Effectiveness and safety of electrical cardioversion for acute-onset atrial fibrillation in the emergency department: a real-world 10-year single cen…
2019
OBJECTIVE Despite limited evidence, electrical cardioversion of acute-onset atrial fibrillation (AAF) is widely performed in the emergency department (ED). The aim of this study was to describe the effectiveness and safety of electrical cardioversion of AAF performed by emergency physicians in the ED. METHODS All episodes of AAF electrically cardioverted in the ED were retrieved from the database for a 10-year period. Most patients not already receiving anticoagulants were given enoxaparin before the procedure (259/419). Procedural complications were recorded, and the patients were followed-up for 30 days for cardiovascular and hemorrhagic complications. RESULTS Four hundred nineteen eligib…
Análisis tiempo-frecuencia de la fibrilación ventricular. Estudio experimental
2006
Introduction and objectives. The analysis of frequency variability during ventricular fibrillation has yielded inconsistent results. We used an experimental model of ventricular fibrillation, with a short timescale, to analyze variations in frequency and their associated spatial distribution. Methods. Epicardial recordings of ventricular fibrillation were made in 10 perfused isolated rabbit heart preparations using a multiple electrode system (i.e., 240 unipolar electrodes). Both spectral and time-frequency analysis were used to derive the dominant frequency in the anterolateral wall of the left ventricle. Results. Linear regression analysis showed that there was a good correlation between …
Influencia del tipo de registro (unipolar o bipolar) en las características espectrales de los registros epicárdicos de la fibrilación ventricular. E…
2007
Introduction and objectives. The aim of this study was to examine the hypothesis that the recording mode (ie, unipolar or bipolar) affects the information obtained using spectral analysis techniques during ventricular fibrillation by carrying out an experiment using epicardial electrodes. Methods. Recordings of ventricular fibrillation were obtained in 29 isolated rabbit hearts using a multipleelectrode probe located on the left ventricular free wall. The parameter values obtained in the frequency domain (by Fourier analysis) using unipolar or bipolar electrodes, different interelectrode distances, and different orientations (ie, horizontal, vertical, or diagonal) were compared. Results. Ch…
Ventilation/perfusion ratios measured by multiple inert gas elimination during experimental cardiopulmonary resuscitation
2014
Background During cardiopulmonary resuscitation (CPR) the ventilation/perfusion distribution (VA/Q) within the lung is difficult to assess. This experimental study examines the capability of multiple inert gas elimination (MIGET) to determine VA/Q under CPR conditions in a pig model. Methods Twenty-one anaesthetised pigs were randomised to three fractions of inspired oxygen (1.0, 0.7 or 0.21). VA/Q by micropore membrane inlet mass spectrometry-derived MIGET was determined at baseline and during CPR following induction of ventricular fibrillation. Haemodynamics, blood gases, ventilation distribution by electrical impedance tomography and return of spontaneous circulation were assessed. Inter…
Circulating Levels of Ferritin, RDW, PTLs as Predictive Biomarkers of Postoperative Atrial Fibrillation Risk after Cardiac Surgery in Extracorporeal …
2022
Postoperative atrial fibrillation (POAF) is the most common arrhythmia after cardiac surgery in conventional extracorporeal circulation (CECC), with an incidence of 15–50%. The POAF pathophysiology is not known, and no blood biomarkers exist. However, an association between increased ferritin levels and increased AF risk, has been demonstrated. Based on such evidence, here, we evaluated the effectiveness of ferritin and other haematological parameters as POAF risk biomarkers in patients subjected to cardiac surgery. We enrolled 105 patients (mean age = 70.1 ± 7.1 years; 70 men and 35 females) with diverse heart pathologies and who were subjected to cardiothoracic surgery. Their blood sample…
The role of patient specific morphology and contractility of the left atrial appendage on the thromboembolic risk in atrial fibrillation
2022
The vast majority of thrombi that cause ischemic complications in atrial fibrillation originate in the left atrial appendage. The left atrial appendage is an anatomical structure that starts from the left atrium, characterized by a wide morphological variability between individuals. This work analyses simulated hemodynamic for different patient-specific models of the left atrial appendage, using computational fluid-structure interaction studies, modelling the effect of changes in contractility and shape resulting from atrial fibrillation. Three operating conditions were analysed: sinus rhythm, acute atrial fibrillation, and chronic atrial fibrillation. These were simulated on four patient-s…
Photo-inhibition of Ab fibrillation mediated by a newly designed fluorinated oxadiazole
2015
Uncontrolled aggregation of amyloid beta peptide (A?) is the main cause of Alzheimer's Disease. Therapeutic approaches of intervention in amyloid diseases include the use of small molecules able to stabilize the soluble A? conformation, or to redirect the amyloidogenic pathway towards non-toxic and non-fibrillar states. Fluorometric measurements revealed that the 3-(4'-trifluoromethylphenyl)-5-(4'-methoxyphenyl)-1,2,4-oxadiazole, when irradiated, is able to interact with monomeric A? peptide readdressing the aggregation pathway toward the formation of amorphous aggregates as evidenced by means of CD, AFM, and SAXS measurements. We hypothesize that this compound, under radiation, forms a rea…
Cardiac changes in subclinical and overt hyperthyroid women: retrospective study
2003
This retrospective and descriptive 4-year study was undertaken to describe cardiac changes in subclinical and overt hyperthyroidism.We revised the charts of 386 consecutive cardiopathic women whose blood samples were referred to the Radioimmunoassay Laboratory to evaluate thyroid function from 1 January 1997 through 31 December 2000.After excluding women because euthyroid or hypothyroid, or taking amiodarone and women with hypertension, rheumatic disease, myocardial infarction, a total of 31 hyperthyroid women were thus selected for the study: 19 with subclinical hyperthyroidism and 12 with overt hyperthyroidism. The prevalence of atrial fibrillation did not differ between subclinical (48%)…
Implication du récepteur 5-HT4 cardiaque humain dans la fibrillation auriculaire : rôle d’auto-anticorps dirigés contre ce récepteur ?
2004
The human cardiac 5-HT4 receptor was cloned in 1997. It is functional only in atrial myocytes where it is positively coupled via Gs to the adenylate cyclase, activates the cAMP-dependent protein kinase (PKA) and in consequence phosphorylates a variety of intracellular proteins implicated in excitation-contraction coupling. A number of studies suggest a role for the 5-HT4 receptor in the maintenance or elongation of atrial fibrillation. It is now accepted that certain cardiac pathologies involve auto-immune processes. Antibodies directed against the second extracellular loop of a number of cardiac G-protein linked receptors have been found. The human cardiac 5-HT4 receptor could therefore al…
[Is ICD-programming for double intraoperative defibrillation threshold energy safe and effective during long-time follow-up? Results of a prospective…
1999
The aim of this prospective and randomized study was to evaluate the safety and efficacy of a reduced shock strength in transvenous implantable defibrillator therapy. So far clinical data concerning the safety margin of the shock energy in ICD therapy do not exist. The shock energy tested during long-term follow-up in this study was twice the intraoperatively measured defibrillation threshold (DFT). A total number of 176 consecutive patients representing a typical cohort of ICD patients were evaluated. All patients received a non-thoracotomy lead system (CPI, Endotak 0070, 0090) and a biphasic cardioverter-defibrillator with the ability to store episodes (Cardiac Pacemakers Inc., Ventac TM …