Ocular Surface and Tear Film Changes in Older Women Working with Computers
2015
The aim of this work is to investigate changes in the ocular surface (OS) and tear film (TF) by means of questionnaire-based subjective symptoms, TF break-up time, Schirmer test, and TF analysis in women working with computers and to analyze the effects of the oral supplementation with antioxidants/omega 3 fatty acids (A/ω3) in the OS outcomes. Women aged 40–65 years (n=148) were recruited at the Administrative Offices of Valencia (Spain) and distributed into two age groups, 40–52 years (AGE1;n=87) and 53–65 years (AGE2;n=61), and then subdivided according to being (or not) computer users (CUG; NCUG) during the workday. Homogeneous subgroups were randomly assigned (or not) to the daily inta…
Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT
2021
Purpose To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). Methods We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. Results Mean LV wa…
OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers
2011
PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…
Online Vs In-person Education: Evaluating the Potential Influence of Teaching Modality on Dry Eye Symptoms and Risk Factors During the COVID-19 Pande…
2021
OBJECTIVES: To assess the potential effects of switching to online lecture format on dry eye symptoms and dry eye disease (DED) risk factors. METHODS: An anonymous cross-sectional online survey was conducted in 812 university students (mean age, 21.5±4.0 years). Participants were classified according to the number of hours the participants took online lectures into online students or in-person students. Respondents completed a total of three DED questionnaires (Ocular Surface Disease Index [OSDI]; 5-item Dry Eye Questionnaire; 8-item Contact Lens Dry Eye Questionnaire) and were surveyed on dry eye risk factors contemplated by the Tear Film and Ocular Surface Society Dry Eye Workshop II in a…
Diagnostic Capability of a New Objective Method to Assess Meibomian Gland Visibility
2021
SIGNIFICANCE The diagnosis of dry eye disease and meibomian gland dysfunction (MGD) is challenging. Measuring meibomian gland visibility may provide an additional objective method to diagnose MGD. PURPOSE This study aimed to evaluate the ability of new metrics to better diagnose MGD, based on measuring meibomian gland visibility. METHODS One hundred twelve healthy volunteers (age, 48.3 ± 27.5 years) were enrolled in this study. Ocular surface parameters were measured using the Oculus Keratograph 5M (Oculus GmbH, Wetzlar). Subjects were classified according to the presence or absence of MGD. New metrics based on the visibility of the meibomian glands were calculated and later compared betwee…
Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.
2007
Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…
Laser treatment of giant xanthelasma palpebrarum
2013
Xanthelasma palpebrarum is the most common cutaneous xanthoma. It typically presents in middle-aged and older adults, most often around the eyelids. The diagnosis is made clinically. Giant xanthelasmas palpebrarum are xanthelasmas that extensively affect the superior and inferior bilateral eyelids. Many techniques have been put forward for treating these lesions (surgical, laser, and chemical techniques), but we describe our experience in the treatment of giant xanthelasmas by ultrapulsed CO2 laser. Between 2009 and 2012, in the Division of Plastic and Reconstructive Surgery at the University of Palermo, 12 patients with giant xanthelasmas were treated using a CO2 laser. The laser parameter…
Evaluation of the MGDRx eyebag treatment in young and older subjects with dry eye symptoms
2021
Summary Objectives This study aims to evaluate the relationship between application of the MGDRx thermal eyebag and dry eye signs and symptoms in young and older subjects and to compare the results between the two groups. Methods Thirty young, healthily volunteers between 18 and 31 years of age (23.95 ± 3.94 years) and thirty older subjects between 61 and 90 years of age (77.97 ± 8.11 years) participated in this study. Ocular surface parameters were assessed using the Oculus Keratograph 5 M, following the guidelines of the Tear Film and Ocular Surface Dry Eye Workshop II Diagnostic Methodology report. Only subjects with a positive score on at least one questionnaire and an initial Non-Invas…
The effect of simulated normal and amblyopic higher-order aberrations on visual performance.
2012
Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …
Eye position tunes the contribution of allocentric and egocentric information to target localization in human goal-directed arm movements.
1997
Subjects were required to point to the distant vertex of the closed and the open configurations of the Muller-Lyer illusion using either their right hand (experiment 1) or their left hand (experiment 2). In both experiments the Muller-Lyer figures were horizontally presented either in the left or in the right hemispace and movements were executed using either foveal or peripheral vision of the target. According to the illusion effect, subjects undershot and overshot the vertex location of the closed and the open configuration, respectively. The illusion effect decreased when the target was fixated and when the stimulus was positioned in the right hemispace. These results confirm the hypothe…