Search results for " Filters"

showing 10 items of 85 documents

Search for standard model Higgs bosons produced in association with W bosons.

2007

We report on the results of a search for standard model Higgs bosons produced in association with W bosons from p-pbar collisions at root s = 1.96 TeV. The search uses a data sample corresponding to approximately 1 fb-1 of integrated luminosity. Events consistent with the W to l-nu and H to b-bbar signature are selected by triggering on a high-pT electron or muon candidate and tagging one or two of the jet candidates as having originated from b quarks. A neural network filter rejects a fraction of tagged charm and light flavor jets, increasing the b-jet purity in the sample and thereby reducing the background to Higgs boson production. We observe no excess l-nu-b-bbar production beyond the …

Particle physicsFOS: Physical sciencesNeural network filtersGeneral Physics and AstronomyElementary particleddc:500.201 natural sciencesStandard ModelHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)13.85.Rm 14.80.BnJets0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Mass hypothesesSampling010306 general physicsBosonsBosonPhysicsProblem solvingMathematical models010308 nuclear & particles physicsBranching fractionPhysicsHigh Energy Physics::PhenomenologyCenter (category theory)Higgs BosonsHiggs bosonProduction (computer science)High Energy Physics::ExperimentNeural networksLeptonPhysical review letters
researchProduct

Surface investigation and aluminum oxide estimation on test filters for the ATHENA X-IFU and WFI detectors

2016

The ATHENA mission provides the demanded capabilities to address the ESA science theme "Hot and Energetic Universe". Two complementary instruments are foreseen: the X-IFU (X-ray Integral Field Unit) and WFI (Wide Field Imager). Both the instruments require filters to avoid that the IR radiation heats the X-IFU cryogenic detector and to protect the WFI detector from UV photons. Previous experience on XMM filters recommends to employ bilayer membrane consisting of aluminum deposited on polyimide. In this work, we use the X-ray Photoelectron Spectroscopy (XPS) to quantify the native aluminum oxide thickness that affects the spectral properties of the filter. The estimation of the oxide thickne…

PhotonMaterials sciencebusiness.industryPhotoemission spectroscopyInfraredAthena mission thermal filters aluminum oxide.thermal filtersDetector02 engineering and technologyRadiation021001 nanoscience & nanotechnology01 natural sciences7. Clean energy010309 opticsaluminum oxideOpticsSettore FIS/05 - Astronomia E AstrofisicaX-ray photoelectron spectroscopyFilter (video)0103 physical sciencesPrototype filter0210 nano-technologybusinessAthena mission
researchProduct

Calibration of the XRT-SOLARB flight filters at the XACT facility of INAF-OAPA

2004

The X-Ray Telescope (XRT) experiment on-board the Japanese satellite SOLAR-B (launch in 2006) aimed at providing full Sun field of view at ~ 1.5" angular resolution, will be equipped with two wheels of focal-plane filters to select spectral features of X-ray emission from the Solar corona, and a front-end filter to significantly reduce the visible light contamination. We present the results of the X-ray calibrations of the XRT flight filters performed at the X-ray Astronomy Calibration and Testing (XACT) facility of INAF-OAPA. We describe the instrumental set-up, the adopted measurement technique, and present the transmission vs. energy and position measurements.

PhysicsX-ray astronomybusiness.industryAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for AstrophysicsField of viewFilter (signal processing)law.inventionTelescopeOpticslawCalibrationAstrophysics::Solar and Stellar AstrophysicsAngular resolutionSatellitebusinessImage resolutionX-ray Astronomy Instrumentation Filters CalibrationRemote sensing
researchProduct

Thermal shielding of the SIMBOL-X mirror assembly

2007

The thermal modeling of the SIMBOL-X X-ray telescope has shown that thermal shielding of both the telescope ends is one possibility to ensure temperature uniformity of the mirror and to reduce the required heating power. The design of the thermal shielding must minimize the thermal exchange in a trade off between transparency of the shields to soft X-rays and mechanical robustness. We discuss two possible designs of the thermal shielding of the mirror module and show transmission curves at X-ray wavelengths.

PhysicsX-ray astronomybusiness.industryAstrophysics::High Energy Astrophysical PhenomenaShieldsX-ray telescopelaw.inventionTelescopeWavelengthOpticsTransmission (telecommunications)lawElectromagnetic shieldingThermalX-ray Astronomy Simbol-X X-ray filters Thermal shieldsbusinessSPIE Proceedings
researchProduct

Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters

2013

After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons lear…

Physicsbusiness.industryAtomic force microscopyDetectorX-ray detectorEPICOn boardSettore FIS/05 - Astronomia E AstrofisicaOpticsObservatoryX-rays: XMM-Newton X-rays: instrumentation X-rays: filtersCalibrationData analysisbusinessSPIE Proceedings
researchProduct

Wavelength-flattened directional couplers for mirror-symmetric interferometers

2005

In the context of guided optics, we derive, analytically and geometrically, a rigorous general criterion to design wavelength insensitive interferometers with mirror symmetry, which are needed for wavelength multiplexing/demultiplexing. The criterion is applied to a practical case, resulting in an interferometer that works on a band wider than 70 nm.

Physicsbusiness.industryFOS: Physical sciencesPhysics::OpticsContext (language use)Optical directional couplersMultiplexingAtomic and Molecular Physics and OpticsWavelengthInterferometryOptical waveguide filtersOpticsOptical interferometryWavelength division multiplexingAstronomical interferometerPower dividers and directional couplersGeometric modelingbusinessMirror symmetryOptical planar waveguide componentsPhysics - OpticsOptics (physics.optics)
researchProduct

The filter wheel and filters development for the X-IFU instruments onboard Athena

2016

Athena is the large mission selected by ESA in 2013 to investigate the science theme “Hot and Energetic Universe” and presently scheduled for launch in 2028. One of the two instruments located at the focus of the 12 m-long Athena telescope is the X-ray Integral Field Unit (X-IFU). This is an array of TES microcalorimeters that will be operated at temperatures of 50 mK in order to perform high resolution spectroscopy with an energy resolution down to 2.5 eV at energies < 7 keV. In order to cope with the large dynamical range of X-ray fluxes spanned by the celestial objects Athena will be observing, the X-IFU will be equipped with a filter wheel. This will allow the user to fine tune the i…

Physicsbusiness.industrymedia_common.quotation_subject01 natural sciencesUniverselaw.invention010309 opticsTelescopeOpticsSettore FIS/05 - Astronomia E AstrofisicalawRange (aeronautics)0103 physical sciencesCalibrationAthena X-rays Filter Wheel Filters radioactive calibration sourcesDevelopment (differential geometry)Focus (optics)business010303 astronomy & astrophysicsHost (network)Energy (signal processing)media_common
researchProduct

Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation II: analysis of in-flight data

2013

After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton we have reviewed the status of its thin and medium filters by performing both analysis of data collected in-flight and laboratory measurements on on-ground back-up filters. We have investigated the status of the EPIC thin and medium filters by performing an analysis of the optical loading in the PN offset maps to gauge variations in the optical and UV transmission of the filters. We both investigated repeated observations of single optically bright targets and performed a statistical analysis of the extent of loading versus visual magnitude at different epochs. We report the results of these …

Physicsgenetic structuresbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaX-Rays: XMM-Newton - X-rays: instrumentation - X-rays: filtersEPICXMM-Newton - X-rays: instrumentation - X-rays: filters [X-Rays]eye diseasesOn boardOpticsApparent magnitudeSettore FIS/05 - Astronomia E AstrofisicaTransmission (telecommunications)ObservatoryData analysisStatistical analysissense organsbusinessFlight data
researchProduct

Integration of local features into a global shape

2001

AbstractIt is a well-established fact that the cortical filters selective for spatial frequency and orientation have a limited spatial extent. The present study investigated how information from local filters is integrated into global shapes. Specifically, we were interested in whether identification of a global pattern consisting of small oriented, spatially-bandpass features (Gabor patches) depends on the orientations of those features. The observer was presented with a C-like stimulus shape comprised of oriented Gabor elements on a blank background, and the performance measure was the threshold contrast for identifying the global orientation of the C-shape (four possible rotated orientat…

PsychometricsComputer sciencemedia_common.quotation_subjectCortical filtersPattern perceptionBlankContrast SensitivityOrientationPerceptionHumansVisual Pathwaysmedia_commonAnalysis of VarianceCommunicationbusiness.industryPattern recognitionSpace perceptionLong-range perceptual interactionsSensory SystemsOphthalmologyPattern Recognition VisualArtificial intelligenceSpatial frequencySpatial extentbusinessAlgorithmsInformation integrationVision Research
researchProduct

A comparison of micropore membrane inlet mass spectrometry–derived pulmonary shunt measurement with riley shunt in a porcine model

2009

The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model. However, agreement with a frequently used and accepted method for quantifying deficits in arterial oxygenation has not been established. We compared MMIMS-derived shunt (M-S) as a fraction of total cardiac output (CO) with Riley shunt (R-S) derived from the R-S formula in a porcine lung injury model.To allow a …

Pulmonary AtelectasisPulmonary CirculationSwineCapillary actionBlood PressureMass spectrometryVentilation/perfusion ratioMass SpectrometryAdministration InhalationVentilation-Perfusion RatiomedicineAnimalsCardiac OutputChromatographyMultiple inert gas elimination techniquebusiness.industryMicropore FiltersModels CardiovascularMembranes ArtificialLung InjuryBlood flowrespiratory systemOxygenDisease Models AnimalAnesthesiology and Pain MedicineAnesthesiaAnesthetics InhalationLinear ModelsPulmonary shuntGas chromatographyBlood Gas Analysismedicine.symptombusinessShunt (electrical)
researchProduct