Search results for " Fault"
showing 10 items of 239 documents
Vibration signature analysis for rotor broken bar diagnosis in double cage induction motor drives
2013
The paper investigates the diagnosis of rotor broken bars in field oriented controlled (FOC) double cage induction motor drives, using current and vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of asymmetries in the machine are based on the signature analysis of electrical variables. The proposed diagnosis approach is based on optimized use of wavelet analysis by a pre-processing of phase current or axial/radial vibration signals. Thus, the time evolution of the tracked rotor fault components can be effectively analyzed. This paper shows also the relevance of the fault components computed from axial vibration sign…
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Reducing DC Link Voltage Unbalance in a Fault-Tolerant Inverter
2014
Today, continuous working of power inverter drives is mandatory for several applications. Damages to materials, machines or even risks to human life have to be absolutely avoided. In the literature, fault-tolerant algorithms and architectures to achieve a successful fault handling are investigated. Researchers aim at reducing the number and cost of additional components, improving at the same time the inverter performances under postfault conditions. Cost, post-fault power derating and increasing distortion are usually conflicting requirements. In this paper, a fault-tolerant three phase inverter is presented. A reconfigurable architecture and a novel fault-tolerant algorithm is designed to…
Effects of double ground faults in Wind Farms collector cables
2015
Medium Voltage collector cables of Wind Farms have metal shields connected to the grounding systems of the towers and of the connection station. Thanks to this bonding, when a ground fault occurs, the fault current splits itself among all the grounding systems of the wind farm, this causing a reduction of the ground potential rise at the fault location. Nevertheless, in presence of double ground faults, very high ground potential rises occur at the two fault locations and safety against electric shock is not always assured. In order to study this issue, the paper presents a model for simulating in a simple way the effects of double ground faults occurring in Medium Voltage collectors of ext…
Development of Diagnostic Systems for the Fault Tolerant Operation of Micro-Grids
2010
The progressive penetration level of Distributed Generation (DG) is destined to cause deep changes in the existing distribution networks no longer considered as passive terminations of the whole electrical system. A possible solution is the realization of small networks, namely the Micro-Grids, reproducing in themselves the structure of the main production and distribution of the electrical energy system. In order to gain an adequate reliability level of the micro-grids the individuation and the management of the faults with the goal of maintaining the micro-grid operation (fault tolerant operation) is quite important. In the present paper after the introduction of the aims of several diagn…
A review of multiple faults diagnosis methods in Voltage Source Inverters
2015
This paper examines, as in short review, the methods of diagnosis of simple and multiple faults on Voltage Source Inverter (VSI). The methods examined here are essentially based on the inspection of the load currents. Some of these diagnosis methods are characterized by low computational effort, other for a better reliability avoiding faultless positive tests. Some solutions are characterized by a share of these benefits while others prefer an enforcement of trustworthiness, in spite of the lower calculation amount. The analysis of the technical literature, certainly, offers a glimpse about the creation of new algorithms and significant advances for the future.
An efficient diagnostic technique for distribution systems based on under fault voltages and currents
2010
Service continuity is one of the major aspects in the definition of the quality of the electrical energy, for this reason the research in the field of faults diagnostic for distribution systems is spreading ever more. Moreover the increasing interest around modern distribution systems automation for management purposes gives faults diagnostics more tools to detect outages precisely and in short times. In this paper, the applicability of an efficient fault location and characterization methodology within a centralized monitoring system is discussed. The methodology, appropriate for any kind of fault, is based on the use of the analytical model of the network lines and uses the fundamental co…
The Global Grounding System: Definitions and guidelines
2015
The present paper presents the preliminary results of the ongoing Italian METERGLOB project on the contribution given by the exposed conductive parts to a Global Grounding System. One of the expected results of METERGLOB is to carry out guidelines for the identification of a Global Grounding System. These guidelines must be defined on the basis of the definitions and methods present in the current international standards on grounding and safety. In the paper some definitions and elements to be taken into account for the identification of a Global Grounding System are given.
A Geometrical Simple Approach for Power Silicon Devices Fault Detection and Fault-Tolerant Operation of a Voltage Source Inverter
2012
Fault-tolerant converters have been widely investigated for years and nowadays an extensive technical literature on this field exists. This paper presents a novel fault detection algorithm based on a simple geometrical approach. In the algorithm analysis both the case of faults in single device and the lose of an entire inverter leg have been considered. False positive detections are avoided by considering a proper number of current samples. The proposed fault detection algorithm is characterized by simplicity, low computational and implementation effort with a consequent enough fast execution, easy control integration with the possibility to use it both in hardware in the loop systems and …
A suitable control technique for fault-tolerant converters in Distributed Generation
2011
The penetration of Distributed Generation (DG) in power systems is deeply changing the existing distribution networks which is becoming a very sophisticated and complex systems incorporating both active (generators) and passive systems (distribution systems, converters and loads). The necessary simplification can be obtained dealing with small networks, namely Micro-Grids, reproducing, in a smaller scale, the structure and the problems of large networks including production, transmission and distribution of the electrical energy. In order to achieve an adequate level of reliability, fault-tolerant operations of micro-grids become very important. This result can be achieved only using power …