Search results for " Flow velocity"

showing 10 items of 149 documents

Pre- and intraoperative methods of controlling cerebral circulation in giant aneurysm surgery.

1995

The surgical treatment of giant aneurysms usually requires temporary clipping of the aneurysmatic vessel. In planning the surgical approach and in applying temporary clips, the surgeon must consider collateral circulations. The functional integrity of the collateral vessels frequently decides the patient's outcome. In 8 patients with internal carotid artery giant aneurysm, measurements of blood flow velocities in the ipsilateral middle cerebral artery were performed preoperatively with transcranial Doppler ultrasound (TCD) during manual occlusion of the carotid artery at the neck. Three different perfusion patterns were established, and each collateral capacity was rated as insufficient, te…

AdultCarotid Artery DiseasesMalemedicine.medical_specialtyUltrasonography Doppler TranscranialCollateral CirculationBasal GangliaBrain IschemiaCerebral circulationAneurysmmedicine.arteryMonitoring IntraoperativeOcclusionMedicineHumansDominance CerebralAgedCerebral Cortexbusiness.industryBrainIntracranial AneurysmGeneral MedicineBlood flowMiddle AgedCollateral circulationmedicine.diseaseTranscranial DopplerSurgeryRegional Blood FlowMiddle cerebral arterycardiovascular systemSurgeryFemaleNeurology (clinical)RadiologyInternal carotid arterybusinessBlood Flow VelocityCarotid Artery InternalNeurosurgical review
researchProduct

Cerebral blood flow, computerized tomography and angiography in 562 cases of cerebrovascular insufficiency

1987

The measurement of cerebral blood flow (CBF) in addition to cerebral computerized tomography (CT) and angiography is most reliable in cases of transient ischemic attacks (TIA) and prolonged reversible ischemic neurologic deficits (PRIND). Alterations of CBF can be detected in symptom-free intervals. The cerebrovascular reactivity to CO2 stimulus is regarded as an especially suitable tool to prove the cerebrovascular reserve. If it is diminished, cerebral angiography should be carried out since it will often show major obstructive lesions. Angiography shows no sure correlation between CBF and collateral circulation. Strong opthalmic pathways in unilateral occlusion of the internal carotid ar…

AdultCarotid Artery Diseasesmedicine.medical_specialtyAdolescentBrain Ischemiamedicine.arteryOcclusionmedicineHumansChildAgedAged 80 and overmedicine.diagnostic_testCerebral infarctionbusiness.industryCerebral InfarctionGeneral MedicineCarbon DioxideMiddle AgedIntracranial ArteriosclerosisCollateral circulationmedicine.diseaseCerebral AngiographyCerebral blood flowIschemic Attack TransientCerebrovascular CirculationMiddle cerebral arteryAngiographycardiovascular systemSurgeryNeurology (clinical)RadiologyInternal carotid arteryTomography X-Ray ComputedbusinessBlood Flow VelocityCarotid Artery InternalCerebral angiographyNeurosurgical Review
researchProduct

Chronic Thromboembolic Pulmonary Hypertension: Pre- and Postoperative Assessment with Breath-hold MR Imaging Techniques

2004

To evaluate the potential of breath-hold magnetic resonance (MR) imaging techniques in morphologic and functional assessment of patients with chronic thromboembolic pulmonary hypertension (CTEPH) before and after surgery.Thirty-four patients with CTEPH were examined before and after pulmonary thromboendarterectomy (PTE). For morphologic assessment, contrast material-enhanced MR angiography was used; for assessment of hemodynamics, velocity-encoded gradient-echo sequences and cine gradient-echo sequences along the short axis of the heart were performed. Contrast-enhanced MR angiography was compared with selective digital subtraction angiography (DSA) for depiction of central thromboembolic m…

AdultGadolinium DTPAMalemedicine.medical_specialtyHypertension Pulmonarymedicine.medical_treatmentContrast MediaMagnetic Resonance Imaging CineEndarterectomyPulmonary ArterySensitivity and SpecificityVentricular Function LeftMagnetic resonance angiographyPostoperative ComplicationsHeart SeptumImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesAgedThrombectomyEndarterectomymedicine.diagnostic_testPulmonary thromboendarterectomybusiness.industryHemodynamicsAngiography Digital SubtractionMagnetic resonance imagingDigital subtraction angiographyMiddle AgedImage Enhancementmedicine.diseaseMagnetic Resonance ImagingPulmonary hypertensionmedicine.anatomical_structureChronic DiseaseAngiographyVentricular Function RightFemaleRadiologyPulmonary EmbolismbusinessBlood Flow VelocityMagnetic Resonance AngiographyFollow-Up StudiesArteryRadiology
researchProduct

Magnetically labeled water perfusion imaging of the uterine arteries and of normal and malignant cervical tissue: initial experiences.

1998

Purpose: The aim of this pilot study was to evaluate a magnetically labeled water perfusion imaging technique as a non-contrast-enhanced approach to demonstrate the uterine artery, its branches, and to assess the cervical uterine blood flow in healthy volunteers and in patients with advanced uterine cervical carcinoma (FIGO IIB-IVA). Methods and Materials: Seven healthy volunteers (mean age, 29 years) and twenty-two patients (mean age, 52 years) with advanced cancer of the uterine cervix (FIGO IIB-IVA) were prospectively examined by magnetically labeled water perfusion imaging at different inversion delay times (300–900 ms). The magnetic resonance imaging (MRI) findings of all patients were…

AdultGadolinium DTPAPathologymedicine.medical_specialtyBiomedical EngineeringBiophysicsHemodynamicsContrast MediaUterine Cervical NeoplasmsPerfusion scanningCervix UteriSensitivity and Specificitymedicine.arterymedicineHumansRadiology Nuclear Medicine and imagingUterine arteryCervixAgedNeoplasm Stagingmedicine.diagnostic_testNeovascularization Pathologicbusiness.industryUterusHemodynamicsWaterMagnetic resonance imagingBlood flowArteriesMiddle AgedImage EnhancementMagnetic Resonance ImagingPerfusionmedicine.anatomical_structureDynamic contrast-enhanced MRIFemaleNuclear medicinebusinessPerfusionBlood Flow VelocityMagnetic resonance imaging
researchProduct

Optical noninvasive monitoring of skin blood pulsations

2005

Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrh…

AdultMaleAdolescentHeartbeatMaterials Science (miscellaneous)Pulsatile flowArterial Occlusive DiseasesBlood volumeSensitivity and SpecificityIndustrial and Manufacturing EngineeringOpticsData acquisitionArterial occlusionsHeart RatePhotoplethysmogrammedicineAnimalsHumansDiagnosis Computer-AssistedBusiness and International ManagementPhotoplethysmographySkinFrequency filteringbusiness.industryReproducibility of ResultsEquipment DesignEquipment Failure Analysismedicine.anatomical_structurePulsatile FlowVascular resistanceFemalesense organsbusinessAlgorithmsBlood Flow VelocityBiomedical engineeringApplied Optics
researchProduct

Correlation of cerebral blood flow and MCA flow velocity measured in healthy volunteers during acetazolamide and CO2 stimulation

1995

Abstract The assessment of the cerebrovascular reserve capacity (RC) has become a widely used tool in the management of cerebrovascular disease. Discrepancies become obvious, however, if results obtained with different methods are compared. Aim of the present study, therefore, was to compare blood velocity and cerebral perfusion data in the same group of healthy test persons. In 32 volunteers regional cerebral blood flow (rCBF) was measured with the 133 Xe-inhalation method. F1 as grey matter flow and the initial slope index (ISI) were computed. Simultaneously flow velocity in the middle cerebral artery (V MCA ) was assessed by transcranial Doppler sonography (TCD). Measurements were perfor…

AdultMaleAdolescentHemodynamicsReference Valuesmedicine.arterymedicineHumansCerebral perfusion pressureAgedResting state fMRIbusiness.industryCarbon DioxideCerebral ArteriesMiddle AgedStimulation ChemicalAcetazolamideNeurologyCerebral blood flowCerebrovascular CirculationAnesthesiaMiddle cerebral arteryFemaleNeurology (clinical)medicine.symptomAcetazolamidebusinessHypercapniaPerfusionBlood Flow Velocitymedicine.drugJournal of the Neurological Sciences
researchProduct

Cerebral blood flow velocities after subarachnoid haemorrhage in relation to the amount of blood clots in the initial computed tomography.

1998

In 72 patients with acute subarachnoid haemorrhage (SAH) the relationship between the amount of subarachnoid blood clots detected by initial cranial computed tomography (CCT) up to 48 hours after bleeding and the later development of vasospasm, established by blood flow velocity measurement with transcranial Doppler ultrasound (TCD) was investigated. The serial Doppler examinations started within the first 72 hours after SAH and were carried out every second day up to three weeks. Each Doppler recording was accompanied by a neurological examination. Patients classified as Hunt and Hess grade V were excluded from the study. All patients with remarkable brain oedema in CCT or with intracrania…

AdultMaleAdolescentUltrasonography Doppler TranscranialHemodynamicsmedicineHumanscardiovascular diseasesIntracranial pressureAgedVascular diseasebusiness.industryVasospasmBlood flowLaser Doppler velocimetryIntracranial Embolism and ThrombosisMiddle AgedSubarachnoid Hemorrhagemedicine.diseasenervous system diseasesTranscranial DopplerCerebral blood flowIschemic Attack TransientAnesthesiaCerebrovascular Circulationcardiovascular systemSurgeryFemaleNeurology (clinical)Nuclear medicinebusinessTomography X-Ray ComputedBlood Flow Velocitycirculatory and respiratory physiologyActa neurochirurgica
researchProduct

Volume flow in the common carotid artery does not decrease postprandially.

2003

Background and Purpose. A commonplace explanation for postprandial fatigue is the assumption of the redistribution of perfusion from the cerebral to the mesenterial territory. However, this assumption has never been scientifically proven. Methods. Because approximately 70% of the blood flow in the common carotid artery (CCA) is directed to the internal carotid artery, this vessel can be seen as a major brain-supplying artery. Flow volume in the CCA can be measured by color M-mode duplex sonography. The authors investigated the flow volume rate in 20 healthy volunteers before and after the intake of a high-energy meal. Heart rate, blood pressure, and expiratory CO2 were also measured at both…

AdultMaleCarotid Artery Commonmedicine.arteryHeart ratemedicineHumansRadiology Nuclear Medicine and imagingCommon carotid arteryFatigueUltrasonography Doppler Duplexbusiness.industryBrainBlood flowPostprandial PeriodBlood pressurePostprandialmedicine.anatomical_structureAnesthesiaFemaleNeurology (clinical)Internal carotid arterybusinessPerfusionBlood Flow VelocityArteryJournal of neuroimaging : official journal of the American Society of Neuroimaging
researchProduct

Transitional hemodynamics in infants of diabetic mothers by targeted neonatal echocardiography, electrocardiography and peripheral flow study

2017

Objective: Metabolic alterations of intrauterine environment in diabetes mellitus (DM) lead to fetal cardiac dysfunctions that can persist after birth. The aim of the study was to assess the cardiovascular adaptation in infants born to diabetic mothers (IDM) with different degrees of glycometabolic control, in relation to revised guidelines for diagnosis of DM and quality improvements in neonatal care. Materials and methods: An observational case-control study was conducted on IDM with gestational, type 1 and type 2 DM. Relevant maternal and neonatal anamnestic, clinical and laboratory data were analyzed. Electrocardiographic and echocardiographic analyses, including structural and systo-…

AdultMaleDoppler-echocardiographyPediatricsmedicine.medical_specialtycerebrovascular circulation; Doppler-echocardiography; glucose metabolism disorders; heart function; Observational case-control study; Pediatrics Perinatology and Child Health; Obstetrics and GynecologyHemodynamics030204 cardiovascular system & hematologyDoppler echocardiographyElectrocardiography03 medical and health sciencesheart function0302 clinical medicineObstetrics and gynaecologyPregnancyglucose metabolism disorderDiabetes mellitusmedicineHumansObservational case-control studyFetus030219 obstetrics & reproductive medicinemedicine.diagnostic_testbusiness.industryfungiInfant Newbornfood and beveragesObstetrics and GynecologyHeartmedicine.diseaseCerebrovascular CirculationPeripheralDiabetes GestationalEchocardiographyCase-Control StudiesPediatrics Perinatology and Child Healthcardiovascular systemFemalecerebrovascular circulationbusinessElectrocardiographyBlood Flow Velocity
researchProduct

Transcranial Doppler ultrasound study of the effects of nitrous oxide on cerebral autoregulation during neurosurgical anesthesia: a randomized contro…

2003

Object. Nitrous oxide has an adverse effect on cerebrovascular hemodynamics. Increased intracranial pressure, cerebral blood flow (CBF), cerebral metabolic rate of O2 (CMRO2), and reduced autoregulation indices have been reported, but their magnitudes are still being debated. This study was designed to evaluate the effect of N2O on CBF and autoregulatory indexes during N2O—sevoflurane anesthesia in a prospective randomized controlled series of patients. Methods. Two groups of 20 patients were studied on the basis of the use of N2O in the anesthetic gas mixture. The transient hyperemic response test, which relies on transcranial Doppler ultrasound techniques, was used to assess cerebral hemo…

AdultMaleDuplex ultrasonographyAdolescentUltrasonography Doppler TranscranialNitrous OxideHemodynamicsTranscranial Doppler cerebral autoregulation neurosurgical patientsAnesthesia GeneralCerebral autoregulationNeurosurgical ProceduresmedicineHomeostasisHumansAutoregulationIntracranial pressurebusiness.industrySettore MED/27 - NeurochirurgiaBrainMiddle AgedEchoencephalographyTranscranial DopplerCerebral blood flowAnesthesiaAnestheticFemalebusinessBlood Flow Velocitymedicine.drugJournal of neurosurgery
researchProduct