Search results for " Instrumentation."
showing 10 items of 712 documents
Calibration of the XRT-SOLARB flight filters at the XACT facility of INAF-OAPA
2004
The X-Ray Telescope (XRT) experiment on-board the Japanese satellite SOLAR-B (launch in 2006) aimed at providing full Sun field of view at ~ 1.5" angular resolution, will be equipped with two wheels of focal-plane filters to select spectral features of X-ray emission from the Solar corona, and a front-end filter to significantly reduce the visible light contamination. We present the results of the X-ray calibrations of the XRT flight filters performed at the X-ray Astronomy Calibration and Testing (XACT) facility of INAF-OAPA. We describe the instrumental set-up, the adopted measurement technique, and present the transmission vs. energy and position measurements.
Calibration of the XRT-SOLARB flat mirror samples at the XACT Facility of INAF-OAPA
2004
The X-Ray Telescope (XRT) experiment on-board the Japanese satellite SOLAR-B (launch in 2006) is equipped with a modified Wolter I grazing incidence X-ray telescope (focal length 2700 mm) to image the full Sun at ~ 1.5" angular resolution onto a 2048 x 2048 back illuminated CCD focal plane detector. The X-ray telescope consisting of one single reflecting shell is coated with ion beam sputtered Iridium over a binding layer of Chromium to provide nearly 5 square centimetres effective area at 60 A. We present preliminary results of X-ray calibrations of the XRT flat mirror samples performed at the X-ray Astronomy Calibration and Testing (XACT) facility of INAF-OAPA. We describe the instrumenta…
High Energy, High Resolution X-Ray Spectroscopy: Microcalorimeters For Nuclear Line Astrophysics
2005
We introduce focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics with a balloon payload concept called, B‐MINE. It is designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the velocity distribution of the 44Ti emitting region. B‐MINE has a thin plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3σ sensitivity in 106 s of 6 × 10−8 ph cm−2 s−1 at …
Calibration of the Lunar Orbital X-ray Fluorescence Imaging Spectrometer (LOXIA) of Chang'E-1 satellite at INAF-OAPA
2007
The Lunar Orbital X-ray Fluorescence Imaging Spectrometer (LOXIA) designed and constructed at the Institute of High Energy Physics of the Chinese Academy of Sciences to perform chemical composition analysis of the Moon surface will operate on-board the Chang'E-1 mission, the first Chinese lunar spacecraft to be launched in 2007. We report the main results of the calibration measurements that we have performed using the X-ray beamline of the XACT facility of INAFOsservatorio Astronomico di Palermo G.S. Vaiana to determine the quantum efficiency of the XRS detector in the soft X-rays as a function of photon energy and angle of incidence.
The Palermo XACT facility: a new 35 m long soft x-ray beam-line for the development and calibration of next-generation x-ray observatories
2006
The X-ray Astronomy Calibration and Testing (XACT) facility of the Instituto Nazionale di Astrofisica (INAF) at Osservatorio Astronomico di Palermo has recently undergone a major upgrade with the design and construction of a 35 meter long vacuum beam-line operating in the soft X-rays (0.1-20 keV) and the addition of new hardware to meet the requirements for testing and calibration of next generation X-ray missions. We report on the present configuration of the facility and briefly survey the range of its applications.
Simbol-X Mirror Module Thermal Shields: I-Design and X-Ray Transmission
2009
The Simbol‐X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X‐ray transmission.
Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters
2013
After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons lear…
Background Rejection of Charged Particles in the Simbol-X Telescope: Preliminary Study of Protons Scattering
2009
X-ray telescopes equipped with focusing optics in high eccentric orbit, as e.g. Newton-XMM and Chandra, showed a degradation of the detector performance and an important increase of the noise due to soft protons with energy between a few tens of keV and a few MeV, that are focused on the detector through the mirror module. It should be noted that the focusing of the protons by Wolter optics was an unexpected phenomenon. In Simbol-X a magnetic diverter will be implemented to deflect protons, in order to reduce the flux of charged particles impinging upon the focal plane. Obviously the design of the diverter should take into consideration the protons distribution at the exit of the mirror mod…
Chaos and nonlinearities in high harmonic generation
2016
Linearity is a fundamental postulate of quantum mechanics which is occasionally the subject of debate. This paper investigates the possibility of checking this assumption by using a laser field. We study the corrections caused by the presence of a small nonlinearity in the Hamiltonian of a quantum system. As a model we use a simplified two-level quantum system whose states are coupled by a small off-diagonal term proportional to the population of the upper level. The nonlinearity causes spontaneous decay of the upper level, shift and broadening of the line and the sensitive dependence of the final state on the initial condition. The presence of a strong laser field, resonant with the atomic…
Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation II: analysis of in-flight data
2013
After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton we have reviewed the status of its thin and medium filters by performing both analysis of data collected in-flight and laboratory measurements on on-ground back-up filters. We have investigated the status of the EPIC thin and medium filters by performing an analysis of the optical loading in the PN offset maps to gauge variations in the optical and UV transmission of the filters. We both investigated repeated observations of single optically bright targets and performed a statistical analysis of the extent of loading versus visual magnitude at different epochs. We report the results of these …