Search results for " FIX"
showing 10 items of 575 documents
Open Reduction and Internal Fixation of Low Subcondylar Fractures of Mandible Through High Cervical Transmasseteric Anteroparotid Approach
2009
Purpose The aim of the present study was to evaluate the functional and radiologic results of low subcondylar fracture fixation with modus TCP plates (Medartis, Basel, Switzerland) using a high cervical transmasseteric anteroparotid approach. Materials and Methods A prospective study was designed, enrolling all minimum-aged 15-year-old echomorphology patients presenting with displaced low subcondylar fracture with occlusion disturbances during a 41-month period. All fractures were fixed with modus TCP plates using high cervical transmasseteric anteroparotid approach. All patients underwent immediate physiotherapy and a 6-week liquid and semiliquid feeding period. Clinical and radiologic exa…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Patients requiring interruption of long-term oral anticoagulant therapy: the use of fixed sub-therapeutic doses of low-molecular weight heparin.
2009
Introduction: We tested the efficacy and safety of fixed doses of Low-Molecular Weight Heparin (LMWH) in patients requiring interruption of Vitamin-k Antagonist (VKA) because of invasive procedures Methodology: Pre-operatively, patients discontinued VKA 5 +/- 1days; in those at low-risk for thrombosis, LMWH was given at a prophylactic dosage of 3.800 U.I. (nadroparin) or 4.000 U.I. (enoxaparin) anti-FXa once daily the night before the procedure. In patients at high-risk for thrombosis, LMWH was started early after VKA cessation and given at fixed sub-therapeutic doses (3.800 or 4.000 UI anti-FXa twice daily) until surgery. Post-operatively, LMWH was reinitiated 12 hours after procedure whil…
Indications and limitations of the fixator TGF “Gex-Fix” in proximal end humeral fractures
2014
Abstract The incidence of fractures of the humerus has increased exponentially in recent years. The most used classifications for humerus fracture are morphological (Neer), biological (AO/ASIF) and descriptive (Hertel). The types of surgical treatment for humerus fracture include prosthetic replacement and synthesis using different devices, including the Tension Guide Fixator (TGF), Gex-Fix. External fixation for displaced proximal humeral fractures avoids dissection and soft tissue stripping and has been reported by some authors to be associated with higher union rates, a lower incidence of avascular necrosis, less scarring of the scapulohumeral interface, and faster rehabilitation compare…
Modified fixation free plug technique using a new 3D multilamellar implant for inguinal hernia repair: a retrospective study of a single operator cas…
2013
Aim: Implant fixation, mesh shrinkage and poor quality of tissue ingrowth are unresolved issues in modern hernia repair. Many complications reported in the literature such as bleeding, nerve entrapment, hematoma, pain, discomfort, and testicular complications, are considered to be a direct results of implant fixation. This article describes the outcomes of a procedure carried out using a handcrafted implant that addresses the issues consequent to point fixation. Methods: This was a retrospective study on the short, medium and long-term results of placing a-modified, fixation free three-dimensional polypropylene implant in 61 patients who underwent inguinal hernia repair using a novel delive…
New mesh shape and improved implantation procedure to simplify and standardize open ventral hernia repair: a preliminary report.
2010
Introduction Issues in ventral hernia repair are represented by the need for mesh fixation and how to assure a sufficient mesh overlap of the defect. Aiming to resolve these problems, this study describes a modified technique for ventral and incisional hernia repair based upon a newly developed mesh with a special design. This new type of implant allows broader coverage of the abdominal wall and results in tension- and fixation-free repair. Materials and methods A unique geometrically shaped mesh consisting of a large central body and radiating arms was used to repair ventral or incisional hernia. The mesh was intended not to be point-fixated. The friction of the straps passing through the …
Clinical performance of a new medullary humeral nail: antegrade versus retrograde insertion.
2001
Objective A new intramedullary nail system for humeral shaft fractures is evaluated to determine whether retrograde nailing is as reliable as antegrade nailing. Study design Prospective multicenter nonrandomized clinical study. Patients Eighty-four patients with acute humeral shaft fractures were nailed with the new unreamed humeral nail (UHN) system. Fifty-seven nails were introduced retrogradely, and twenty-seven antegradely. Bone healing and functional outcome were the follow-up parameters. Results The ratio of perioperative complications was equivalent for both groups, but one shaft fracture and three fractures or fissures at the entry point occurred in the group with retrograde nail in…
Functional results after operative treatment of olecranon fractures.
2004
In a retrospective, nonrandomized study, we reviewed our experience with the operative treatment of olecranon fractures to find out which factors correlate with subjective complaints and functional outcome. A total of 95 consecutive olecranon fractures were operatively treated in our level I trauma institution between March 1, 1992 and March 1, 2000. Medical charts and radiographs of all patients were evaluated. Three patients died, 23 were lost to follow-up. Fifty-eight of 69 available patients (84.0%) were reviewed clinically and/or radiologically after a mean time interval of 36 months. Fracture type, fracture classification, associated lesions, technical correctness of osteosynthesis, a…
Olecranon fractures in adults: factors influencing outcome.
2003
In a retrospective, non-randomized study, we reviewed our experience with the operative treatment of olecranon fractures to find out which factors correlate with subjective complaints and functional outcome. A total of 95 consecutive olecranon fractures were operatively treated in our level I trauma institution between 1 March 1992 and 1 March 2000. Medical records and X-rays of all patients were evaluated. Three patients died, 23 were lost to follow-up. Fifty-eight of 69 available patients (84.0%) were reviewed clinically and/or radiologically after a mean time of 36 months. Fracture type, fracture classification, associated lesions, technical correctness of osteosynthesis, age and comorbi…
The treatment of wrist fractures with Epibloc System
2011
BACKGROUND Fractures of the distal extremity of the radius are the most common bone lesions of the superior extremity of the body, representing 17% of the fractures treated in First Aid facilities. The restoration of anatomical relationships in the radiocarpal joint is considered to be a prerequisite for good functional recovery. There are numerous methods of treatment of these fractures. The Epibloc system is a percutaneous endomedullary synthesis alternative to the plaster cast in wrist fracture treatment. MATERIALS AND METHODS The authors describe their experience with 81 fractures (63 type A2-3 fractures and 18 type C1) of the wrist treated with the Epibloc System (ES). The results were…