Search results for " Image"

showing 10 items of 3936 documents

Effects of motor imagery on strength, range of motion, physical function, and pain intensity in patients with total knee arthroplasty: A systematic r…

2021

Abstract Background In the early stages of total knee arthroplasty (TKA) rehabilitation, in which physical function in general can be affected, motor imagery (MI) might play a relevant role. Objective To assess the impact of MI on strength, active range of motion (ROM), pain intensity, and physical function in patients with TKA. Methods We conducted a systematic review and meta-analysis of randomised controlled trials. Pooled effects were calculated as standardised mean differences (SMDs) and 95% confidence intervals (CIs) for the relevant outcomes using random effects model. The certainty of evidence was assessed with GRADE approach. Results This review included 7 articles. The addition of…

medicine.medical_specialtyRehabilitationbusiness.industrymedicine.medical_treatmentRehabilitationPhysical Therapy Sports Therapy and RehabilitationPhysical functionRandom effects modelConfidence intervalIntensity (physics)Quadriceps MuscleMotor imageryMeta-analysismedicinePhysical therapyHumansOrthopedics and Sports MedicineSystematic ReviewRange of Motion ArticularRange of motionbusinessArthroplasty Replacement KneePain Measurement
researchProduct

Relationship between Skin Temperature Variation and Muscle Damage Markers after a Marathon Performed in a Hot Environmental Condition

2021

This study aimed to assess the effect of a marathon running at a hot environmental temperature on the baseline skin temperature (Tsk) of the posterior day and to analyze the relationship between Tsk response and muscle damage markers variation. The Tsk, creatine kinase, and lactate dehydrogenase of 16 marathon runners were assessed four times before (15 days and 45 min) and after (24 h and 6 days) a marathon in a hot environment (thermal stress index = 28.3 ± 3.3 °C and humidity ~81%). The Tsk of thirteen different body regions of both right and left lower limbs were analyzed. Higher values after the marathon were observed than 45 min before in creatine kinase (174.3 ± 136.4 UI/L &lt

medicine.medical_specialtyScienceVasodilationthermal imageMuscle damageArticleGeneral Biochemistry Genetics and Molecular Biology03 medical and health scienceschemistry.chemical_compoundrecovery0302 clinical medicineLactate dehydrogenaseInternal medicinemedicineEcology Evolution Behavior and SystematicsendurancebiologyGlycogenbusiness.industrycreatine kinaseEndothelial nitric oxideQPaleontologySkin temperature030229 sport sciencesEndocrinologychemistrySpace and Planetary Scienceinfrared thermographybiology.proteinBody regionCreatine kinasebusinesshuman activities030217 neurology & neurosurgeryLife
researchProduct

May Dyspnea Sensation Influence the Sexual Function in Men With Obstructive Sleep Apnea Syndrome? A Prospective Control Study

2019

Abstract Introduction Dyspnea sensation is frequently present in obstructive sleep apnea syndrome (OSA) patients; however, its possible influence on sexual function and body image has not been well analyzed. Aims To evaluate sexual function, the prevalence of sexual dysfunction (SD), and body image during sexual activity and its relationship with dyspnea in men with OSA. Methods 129 men were included in the prospective study, with 61 diagnosed with OSA (cases) and 68 age- and BMI-matched healthy control subjects. Patients were assessed for the severity of heart failure by the New York Heart Association scale and dyspnea by the Visual Analogue Scale. OSA was confirmed by in-laboratory polyso…

medicine.medical_specialtySexual DysfunctionVisual analogue scaleUrologyEndocrinology Diabetes and MetabolismPopulation030232 urology & nephrologylcsh:MedicineDermatologyPolysomnographyMen's Sexual Health03 medical and health sciencesBehavioral Neuroscience0302 clinical medicineEndocrinologyInternal medicinemedicineBody ImageeducationProspective cohort studySexual Functioneducation.field_of_study030219 obstetrics & reproductive medicinemedicine.diagnostic_testbusiness.industrylcsh:RObstructive Sleep Apnea Syndromelcsh:Other systems of medicinelcsh:RZ201-999medicine.diseaserespiratory tract diseasesObstructive sleep apneaPsychiatry and Mental healthSexual dysfunctionDyspneaReproductive MedicineHeart failuremedicine.symptomSexual functionbusinessSexual Medicine
researchProduct

Multi-spectral skin imaging by a consumer photo-camera

2010

The possibilities to perform multi-band spectral imaging by means of a consumer color camera without external filters have been studied. Images at up to 6 spectral bands may be extracted from a single color image after appropriate signal processing. The proposed technique was tested in pilot measurements of in-vivo skin hemoglobin maps and laser-excited autofluorescence images.

medicine.medical_specialtySignal processingMaterials sciencebusiness.industryColor imagePhysics::Medical PhysicsHyperspectral imagingSpectral bandsLaserSpectral imaginglaw.inventionImaging spectroscopyAutofluorescenceOpticslawComputer Science::Computer Vision and Pattern RecognitionmedicinebusinessSPIE Proceedings
researchProduct

High Dynamic Range Spectral Imaging Pipeline For Multispectral Filter Array Cameras

2017

Spectral filter arrays imaging exhibits a strong similarity with color filter arrays. This permits us to embed this technology in practical vision systems with little adaptation of the existing solutions. In this communication, we define an imaging pipeline that permits high dynamic range (HDR)-spectral imaging, which is extended from color filter arrays. We propose an implementation of this pipeline on a prototype sensor and evaluate the quality of our implementation results on real data with objective metrics and visual examples. We demonstrate that we reduce noise, and, in particular we solve the problem of noise generated by the lack of energy balance. Data are provided to the community…

medicine.medical_specialtySimilarity (geometry)Computer sciencePipeline (computing)Multispectral imageComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONspectral imaging02 engineering and technology[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processinglcsh:Chemical technology01 natural sciencesBiochemistryArticleAnalytical Chemistry010309 optics[SPI]Engineering Sciences [physics]Color gel0103 physical sciences[ INFO.INFO-TI ] Computer Science [cs]/Image Processing0202 electrical engineering electronic engineering information engineeringmedicine[ SPI ] Engineering Sciences [physics]Computer visionlcsh:TP1-1185Electrical and Electronic EngineeringInstrumentationHigh dynamic rangeComputingMilieux_MISCELLANEOUSbusiness.industryhigh dynamic rangespectral filter arraysAtomic and Molecular Physics and Opticsspectral imaging; spectral filter arrays; high dynamic range; image databaseSpectral imagingNoiseFilter (video)[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]020201 artificial intelligence & image processingArtificial intelligencebusiness[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingimage database
researchProduct

EPR dosimetry intercomparison using smart phone touch screen glass

2014

International audience; This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogene…

medicine.medical_specialtySmart phoneMass casualty eventStatistics as TopicBiophysicsEPR dosimetry[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]EPR Dosimetry Elecron Paramagnetic Resonance in phone touch screen glass.01 natural sciencesRetrospective dosimetry030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineTest material0103 physical sciencesmedicineHumansDosimetryMedical physicsRadiometryGeneral Environmental Science010302 applied physicsRadiationDosimeterbusiness.industryElectron Spin Resonance SpectroscopyRadiological emergencySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Critical levelHomogeneousCalibrationEpr dosimetryGlassbusinessNuclear medicine[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingCell Phone
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct

Accuracy of automatic airway morphometry in computed tomography-correlation of radiological-pathological findings.

2010

Abstract Objectives Airway morphology shows characteristic changes in different pathologies. This study assesses the accuracy of a current automatic airway assessment technique by correlating CT images of porcine airways to histological slices of the same localization. Materials and methods Four isolated and ventilated porcine lungs were frozen in a liquid nitrogen bath and examined with a CT scanner (MDCT). This technique both preserved normal radiomorphological appearance and made it possible to slice the specimens for histological examination for subsequent correlation. The parameters wall thickness (WT), wall percentage (WP), and total diameter (TD) were assessed by computer-aided measu…

medicine.medical_specialtySwineStatistics as TopicBronchiIn Vitro TechniquesSensitivity and SpecificityImaging phantomPattern Recognition AutomatedCorrelationBronchoscopyMedicineAnimalsRadiology Nuclear Medicine and imagingPathologicalbusiness.industryReproducibility of ResultsHistologyGeneral MedicineTracheaRadiological weaponCalipersRadiographic Image Interpretation Computer-AssistedRadiologyTomographybusinessAirwayNuclear medicineTomography X-Ray ComputedAlgorithmsEuropean journal of radiology
researchProduct

Towards EEG-Based Haptic Interaction within Virtual Environments

2019

International audience; Current virtual environments (VE) enable perceiving haptic stimuli to facilitate 3D user interaction, but lack brain-interfacial contents. Using electroencephalography (EEG), we undertook a feasibility study on exploring event-related potential (ERP) patterns of the user's brain responses during haptic interaction within a VE. The interaction was flying a virtual drone along a curved transmission line to detect defects under the stimuli (e.g., force increase and/or vibrotactile cues). We found that there were variations in the peak amplitudes and latencies (as ERP patterns) of the responses at about 200 ms post the onset of the stimuli. The largest negative peak occu…

medicine.medical_specialtySynthèse d'image et réalité virtuelle [Informatique]Computer science[INFO.INFO-GR] Computer Science [cs]/Graphics [cs.GR]02 engineering and technologyAudiologyElectroencephalographyVirtual realityVibrationEvent-related potential (ERP)Virtual reality0202 electrical engineering electronic engineering information engineeringmedicine[INFO.INFO-HC]Computer Science [cs]/Human-Computer Interaction [cs.HC]Electroencephalography (EEG)ForceHaptic technologyHaptic interactionmedicine.diagnostic_test020207 software engineeringHaptic stimuli[INFO.INFO-GR]Computer Science [cs]/Graphics [cs.GR]Interface homme-machine [Informatique]020201 artificial intelligence & image processing[INFO.INFO-HC] Computer Science [cs]/Human-Computer Interaction [cs.HC]
researchProduct

Is Kelami's Method Still Useful in the Smartphone Era? The Virtual 3-Dimensional Reconstruction of Penile Curvature in Patients With Peyronie's Disea…

2021

Abstract Background Peyronie's disease is an idiopathic fibrotic disease affecting the penile tunica albuginea. Among other resulting deformities, the more common penile curvature should be assessed preferentially with in-office goniometric estimation after pharmacologically induced erection, although clearly invasive and uncomfortable. Aim In the present pilot study, we investigated the usefulness for the patient and the surgeon of a 3-dimensional (3D) reconstruction of the penile curvature obtained through photogrammetry software in clinical evaluation and surgical planning. Methods Enrolled patients received alprostadil 10 μg by intracavernous injection. Then, the medical personnel took …

medicine.medical_specialtyUrologyEndocrinology Diabetes and MetabolismPreoperative counseling030232 urology & nephrologyIntracavernous injectionSurgical planning03 medical and health sciences0302 clinical medicineEndocrinologymedicineIn patientReconstructive Surgical Procedures030219 obstetrics & reproductive medicinePeyronie's DiseaseGroinbusiness.industryGeneral surgerymedicine.diseasePsychiatry and Mental healthmedicine.anatomical_structureReproductive MedicineThree-Dimensional ImageComputer-Assisted DiagnosisPenile curvaturePeyronie's diseasebusinessPenis
researchProduct