Search results for " Fluorescence"

showing 10 items of 1097 documents

Passive direct measurement of sun-induced chlorophyll fluorescence spectrum from in vivo leaves

2022

The fluorescence of chlorophyll in vegetation is a weak signal emitted between 650 and 850 nm that is mixed with the much more intense light reflected by the leaf, which is why active methods are commonly used (through the additional contribution of controlled artificial light) or using indirect measurements instead. So, the measurement is provided just in relative units in the first case, or the accuracy of the estimate in the second case is uncertain without proper direct validation. The Thesis presents a new device, called FluoWat, for passive measurement that allows direct measurement of the fluorescence emission of leaves in vivo under natural conditions in the field with sunlight. And…

:FÍSICA::Óptica ::Espectroscopía [UNESCO]optical propertiesspectroscopy:FÍSICA::Óptica ::Radiometría [UNESCO]chlorophyll fluorescence:CIENCIAS DE LA VIDA::Biofísica::Bioóptica [UNESCO]in vivo leafUNESCO::CIENCIAS DE LA VIDA::Biofísica::BioópticaUNESCO::FÍSICA::Óptica ::EspectroscopíaUNESCO::CIENCIAS DE LA VIDA::Biología vegetal (Botánica) ::Otras:CIENCIAS DE LA VIDA::Biología vegetal (Botánica) ::Otras [UNESCO]UNESCO::FÍSICA::Óptica ::Propiedades ópticas de los sólidosUNESCO::FÍSICA::Óptica ::Radiometría:FÍSICA::Óptica ::Propiedades ópticas de los sólidos [UNESCO]sun light
researchProduct

Intestinal absorption pathway of gamma-aminobutyric acid in rat small intestine.

1994

Intestinal absorption of gamma-aminobutyric acid (GABA), as a model compound for gamma-aminoacids, has not been extensively studied from the kinetic viewpoint. Since data from our laboratory suggested that some competition arises between intestinal absorption of beta-alanine and GABA and since our intent was to maintain the aqueous stagnant diffusion layer in order to approach absorption tests to in vivo physiological conditions, a rat jejunum in situ study was undertaken in order to gain an insight into the mechanism of GABA absorption. In the present paper, results from assays using isotonic perfusion solutions with starting GABA concentrations ranging from 1 to 50 mM are reported. They s…

Absorption (pharmacology)MalePharmaceutical ScienceMichaelis–Menten kineticsAminobutyric acidIntestinal absorptionDiffusionNon-competitive inhibitionBody WaterIn vivoIntestine SmallmedicineAnimalsPharmacology (medical)Rats WistarChromatography High Pressure Liquidgamma-Aminobutyric AcidPharmacologyAlanineChemistryGeneral MedicineMembrane transportSmall intestineRatsmedicine.anatomical_structureSpectrometry FluorescenceBiochemistryIntestinal AbsorptionBiophysicsBiopharmaceuticsdrug disposition
researchProduct

OH-related Infrared Absorption Bands in Oxide Glasses

2005

We report the infrared activity, in the spectral region of the OH stretching modes, of different composite silicate glasses whose chemical composition is established by X-ray fluorescence measurements. The analysis of the absorption line profiles is made in terms of different spectral contributions, Gaussian in shape. The comparison with analogous spectra obtained in vitreous silica samples with impurity concentrations < 100 part per million moles is evidence of the effects of the different oxides on the vibrational properties of the OH groups. In particular, for oxide glasses a red shift of the composite band at about 3670 cm(-1), assigned to the OH stretching modes of free Si-OH groups an…

Absorption spectroscopyInfraredFTIR AbsorptionOxide glasseOxideAnalytical chemistryX-ray fluorescenceInfrared spectroscopyCondensed Matter PhysicsCondensed Matter::Disordered Systems and Neural NetworksSylanol groupsSilicateSpectral lineSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Settore FIS/03 - Fisica Della MateriaElectronic Optical and Magnetic Materialschemistry.chemical_compoundchemistryImpurityHydroxyl groupFTIR spectroscopy.Materials ChemistryCeramics and Compositessilicate glasse
researchProduct

On the Low-Lying Excited States ofsym-Triazine-Based Herbicides

2005

We report a joint computational and luminescence study on the low-lying excited states of sym-triazines, namely, 1,3,5-triazine (1) and the ubiquitous herbicides atrazine [6-chloro-N2-ethyl-N4-isopropyl-1,3,5-triazine-2,4-diamine (2)] and ametryn [6-methylthio-N2-ethyl-N4-isopropyl-1,3,5-triazine-2,4-diamine (3)]. Geometrical structures, energetics, and transition and state properties of I and 2 were computed at the TD-DFT, CASSCF, and CASPT2 levels of theory. The fluorescence and phosphorescence emission spectra, lifetimes, and fluorescence quantum yields were measured for the three compounds, and from these, the energies of the lowest excited states and their corresponding radiative rates…

Absorption spectroscopyQuantum yieldPhotochemistryMolecular physicsAbsorptionAb initio quantum chemistry methodsOscillometryPressureRadiative transferEmission spectrumPhysical and Theoretical ChemistryMolecular StructureChemistry PhysicalHerbicidesTriazinesChemistryTemperatureHydrogen-Ion ConcentrationModels TheoreticalAtomic and Molecular Physics and OpticsSpectrometry FluorescenceModels ChemicalSpectrophotometryExcited stateAtrazineIndicators and ReagentsPhosphorescenceLuminescenceSoftwareChemPhysChem
researchProduct

Effectiveness of microwave based digestion procedures for the demineralization of human milk and infant formulas prior to fluorometric determination …

1996

The use of two types of microwave oven, one domestic (A) and the other specially designed for laboratory (B) for microwave-based digestion, to destroy the organic matter in milk and infant formulas prior to fluorometric determination of selenium is studied in order to check their applicability and reliability. In both systems the best results were obtained using the acid mixture HNO3—H2O2, and additional treatment with perchloric acid (60%) in a Thermoblock. The application of two different microwave-based digestion procedures to infant formulas was free of interferences. In the case of human milk, it was necessary to use the standard addition method. Values obtained for detection and quant…

Accuracy and precisionMineralsChromatographyMilk HumanMicrowave ovenAnalytical chemistryFluorescence spectrometryInfant Newbornchemistry.chemical_elementInfantDemineralizationSeleniumDigestion (alchemy)Spectrometry FluorescencechemistryInfant formulaStandard additionHumansFemaleIndicators and ReagentsInfant FoodMicrowavesSeleniumFood Science
researchProduct

Sample Preparation Improvement in Polycyclic Aromatic Hydrocarbons Determination in Olive Oils by Gel Permeation Chromatography and Liquid Chromatogr…

2005

Abstract The determination of 15 polycyclic aromatic hydrocarbons (PAHs) in olive oil samples has been improved in order to obtain a fast methodology with a low limit of detection through the combination of liquid–liquid extraction with acetonitrile and preparative gel permeation chromatography (GPC) prior to the injection of purified extracts into a C18 column. Acetonitrile–water was used as the mobile phase with a gradient from 50 to 95%, w/w, acetonitrile in 30 min. The oven temperature was maintained at 15°C, and fluorometric detection was made at a fixed excitation wavelength of 264 nm and variable, optimal emission wavelength for each analyte ranging from 352 nm for 11-H-benzo(b)fluor…

AcetonitrilesTime FactorsFluoreneChemistry Techniques AnalyticalAnalytical ChemistryGel permeation chromatographychemistry.chemical_compoundPlant OilsEnvironmental ChemistryFluorometryUltrasonicsSample preparationPolycyclic Aromatic HydrocarbonsOlive OilChromatography High Pressure LiquidPharmacologychemistry.chemical_classificationDetection limitFluorantheneFluorenesMethylene ChlorideChromatographyChemistryExtraction (chemistry)TemperatureSilicon DioxideSpectrometry FluorescenceHydrocarbonChromatography GelPyreneAgronomy and Crop ScienceChromatography LiquidFood ScienceJournal of AOAC INTERNATIONAL
researchProduct

A fluorescence spectroscopy study of the interaction of monocationic quinine with phospholipid vesicles Effect of the ionic strength and lipid compos…

1997

Abstract The interaction of monocationic quinine with zwitterionic dimyristoyl phosphatidylcholine (DMPC) and mixed negatively-charged dimyristoylphosphatidyl glycerol (DMPG) DMPC small unilamellar vesicles in the liquid-crystalline phase was investigated by steady-state fluorescence spectroscopy at pH 7 and 37°C. The maximum fluorescence emission peak at 383 nm, upon excitation at 335 nm, shifts to lower wavelength and decreases its intensity as the ratio between the total lipid and quinine concentrations increases. This indicates that in the membrane-bound state quinine is in an environment of low polarity, more deeply buried when anionic DMPG is present in the vesicle. For monoprotonated…

Activity coefficientChemistryVesicleLipid BilayersOsmolar Concentrationtechnology industry and agricultureAnalytical chemistryPhosphatidylglycerolsFluorescenceAtomic and Molecular Physics and OpticsFluorescence spectroscopyAnalytical Chemistrychemistry.chemical_compoundSpectrometry FluorescenceMembraneIonic strengthPhase (matter)PhosphatidylcholineBenzoquinoneslipids (amino acids peptides and proteins)DimyristoylphosphatidylcholineInstrumentationPhospholipidsSpectroscopySpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
researchProduct

Binding of basic amphipathic peptides to neutral phospholipid membranes: a thermodynamic study applied to dansyl-labeled melittin and substance P ana…

1997

A thermodynamic approach is proposed to quantitatively analyze the binding isotherms of peptides to model membranes as a function of one adjustable parameter, the actual peptide charge in solution z(p)+. The main features of this approach are a theoretical expression for the partition coefficient calculated from the molar free energies of the peptide in the aqueous and lipid phases, an equation proposed by S. Stankowski [(1991) Biophysical Journal, Vol. 60, p. 341] to evaluate the activity coefficient of the peptide in the lipid phase, and the Debye-Huckel equation that quantifies the activity coefficient of the peptide in the aqueous phase. To assess the validity of this approach we have s…

Activity coefficientProtein ConformationLipid BilayersMolecular Sequence DataBiophysicsPhospholipidPeptideSubstance PBiochemistryMelittinBiomaterialschemistry.chemical_compoundElectrochemistryOrganic chemistryAmino Acid Sequencechemistry.chemical_classificationDansyl CompoundsAqueous solutionTransglutaminasesChemistryOrganic ChemistryGeneral MedicineMelittenPartition coefficientCrystallographyMembraneSpectrometry FluorescenceIonic strengthThermodynamicsBiopolymers
researchProduct

Expression of glial filament protein (GFP) in nerve sheaths and non-neural cells re-examined using monoclonal antibodies, with special emphasis on th…

1986

We describe two novel monoclonal antibodies specific for glial filament protein (GFP), i.e., GF12.23 and GF12.24 (both IgG2a]. These cross-react over a broad range of species with epitopes located in the alpha-helical rod domain typical of all intermediate filament (IF) proteins. These monoclonal antibodies were used, in conjunction with other monoclonal GFP antibodies, rabbit antiserum to GFP, and various antibodies to other cytoskeletal proteins, to examine the occurrence of GFP in cells outside of the central nervous system of rodents, cows, and humans. We detected some scattered GFP-containing cells in the neural sheaths in some species but not in others, and we obtained different resul…

AdenomaCancer Researchmedicine.drug_classGuinea PigsAdenoma PleomorphicFluorescent Antibody TechniqueCross ReactionsMonoclonal antibodyEyeEpitopeEpitheliumSalivary GlandsGreen fluorescent proteinEpitopesSpecies SpecificityGlial Fibrillary Acidic ProteinmedicineAnimalsHumansVimentinIntermediate filamentMolecular BiologyMyelin SheathbiologyMyoepithelial cellAntibodies MonoclonalCell BiologyMolecular biologyRatsMicroscopy FluorescenceMonoclonalImmunologybiology.proteinHepatic stellate cellKeratinsCattleAntibodyDevelopmental BiologyDifferentiation; research in biological diversity
researchProduct

Micellar Liquid Chromatography:  A Worthy Technique for the Determination of β-Antagonists in Urine Samples

1998

Several beta-antagonists (acebutolol, atenolol, celiprolol, labetalol, metoprolol, nadolol, propranolol) were determined in urine samples with fluorometric detection after direct injection, in less than 15 min, with a micellar mobile phase of 0.1 M sodium dodecyl sulfate (SDS), 15% propanol, and 1% triethylamine at pH 3. The limits of detection (38 criterion) were usually between 3 and 30 ng/mL. The addition of propanol and triethylamine and the reduction of the pH of the mobile phase improved the efficiency of the chromatographic peaks that was rather low in pure micellar eluents. The selection of the composition of the mobile phase was easily performed through the use of an interpretive p…

Adrenergic beta-Antagonists1-PropanolHigh-performance liquid chromatographyAnalytical ChemistryPropanolSurface-Active Agentschemistry.chemical_compoundEthylaminesmedicineHumansSodium dodecyl sulfateTriethylamineMicellesDetection limitChromatographySodium Dodecyl SulfateHydrogen-Ion ConcentrationAtenololPropranololAcebutololSpectrometry FluorescenceAtenololchemistryMicellar liquid chromatographyChromatography LiquidMetoprololmedicine.drugAnalytical Chemistry
researchProduct