Search results for " Fault"
showing 10 items of 239 documents
Architecture and kinematics of forearc basins and intra-caldera resurgences: new insight from the Paola Basin (western offshore Calabria region) and …
This thesis deals with the patterns of tectonic deformation at different time and spatial scales ranging from tens to millions of years and from one to tens of kilometers, respectively. The study areas are the Campi Flegrei (Campania region, Italy) and Paola Basin (western offshore Calabria region, Italy). The Campi Flegrei and its offshore prolongation, the Pozzuoli Bay, are a laboratory for investigating volcano-tectonic deformations at 1yr-1kyr timescale and 1km spatial scale related to the dynamics of the Neapolitan Yellow Tuff (NYT) caldera and its intra-caldera resurgence. Resurgence is the late stage, long-term uplift of a collapse caldera floor to form a dome-like structure. The com…
Deformation mechanism and hydraulic properties of normal and strike-slip fault zones in porous carbonates outcropping in central and southern Italy.
2013
Deformation of porous carbonate grainstones takes generally place by compactive shear banding, which initially produce single bands that may evolve during incremental strain into zones of multiple bands and, eventually, fault zones with discrete slip surfaces. The several processes associated to increased deformation are recorded in the aforementioned structural elements. In fact, they are characterized by a different texture, porosity, dimensional attributes (length, thickness, displacement). Fault zones are characterized by inner fault cores made of cataclastic material surrounded by thicker damage zones including single bands and zones of bands. In this work, we present the results of in…
Neotectonic uplift and tilting of crustal blocks in Northern Sicily
2009
La Sicilia settentrionale è caratterizzata da un’intensa attività sismica che è espressione di deformazioni attive. In questo settore dell’Isola affiora il nucleo della catena neogenica delle Magrebidi occidentali, che è sottoposto ad intenso sollevamento durante il Plio-Pleistocene. Le deformazioni più recenti sono, in gran parte, rappresentate da sistemi di faglie estensionali e trascorrenti. Il tasso di sollevamento non è uniforme, così come suggerisce la differente elevazione dei depositi di questo periodo. Essi affiorano lungo il settore costiero settentrionale e la loro quota decresce complessivamente dall’estremità nord-est a quella nord-ovest della Sicilia. Le deformazioni più recen…
Multi-scale properties of strike-slip faults corss-cutting the Pleistocene carbonate grainstones of Favignana Island (NW Sicily, Italy)
2010
A Multidisciplinary approach to define the Plio-Quaternary tectonics in the Termini Imerese Mts. (Northern central Sicily)
2012
Development of “Design of Experiments” for modelling direct expansion air-conditioning systems under variable cooling loads and faulty operating cond…
2019
Air conditioning systems are widely adopted in the building sector and are generally responsible for high energy consumption. Part of this consumption is related to the poor maintenance adopted by plant owner over time, which causes energy performance degradation. Typical faults, such as fouling or improper refrigerant charge have been shown to heavily impact on energy consumption of these systems. In order to support cost-effective maintenance schedule, Fault Detection and Diagnosis Technique are under investigation in the world. However, in order to devise a diagnostic method a preliminary modelling of air conditioning system is due. To this aim, a test procedure which requires the least …
On the reliability of thermoeconomic diagnosis of fouled evaporators: assessing the influence of geometries, operating conditions and reference state
2015
Thermoeconomic diagnosis of refrigeration systems is a pioneeristic approach, which has been proven to achieve good performances (under favorable conditions) for the detection of specific faults such as condenser and evaporator fouling and compressor valve leakage. In this paper the sensitivity of performance in detecting fouled Direct Expansion (DX) coils is investigated; the examined parameters are the temperature and relative humidity of coil inlet air and the sensible/latent heat ratio of the coil (varied by considering different numbers of rows). As the thermoeconomic model requires splitting the specific exergy of cooling air into “mechanical”, “thermal” and “chemical” fractions, and …
Safety Concerns on Ground Fault Application Transfer Phenomenon in HV Installations
2007
When a fault to ground occurs in HV/MV substations supplied by a combined overhead-cable line, most of the fault current can be transferred and injected into the soil several kilometers far away from the fault location. This phenomenon is called "fault application transfer" and mostly concerns transition stations, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, usually accessible to the general public, the local ground electrode could be inadequate to maintain ground potential rise within safety limits. Hence, dangerous touch and step voltages may appear at exposed locations. In the paper results of various computer simulations …
A New Mathematical Approach for Faults Identification and Location in Distribution Systems
2009
The paper presents a new methodology for fault identification and location in electrical distribution systems, based on the use of a lumped parameter representation of the faulted line and on a matrix approach. Utilities are quite interested in such items, since the new required quality standards put severe constraints on faults management and clearance.
Results of the research on global earthing systems: A contribution to the problem of their identification
2013
The paper presents a study on the factors that can have influence on the rise of a Global Earthing System. The first part of the work deals with: - the definition of proximity, interconnection and quasi-equipotential; - the influence of the presence of HV/MV stations on the dangerous voltages and on the permissible voltage limits; - the dependence of the hazardous condition for persons on the different kind of fault; - the effects on safety of the coexistence of HV, MV and LV systems. In the second part, starting from the discussion on the themes above-mentioned and on the results of the studies, measurement campaigns and simulations on interconnected earthing systems done in the last fifte…