Search results for " Informatica"

showing 10 items of 978 documents

Cardiovascular and autonomic responses to physiological stressors before and after six hours of water immersion

2013

The physiological responses to water immersion (WI) are known; however, the responses to stress following WI are poorly characterized. Ten healthy men were exposed to three physiological stressors before and after a 6-h resting WI (32–33°C): 1) a 2-min cold pressor test, 2) a static handgrip test to fatigue at 40% of maximum strength followed by postexercise muscle ischemia in the exercising forearm, and 3) a 15-min 70° head-up-tilt (HUT) test. Heart rate (HR), systolic and diastolic blood pressure (SBP and DBP), cardiac output (Q̇), limb blood flow (BF), stroke volume (SV), systemic and calf or forearm vascular resistance (SVR and CVR or FVR), baroreflex sensitivity (BRS), and HR variabili…

AdultMalemedicine.medical_specialtyPhysiologyBlood PressureStatic exerciseCardiovascular SystemCold pressorWater immersionHeart RateStress PhysiologicalTilt-Table TestInternal medicinePhysiology (medical)ImmersionMedicineHeart rate variabilityHumansAutonomic nervous systemCardiac OutputStatic ExerciseHeart rate variabilityHand Strengthbusiness.industryStressorCold pressor testHemodynamicsWaterStroke VolumeBaroreflexPhysiological responsesAutonomic nervous systemForearmEndocrinologyWater immersionRegional Blood FlowSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaVascular Resistancebusinesscirculatory and respiratory physiologyOrthostatic tolerance
researchProduct

Measuring postural-related changes of spontaneous baroreflex sensitivity after repeated long-duration diving: Frequency domain approaches

2012

Sustained water immersion is thought to modulate orthostatic tolerance to an extent dependent on the duration and repetition over consecutive days of the diving sessions. We tested this hypothesis investigating in ten healthy subjects the potential changes in the cardiovascular response to head-up tilt induced by single and multiple resting air dives. Parametric cross-spectral analysis of spontaneous RR interval and systolic arterial pressure variability was performed in three experimental sessions: before diving (BD), after single 6-hour dive (ASD), and after multiple 6-hour dives (AMD, 5 consecutive days with 18-hour surface interval). From this analysis, baroreflex sensitivity (BRS) was …

AdultMalemedicine.medical_specialtySupine positionDivingPostureRR intervalOrthostatic intoleranceBaroreflexSensitivity and SpecificityEndocrine and Autonomic SystemCellular and Molecular NeuroscienceOrthostatic vital signsInternal medicinemedicineHumansShort durationAnalysis of VarianceElectronic Data ProcessingEndocrine and Autonomic Systemsbusiness.industrySpectrum AnalysisHead-up tiltBaroreflexCardiovascular variabilitymedicine.diseaseCausal coherenceParametric cross-spectral analysiFrequency domainSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaPower ratioCardiologyNeurology (clinical)businessOrthostatic toleranceAutonomic Neuroscience
researchProduct

Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure

2011

We validated a prototype cuff-free device for noninvasive estimation of blood pressure (BP). The system assumed a linear relation between BP values and the inverse of arterial blood pulse transit time, measured as time interval between the R wave on the electrocardiograph and the onset of the peripheral pulse wave on a finger plethysmogram. Thirty-three healthy subjects were analyzed at rest and during increasing stress exercise. To estimate subject-specific linear model parameters, the system was calibrated ad personam with reference to BP measures obtained by a cuff sphygmomanometer. High correlation values (R2= 0.89 and 0.78 for systolic and diastolic BP, respectively) and differences co…

AdultMalemedicine.medical_specialtySystoleDiastolePulse transit timeSphygmomanometerSensitivity and SpecificityQRS complexDiastoleInternal medicineValidationmedicineHumansDiagnosis Computer-AssistedSystolePhotoplethysmographyAccuracyAgedbusiness.industryReproducibility of ResultsBlood Pressure DeterminationEquipment DesignMiddle AgedSphygmomanometersConfidence intervalSurgeryBlood pressure monitoringEquipment Failure AnalysisBlood pressurePulsatile FlowCuffSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaElectrocardiography AmbulatoryCardiologyNoninvasive measurementFeasibility StudiesArterial bloodFemalebusinessCardiology and Cardiovascular Medicine
researchProduct

Conditional Self-Entropy and Conditional Joint Transfer Entropy in Heart Period Variability during Graded Postural Challenge.

2015

Self-entropy (SE) and transfer entropy (TE) are widely utilized in biomedical signal processing to assess the information stored into a system and transferred from a source to a destination respectively. The study proposes a more specific definition of the SE, namely the conditional SE (CSE), and a more flexible definition of the TE based on joint TE (JTE), namely the conditional JTE (CJTE), for the analysis of information dynamics in multivariate time series. In a protocol evoking a gradual sympathetic activation and vagal withdrawal proportional to the magnitude of the orthostatic stimulus, such as the graded head-up tilt, we extracted the beat-to-beat spontaneous variability of heart per…

AdultMalemedicine.medical_specialtygenetic structuresEntropyPosturelcsh:MedicineMedicine (all); Biochemistry Genetics and Molecular Biology (all); Agricultural and Biological Sciences (all)Orthostatic vital signsYoung AdultInternal medicineLinear regressionmedicineHumanslcsh:ScienceMathematicsBiochemistry Genetics and Molecular Biology (all)MultidisciplinaryMedicine (all)lcsh:RHealthy subjectsHeart period variabilityHeartSignal Processing Computer-AssistedMiddle AgedBlood pressureAgricultural and Biological Sciences (all)Settore ING-INF/06 - Bioingegneria Elettronica E InformaticaReflexCardiologylcsh:QTransfer entropyFemaleInformation dynamicsResearch ArticlePloS one
researchProduct

Surrogate data approaches to assess the significance of directed coherence: Application to EEG activity propagation

2009

This paper addresses the topic of evaluating the significance of frequency domain measures of causal coupling in multivariate time series through generation of surrogate data. The considered approaches are the traditional Fourier Transform (FT) algorithm and a new causal FT (CFT) algorithm for surrogate data generation. Both algorithms preserve the FT modulus of the original series; differences are in the phase relationships, that are completely destroyed for FT surrogates and imposed after switching off the link over the considered causal direction for CFT surrogates. The ability of the algorithms to assess causality in the frequency domain was tested using the directed coherence as discri…

AdultMultivariate statisticsSpeech recognitionBiomedical EngineeringElectroencephalographySurrogate datasymbols.namesakemedicineHumansCoherence (signal processing)Diagnosis Computer-AssistedMathematicsmedicine.diagnostic_testbusiness.industryMedicine (all)BrainElectroencephalographySignal Processing Computer-AssistedPattern recognitionCell BiologyFourier transformEeg activityData Interpretation StatisticalFrequency domainSettore ING-INF/06 - Bioingegneria Elettronica E InformaticasymbolsDirect couplingArtificial intelligenceNerve NetbusinessAlgorithmsDevelopmental Biology2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
researchProduct

Testing Frequency-Domain Causality in Multivariate Time Series

2010

We introduce a new hypothesis-testing framework, based on surrogate data generation, to assess in the frequency domain, the concept of causality among multivariate (MV) time series. The approach extends the traditional Fourier transform (FT) method for generating surrogate data in a MV process and adapts it to the specific issue of causality. It generates causal FT (CFT) surrogates with FT modulus taken from the original series, and FT phase taken from a set of series with causal interactions set to zero over the direction of interest and preserved over all other directions. Two different zero-setting procedures, acting on the parameters of a MV autoregressive (MVAR) model fitted on the ori…

AdultMultivariate statisticsTime FactorsBiomedical EngineeringSurrogate datasymbols.namesakemultivariate autoregressive (MVAR) modeldirected coherence (DC)StatisticsHumansCoherence (signal processing)Computer SimulationEEGMathematicsSignal processingsurrogate dataFourier Analysispartial directed coherence (PDC)Models CardiovascularReproducibility of ResultsEstimatorElectroencephalographySignal Processing Computer-AssistedCardiovascular variabilityFourier transformAutoregressive modelFrequency domainMultivariate AnalysisSettore ING-INF/06 - Bioingegneria Elettronica E InformaticasymbolsAlgorithmAlgorithmsIEEE Transactions on Biomedical Engineering
researchProduct

Time-Varying Surrogate Data to Assess Nonlinearity in Nonstationary Time Series: Application to Heart Rate Variability

2009

We propose a method to extend to time-varying (TV) systems the procedure for generating typical surrogate time series, in order to test the presence of nonlinear dynamics in potentially nonstationary signals. The method is based on fitting a TV autoregressive (AR) model to the original series and then regressing the model coefficients with random replacements of the model residuals to generate TV AR surrogate series. The proposed surrogate series were used in combination with a TV sample entropy (SE) discriminating statistic to assess nonlinearity in both simulated and experimental time series, in comparison with traditional time-invariant (TIV) surrogates combined with the TIV SE discrimin…

AdultTime FactorsComputer scienceRestBiomedical EngineeringSurrogate dataHeart RateStatisticsHumansHeart rate variabilityEntropy (information theory)Computer SimulationNonstationarityEntropy (energy dispersal)Time seriesEntropy (arrow of time)StatisticModels StatisticalEntropy (statistical thermodynamics)RespirationNonlinear dynamicModels CardiovascularComplexitySample entropyNonlinear systemNonlinear DynamicsAutoregressive modelSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaSurrogate dataTime-varying (TV) autoregressive (AR) modelHeart rate variability (HRV)AlgorithmsEntropy (order and disorder)IEEE Transactions on Biomedical Engineering
researchProduct

Assessing Causality in normal and impaired short-term cardiovascular regulation via nonlinear prediction methods

2009

We investigated the ability of mutual nonlinear prediction methods to assess causal interactions in short-term cardiovascular variability during normal and impaired conditions. Directional interactions between heart period (RR interval of the ECG) and systolic arterial pressure (SAP) short-term variability series were quantified as the cross-predictability (CP) of one series given the other, and as the predictability improvement (PI) yielded by the inclusion of samples of one series into the prediction of the other series. Nonlinear prediction was performed through global approximation (GA), approximation with locally constant models (LA0) and approximation with locally linear models (LA1) …

Adultmedicine.medical_specialtySupine positionTime FactorsGeneral MathematicsRR intervalGlobal nonlinear predictionGeneral Physics and AstronomyNeurally-mediated syncopeBlood PressureK-nearest neighbours local nonlinear predictionCardiovascular SystemSyncopeCardiovascular Physiological PhenomenaPhysics and Astronomy (all)Engineering (all)Control theoryHeart RateNeurally mediated syncopeInternal medicinemedicinePressureHumansMathematics (all)Computer SimulationOut-of-sample predictionMathematicsModels StatisticalGeneral EngineeringLinear modelModels CardiovascularNonlinear granger causalityModels TheoreticalControl subjectsHeart rate and arterial pressure variabilityCausalityNonlinear predictionTerm (time)Case-Control StudiesSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaCardiologyAlgorithms
researchProduct

Investigating the level of significance of the coherence function in cardiovascular variability analysis

2002

Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), spectral estimator parameters should also be considered. In this study, the surrogate data technique was introduced to define the level of significance of the CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate the CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parame…

Analysis of covarianceThreshold limit valueFrequency domainStatistical significanceStatisticsSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaEstimatorCoherence (signal processing)Cardiology and Cardiovascular MedicineTransfer functionSoftwareMathematicsSurrogate data
researchProduct

Comparison of discretization strategies for the model-free information-theoretic assessment of short-term physiological interactions

2023

This work presents a comparison between different approaches for the model-free estimation of information-theoretic measures of the dynamic coupling between short realizations of random processes. The measures considered are the mutual information rate (MIR) between two random processes [Formula: see text] and [Formula: see text] and the terms of its decomposition evidencing either the individual entropy rates of [Formula: see text] and [Formula: see text] and their joint entropy rate, or the transfer entropies from [Formula: see text] to [Formula: see text] and from [Formula: see text] to [Formula: see text] and the instantaneous information shared by [Formula: see text] and [Formula: see…

Applied MathematicsSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaGeneral Physics and AstronomyStatistical and Nonlinear PhysicsInformation-theoretic measures mutual information rate (MIR) binning permutation time-series analysisMathematical Physics
researchProduct