Search results for " Eye"

showing 10 items of 383 documents

The posterior chamber phakic refractive lens (PRL): a review

2012

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…

Phakic Intraocular Lensesmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentVisual performanceOptical qualityReviewAstigmatismRefraction OcularPhakic intraocular lensPhakic refractive lens (PRL)CataractPupilEndophthalmitisLens Implantation IntraocularCataractsOphthalmologyRefractive surgeryMyopiamedicineHumansRefractive surgeryÓpticaPosterior chamber phakic intraocular lensbusiness.industryPatient SelectionEquipment Designmedicine.diseaseeye diseasesOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Posterior Capsule of the LensOptometrysense organsbusinessEye
researchProduct

Acute effects of low doses of methyl parathion on human EEG.

2005

Abstract Biological monitoring of workers exposed to organophosphates consists mainly of measuring serum or erythrocyte cholinesterase activity. However, animal experiments and a field study suggest that quantitative analysis of EEG may be more sensitive. In a parallel group design, 25 farmers were investigated, spraying methyl parathion or water for 50 min. EEG was recorded before and after spraying. Serum and erythrocyte cholinesterase activity was compared with intraindividual pre-exposure values. Plasma methyl parathion concentrations ranged up to 12.1 μg/l, methyl paraoxon was not detectable. Based on plasma concentrations, two exposed subgroups were defined. In EEG recorded with close…

PharmacologyAcute effectsmedicine.medical_specialtyParaoxonbiologymedicine.diagnostic_testHealth Toxicology and MutagenesisLow doseGeneral MedicineElectroencephalographyToxicologychemistry.chemical_compoundEndocrinologychemistryAnesthesiaInternal medicineClosed eyesmedicineParathion methylbiology.proteinQuantitative analysis (chemistry)medicine.drugCholinesteraseEnvironmental toxicology and pharmacology
researchProduct

Wahrnehmung polarisierten Lichtes durchEupagurus

1950

(1)Eupagurus bernhardus has in its compound eye an apparatus that can distinguish polarized light like an analysator. (2) This extinction does not apply to all the polarized light, but only a certain amount of it, this may be concluded from the fact that in the former experiments the strength of vision in no case became zero. (3) Probably the analysator in the eye ofEupagurus functions as an extinguisher of the disturbing polarized light, for the sunlight reflected from the surface of water is polarized to an ample extent.

PharmacologySunlightPhysicsCellular and Molecular NeuroscienceOpticsExtinction (optical mineralogy)business.industryMolecular MedicineCell BiologyCompound eyebusinessMolecular BiologyExperientia
researchProduct

Lobster eye optics for nano-satellite x-ray monitor

2011

The Lobster eye design for a grazing incidence X-ray optics provides wide field of view of the order of many degrees, for this reason it would be a convenient approach for the construction of space X-ray monitors. In this paper, we compare previously reported measurements of prototype lobster eye X-ray optics called P-25 with computer simulations and discuss differences between the theoretical end experimentally obtained results. Usability of this prototype lobster eye and manufacturing technology for the nano-satellite mission is assessed. The specific scientific goals are proposed.

PhysicsManufacturing technologyOpticsSettore FIS/05 - Astronomia E AstrofisicaNano satellitebusiness.industryX-ray opticsX-ray telescopeUsabilityLobster Eye X-ray optics X-ray telescope X-ray sky monitor X-ray imaging X-raybusinessWide field
researchProduct

Tests of Lobster Eye Optics for Small Space X-ray Telescope

2011

Abstract The Lobster eye design for a grazing incidence X-ray optics provides wide field of view of the order of many degrees, for this reason it can be a convenient approach for the construction of space all-sky X-ray monitors. We present preliminary results of tests of prototype lobster eye X-ray optics in quasi parallel beam full imaging mode conducted using the 35 m long X-ray beam-line of INAF-OAPA in Palermo (Italy). X-ray images at the focal plane have been taken with a microchannel plate (MCP) detector at several energy values from 0.3 to 8 keV. The gain, the field of view and the angular resolution have been measured and compared with theoretical values.

PhysicsNuclear and High Energy Physicsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaDetectorX-ray opticsField of viewX-ray telescopeCardinal pointOpticsLobster eye X-ray optics X-ray telescope All-sky monitor X-ray imaging X-raySettore FIS/05 - Astronomia E AstrofisicaAngular resolutionMicrochannel plate detectorbusinessInstrumentationEnergy (signal processing)
researchProduct

ERRATUM: "Search for High-Energy Muon Neutrinos from the "Naked-Eye" GRB 080319B with the Icecube Neutrino Telescope" (2009, ApJ, 701, 1721)

2009

We have noticed some mistakes in formulae (A2) and (A5) in the appendix of our paper. The errors are not present in the code used in the analysis and hence none of the plots or results is affected. The correct formulae are below.

Physics[PHYS.ASTR.HE]Physics [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]Muon[SDU.ASTR.CO]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]Solar neutrino[SDU.ASTR.HE]Sciences of the Universe [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]AstronomyAstronomyAstronomy and AstrophysicsAstrophysicsSolar neutrino problem01 natural sciences[PHYS.ASTR.CO]Physics [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]Neutrino detectorSpace and Planetary Science0103 physical sciencesNaked eyeNeutrinoNeutrino astronomy010306 general physicsGamma-ray burstGeneralLiterature_REFERENCE(e.g.dictionariesencyclopediasglossaries)
researchProduct

Analytical description of lobster eye and similar multi-foil optics

2015

Analytical equations describing lobster eye optical parameters on dependence on its geometric parameters are presented. The paper partially gives review of main previously known results. At next, the paper gives new results discussing parameters, that were not included to previously published models but may be significant. The results are applicable for a Schmidt as well as for an Angel lobster eye and for some related multi-foil systems.

Physicsbusiness.industryx-ray opticElectronic Optical and Magnetic Materialmulti-foil opticgrazing incidence opticX-ray opticsAnalytical equationsComputer Science Applications1707 Computer Vision and Pattern RecognitionCondensed Matter PhysicsApplied MathematicOpticslobster eyeElectrical and Electronic Engineeringbusinessreflective opticFOIL method
researchProduct

Detection of wave aberrations in the human eye using a retinoscopy-like technique

2006

The influence of optical aberrations on the retinoscopic reflex is theoretically analyzed from a geometrical point of view. The relationship between the wave aberrations to the ray aberrations is applied to explain the appearance of the retinoscopic patterns for different types of ocular aberrations. Several schematic models of the human eye are tested numerically, showing that a careful retinoscopic examination can detect the usual eye aberrations.

Physicsgenetic structuresmedicine.diagnostic_testbusiness.industryeye diseasesAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsAberrations of the eyeOpticsmedicine.anatomical_structuremedicineHuman eyesense organsElectrical and Electronic EngineeringPhysical and Theoretical ChemistrybusinessRetinoscopyOptical aberrationOptics Communications
researchProduct

General principles in motion vision: Color blindness of object motion depends on pattern velocity in honeybee and goldfish

2011

AbstractVisual systems can undergo striking adaptations to specific visual environments during evolution, but they can also be very “conservative.” This seems to be the case in motion vision, which is surprisingly similar in species as distant as honeybee and goldfish. In both visual systems, motion vision measured with the optomotor response is color blind and mediated by one photoreceptor type only. Here, we ask whether this is also the case if the moving stimulus is restricted to a small part of the visual field, and test what influence velocity may have on chromatic motion perception. Honeybees were trained to discriminate between clockwise- and counterclockwise-rotating sector disks. S…

PhysiologyColor visionMotion PerceptionColorColor Vision DefectsBiologyStimulus (physiology)Discrimination PsychologicalGoldfishAnimalsComputer visionCompound Eye ArthropodMotion perceptionChromatic scaleVision OcularCommunicationbusiness.industryCompound eyeBeesSensory SystemsVisual fieldPattern Recognition VisualColor Vision DefectsOptomotor responsePhotoreceptor Cells InvertebrateArtificial intelligencebusinessColor PerceptionPhotic StimulationPhotoreceptor Cells VertebrateVisual Neuroscience
researchProduct

Differential electrodermal and phasic heart rate responses to personally relevant information: Comparing sleep and wakefulness

2010

This study examined autonomic physiological responses to personally relevant information presented during sleep and wakefulness. Heart rate and electrodermal reactions to subjects’ own first name and other first names were measured during sleep stage 2, rapid eye movement (REM) sleep, and wakefulness. Across all conditions, larger skin conductance responses were elicited by subjects’ own first name. During REM sleep, personally relevant information led to larger heart rate acceleration, whereas an enhanced deceleration was examined during wakefulness. These findings suggest that auditory information is processed on a semantic level even during sleep. However, personally relevant information…

PhysiologyEye movementStimulus (physiology)Non-rapid eye movement sleepDevelopmental psychologyOrienting responseAutonomic nervous systemNeuropsychology and Physiological PsychologyNeurologyPhysiology (medical)WakefulnessPsychologyNeuroscienceNeuroscience of sleeppsychological phenomena and processesSlow-wave sleepSleep and Biological Rhythms
researchProduct