawMicrokeratomeFemtosecondHumansLasers ExcimerSurgeryUniversity medicalbusinessIntraocular PressureJournal of Cataract and Refractive Surgery
researchProduct