Search results for " Fixed"

showing 10 items of 248 documents

On dependence of sets of functions on the mean value of their elements

2009

The paper considers, for a given closed bounded set M ⊂ R m and K = (0,1) n ⊂ R n , the set M = {h ϵ L2 (K;R m ) | h(x) ϵ M a.e.x ϵ K} and its subsets It is shown that, if a sequence {hk } ⊂ coM converges to an element hk ϵ M(hk ) there is h‘k ϵ M(ho ) such that h'k - hk → 0 as k → ∞ . If, in addition, the set M is finite or M is the convex hull of a finite set of elements, then the multivalued mapping h → M(h) is lower semicontinuous on coM. First published online: 14 Oct 2010

Convex hullDiscrete mathematicsSequenceBounded setMean valuemultivalued mappingsubsets of functions with fixed mean valueModeling and Simulationcontinuous dependenceQA1-939Element (category theory)Finite setAnalysisMathematicsMathematicsMathematical Modelling and Analysis
researchProduct

The effect of the solids and hydraulic retention time on moving bed membrane bioreactor performance

2018

Abstract The aim of the present paper was to investigate the effect of solids (SRT) and hydraulic (HRT) retention time on Integrated Fixed Film Activated Sludge (IFAS) University of Cape Town (UCT) membrane Bioreactor (MBR). In particular, three different pairs of SRT and HRT values were analysed, namely, Phase I 56 d/30 h, Phase II 31 d/15 h and Phase III 7 d/13 h. The short-term effect of these three SRT/HRT conditions was assessed by analysing several system performance indicators: organic carbon and biological nutrient (nitrogen and phosphorus) removal, biomass respiratory activity, activated sludge filtration properties and membrane fouling. The results showed that the decrease of SRT/…

DenitrificationHydraulic retention timeIntegrated fixed film activated sludgeStrategy and Management0208 environmental biotechnology02 engineering and technology010501 environmental sciencesMembrane bioreactor01 natural sciencesIndustrial and Manufacturing EngineeringBiological phosphorus removal0105 earth and related environmental sciencesGeneral Environmental ScienceChromatography2300Settore ICAR/03 - Ingegneria Sanitaria-AmbientaleRenewable Energy Sustainability and the EnvironmentChemistryMembrane foulingBuilding and ConstructionNitrogen removalPulp and paper industryMembrane BioReactor020801 environmental engineeringStrategy and Management1409 Tourism Leisure and Hospitality ManagementEnhanced biological phosphorus removalActivated sludgeVolatile suspended solidsNitrificationSolid retention timehuman activitiesHydraulic retention timeJournal of Cleaner Production
researchProduct

A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.

2014

Abstract Statement of problem Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Purpose The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Material and methods Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Resu…

Dental Restoration FailureAdultMaleSurface Propertiesmedicine.medical_treatmentDentistryDental CariesProsthesisProspective evaluationAnterior regionDental MaterialsRecurrencemedicineHumansDental Restoration FailureProspective StudiesProspective cohort studyDenture DesignSurvival rateAgedbusiness.industryPeriapical DiseasesMiddle AgedDental PorcelainDenture RetentionSurvival AnalysisDental VeneersTreatment OutcomeComputer-Aided DesignDenture Partial FixedVeneerFemaleZirconiumOral SurgerybusinessComplicationFollow-Up StudiesThe Journal of prosthetic dentistry
researchProduct

Survival rates of a lithium disilicate-based core ceramic for three-unit esthetic fixed partial dentures: a 10-year prospective study.

2013

Purpose The aim of this prospective study was to evaluate the clinical efficacy and long-term survival rate of three-unit fixed partial dentures (FPDs) made from lithium disilicate-based core ceramic. Materials and methods Twenty-one three-unit FPDs were placed in 19 patients to replace single lost teeth in the esthetic area, following a study protocol that took clinical, esthetic, and radiologic aspects into consideration. Each case was reviewed at 1 week following placement, at 6 months, and then annually for 10 years. Statistical analysis was performed using Kaplan-Meier survival analysis. Results Out of the 19 patients, 14.3% presented reversible postoperative sensitivity. Recession was…

Dental Restoration FailureMaleCeramicsSurface PropertiesDentistryColorDental AbutmentsDental bondingDental CariesEsthetics DentalDental AbutmentsOcclusionMedicineHumansGingival RecessionDental Restoration FailureLongitudinal StudiesProspective StudiesProspective cohort studyDenture DesignSurvival rateSurvival analysisbusiness.industryDental Plaque IndexDental BondingGeneral MedicineDentin SensitivityMiddle AgedTooth Preparation ProsthodonticDental PorcelainSurvival AnalysisDental Plaque IndexTreatment OutcomeLithium CompoundsDenture Partial FixedFemaleOral SurgeryPeriodontal IndexbusinessFollow-Up StudiesThe International journal of prosthodontics
researchProduct

Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses

2017

The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5-55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student's t test, paired t-test and Weibull statistics (α=0.05). No diffe…

Dental Stress AnalysisMaterials scienceGlass ionomer cementDentistryDental Abutments02 engineering and technologyBendingVeneering ceramicDental Materials03 medical and health sciences0302 clinical medicineMaterials TestingCubic zirconiaDental Restoration FailureGeneral Dentistrybusiness.industryFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyDental VeneersGlass Ionomer CementsCeramics and CompositesFracture (geology)Computer-Aided DesignDenture Partial FixedZirconium0210 nano-technologybusinessDental Materials Journal
researchProduct

Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal‐Ceramic, Monolithic and Veneered Zirconia Posterior Fixed Partial Dent…

2018

PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the…

Dental Stress AnalysisMaterials scienceMetal Ceramic AlloysDental Abutments02 engineering and technologyCrossheadDental MaterialsRandom Allocation03 medical and health sciences0302 clinical medicineMaterials TestingFixed partial denturesCubic zirconiaDental Restoration FailureComposite materialGeneral DentistryUniversal testing machineFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyMetal ceramicDental VeneersFracture (geology)Computer-Aided DesignDenture Partial FixedStress MechanicalZirconium0210 nano-technologyJournal of Prosthodontics
researchProduct

Dental water jet efficacy in the plaque control of orthodontic patients wearing fixed appliance: A randomized controlled trial.

2018

Background Different studies assess the role of fixed orthodontic appliances in supragingival plaque accumulation. In patients wearing fixed orthodontic appliances a good management of oral hygiene is required in order to prevent complication like as decay, enamel demineralization, gingivitis, gingival hyperplasia and periodontitis. The aim of this Randomized Controlled Trial (RCT) is to evaluate the efficacy of the use of a DWJ in patients under orthodontic treatment with fixed multibracket appliance. Material and methods The study design was single-blinded RCT with a split mouth protocol. Each patient followed a personal cleaning protocol using a DWJ in addition to traditional brushing on…

Dental water jet; Fixed orthodontics; Gingival index; Plaque indexPlaque indexDentistryOrthodonticsPlaque controlOral hygienelaw.invention03 medical and health sciencesGingivitisGingival index0302 clinical medicineRandomized controlled triallawmedicineIn patient030212 general & internal medicineGeneral DentistryPeriodontitisbusiness.industryDental water jetResearchWater jet030206 dentistrymedicine.disease:CIENCIAS MÉDICAS [UNESCO]Fixed orthodonticsUNESCO::CIENCIAS MÉDICASPlaque indexmedicine.symptombusinessJournal of clinical and experimental dentistry
researchProduct

Monitoring Results and Energy Performances Evaluation of Freescoo Solar DEC Systems

2016

Abstract This work addresses the energy saving performances of some solar Desiccant and Evaporative Cooling (DEC) systems working with the freescoo technology. The innovative freescoo concept is based on the use two fixed and cooled adsorption beds and advanced indirect evaporative cooling processes. The main feature of this new adsorption bed concept is to allow the simultaneous dehumidification and cooling of air. The systems analyzed have been installed in Italy last here and results based on field monitoring data are here presented. A description of the monitored systems and comparisons between the energy performances based on the main performance indicators such as EER, thermal COP, co…

DesiccantPVTEngineeringWork (thermodynamics)Settore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industry020209 energyfreescoo Solar DEC Adsorption fixed and cooled bed PVTfreescooAdsorption fixed and cooled bed02 engineering and technologyGridEnergy(all)freescoo; Solar DEC; Adsorption fixed and cooled bed; PVT ;Thermal0202 electrical engineering electronic engineering information engineeringSolar DECPerformance indicatorElectricitybusinessProcess engineeringPVT ;SimulationEnergy (signal processing)Evaporative coolerEnergy Procedia
researchProduct

Second Generation of Freescoo Solar DEC Prototypes for Residential Applications

2015

Freescoo is an innovative all-in-one compact solar Desiccant Evaporative Cooling (DEC) air conditioner concept. Results of the first prototype developed were presented at SHC Conference last year. Now a second generation of freescoo prototypes for applications in residential and small office buildings have been installed in Italy at ENEA Casaccia and at UNIPA. The thermodynamic cycle is based on the use of fixed and cooled adsorption beds and advanced evaporative cooling concepts. The adsorption bed, which is a fin and tube heat exchanger packed with silica gel grains, allows simultaneous dehumidification and cooling of the process air. The indirect evaporative cooling process, operated dow…

Desiccantfreescoo compact Solar DEC Adsorption fixed and cooled bed stand-alone operationEngineeringSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industryWet-bulb temperatureNuclear engineeringElectrical engineeringPlate heat exchangerstand-alone operationfreescooAdsorption fixed and cooled bedtand-alone operationstand-alone operation ;Energy(all)Air conditioningThermodynamic cycleThermalHeat exchangercompact Solar DECAdsorption fixed and cooled bed;freescoo;compact Solar DEC;stand-alone operationbusinessEvaporative coolerEnergy Procedia
researchProduct

Approximate fixed points of set-valued mapping in b-metric space

2016

We establish existence results related to approximate fixed point property of special types of set-valued contraction mappings, in the setting of b-metric spaces. As consequences of the main theorem, we give some fixed point results which generalize and extend various fixed point theorems in the existing literature. A simple example illustrates the new theory. Finally, we apply our results to establishing the existence of solution for some differential and integral problems.

Discrete mathematicsAlgebra and Number Theory010102 general mathematicsb-metric space η-contraction fixed point theorem integral inclusionFixed point01 natural sciences010101 applied mathematicsSet (abstract data type)Metric spaceSettore MAT/05 - Analisi MatematicaSettore MAT/03 - Geometria0101 mathematicsComposite materialAnalysisMathematics
researchProduct