Spontaneous fractures of the mandible concept & treatment strategy
2015
Background Spontaneous fractures of the mandible dispose a surgical challenge in comparisons to fractures caused by trauma due to several complicating factors. Additionally: controversies exist concerning the terminology of the field. Material and Methods We conducted a retrospective study of all patients with mandibular fractures, with exclusion of fractures of the coronoid process and the alveolar process, treated at the Department of Oral and Maxillofacial Surgery, Aalborg University Hospital, Denmark between February 2003 and February 2013. Data collected from the medical records included sex, age, cause of fracture, site of fracture, and treatment. Results We identified 517 patients wi…
High-energy extracorporeal shock wave treatment of nonunions.
2001
Forty-three consecutive patients who did not have healing of tibial or femoral diaphyseal and metaphyseal fractures and osteotomies for at least 9 months after injury or surgery were examined prospectively for use of high-energy extracorporeal shock waves. Former treatment modalities (cast, external fixator, plate osteosynthesis, limitation of weightbearing) remained unchanged. In all cases a 99m Technetium dicarboxyphosphonate regional two-phase bone scintigraphy was performed before one treatment with 3000 impulses of an energy flux density of 0.6 mJ/mm 2 . Radiologic and clinical followups were done at 4-week intervals starting 8 weeks after shock wave treatment. The success criterion wa…
Open Reduction and Internal Fixation of Low Subcondylar Fractures of Mandible Through High Cervical Transmasseteric Anteroparotid Approach
2009
Purpose The aim of the present study was to evaluate the functional and radiologic results of low subcondylar fracture fixation with modus TCP plates (Medartis, Basel, Switzerland) using a high cervical transmasseteric anteroparotid approach. Materials and Methods A prospective study was designed, enrolling all minimum-aged 15-year-old echomorphology patients presenting with displaced low subcondylar fracture with occlusion disturbances during a 41-month period. All fractures were fixed with modus TCP plates using high cervical transmasseteric anteroparotid approach. All patients underwent immediate physiotherapy and a 6-week liquid and semiliquid feeding period. Clinical and radiologic exa…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Post-traumatic lethal carotid-cavernous fistula.
2006
The authors report about an unexpected death by traumatic lesion of the internal carotid artery in a 30-year-old man who had fallen two metres. The man suffered a fracture of the left maxillary sinus and a fracture of the right orbit with bilateral haemorrhage of the maxillary sinus. Surgical treatment was performed with favorable outcome. Clinically, there were no neurological symptoms but about 60 days after his accident, the man died from uncontrolled epistaxis. He was submitted to the autopsy that show a linear fracture in the left side of the turcic sella and lesion of the left internal carotid artery with carotid-cavernous fistula.
Indications and limitations of the fixator TGF “Gex-Fix” in proximal end humeral fractures
2014
Abstract The incidence of fractures of the humerus has increased exponentially in recent years. The most used classifications for humerus fracture are morphological (Neer), biological (AO/ASIF) and descriptive (Hertel). The types of surgical treatment for humerus fracture include prosthetic replacement and synthesis using different devices, including the Tension Guide Fixator (TGF), Gex-Fix. External fixation for displaced proximal humeral fractures avoids dissection and soft tissue stripping and has been reported by some authors to be associated with higher union rates, a lower incidence of avascular necrosis, less scarring of the scapulohumeral interface, and faster rehabilitation compare…
Asymmetry of gait after free flap reconstruction of severe tibial fractures with extensive soft-tissue damage.
2000
Gait patterns of the preferred speed were investigated on 17 patients recovering (9 months-14 years) after reconstruction of severe tibial fractures. A novel data-acquisition system was used to record the plantar pressures as well as electromyographic (EMG) activities during walking. The results indicated incomplete recovery of symmetrical gait patterns. In particular, the duration of the stance phase was shorter on the operated side (mean (SD) 701 (90) ms compared with 765 (128) ms, p < 0.001). The peak pressure points under the foot were different on bilateral comparison, the operated side being regularly higher under the lateral forefoot area. This may imply attempts to reduce the loadin…
Clinical performance of a new medullary humeral nail: antegrade versus retrograde insertion.
2001
Objective A new intramedullary nail system for humeral shaft fractures is evaluated to determine whether retrograde nailing is as reliable as antegrade nailing. Study design Prospective multicenter nonrandomized clinical study. Patients Eighty-four patients with acute humeral shaft fractures were nailed with the new unreamed humeral nail (UHN) system. Fifty-seven nails were introduced retrogradely, and twenty-seven antegradely. Bone healing and functional outcome were the follow-up parameters. Results The ratio of perioperative complications was equivalent for both groups, but one shaft fracture and three fractures or fissures at the entry point occurred in the group with retrograde nail in…
Functional results after operative treatment of olecranon fractures.
2004
In a retrospective, nonrandomized study, we reviewed our experience with the operative treatment of olecranon fractures to find out which factors correlate with subjective complaints and functional outcome. A total of 95 consecutive olecranon fractures were operatively treated in our level I trauma institution between March 1, 1992 and March 1, 2000. Medical charts and radiographs of all patients were evaluated. Three patients died, 23 were lost to follow-up. Fifty-eight of 69 available patients (84.0%) were reviewed clinically and/or radiologically after a mean time interval of 36 months. Fracture type, fracture classification, associated lesions, technical correctness of osteosynthesis, a…
Olecranon fractures in adults: factors influencing outcome.
2003
In a retrospective, non-randomized study, we reviewed our experience with the operative treatment of olecranon fractures to find out which factors correlate with subjective complaints and functional outcome. A total of 95 consecutive olecranon fractures were operatively treated in our level I trauma institution between 1 March 1992 and 1 March 2000. Medical records and X-rays of all patients were evaluated. Three patients died, 23 were lost to follow-up. Fifty-eight of 69 available patients (84.0%) were reviewed clinically and/or radiologically after a mean time of 36 months. Fracture type, fracture classification, associated lesions, technical correctness of osteosynthesis, age and comorbi…