Search results for " Instruments"

showing 10 items of 187 documents

The subway tunneling technique for distal shunt catheter insertion.

2019

Dear Editor,We read with interest the article by Osman et al. titled ‘Trocar assisted distal shunt tube insertion with intra-operative X-Ray confirmation’. The authors purpose their technique to pl...

medicine.medical_specialtyCatheter insertionHydrocephalubusiness.industryX-RaysGeneral MedicineSurgical InstrumentsSurgical InstrumentVentriculoperitoneal ShuntSurgeryShunt (medical)medicineHumansSurgeryRailroadNeurology (clinical)businessRailroadsHumanHydrocephalusBritish journal of neurosurgery
researchProduct

Pediatric oncologic endosurgery.

2017

Despite increasing popularity of minimal-invasive techniques in the pediatric population, their use in diagnosis and management of pediatric malignancy is still debated. Moreover, there is limited evidence to clarify this controversy due to low incidence of each individual type of pediatric tumor, huge diversity of the disease entity, heterogeneity of surgical technique, and lack of well-designed studies on pediatric oncologic minimal-invasive surgery. However, a rapid development of medical instruments and technologies accelerated the current trend toward less invasive surgery, including oncologic endosurgery. The aim of this article is to review current literatures about the application o…

medicine.medical_specialtyDisease entitybusiness.industryThoracoscopyMedical instrumentsLess invasive surgeryPediatric TumorEndosurgeryGeneral Medicine03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisPediatric malignancySolid tumorsmedicine030211 gastroenterology & hepatologyLaparoscopyLimited evidenceIntensive care medicinebusinessReview ArticlesChildrenPediatric populationInternational journal of surgery. Oncology
researchProduct

Simplified orthotopic ileocaecal pouch (Mainz pouch) for bladder substitution

2005

medicine.medical_specialtyIntraoperative CareUrinary bladderbusiness.industrySurgical staplingPatient SelectionUrologySuture TechniquesUrinary Reservoirs ContinentUrologyUrinary DiversionSurgical InstrumentsSurgeryKock pouchmedicine.anatomical_structureMedical IllustrationSurgical StaplingHumansMedicineBladder substitutionAnatomy ArtisticPouchbusinessUrinary pouchBJU International
researchProduct

New applicator improves waterjet dissection quality

2010

Waterjet dissection is accomplished with Helix Hydro-Jet, but a new device with improved operative handling and potentially superior dissection qualities has been developed.Eighty-four fresh cadaveric pig brains were simultaneously cut with Helix Hydro-Jet and Erbejet 2. A commonly used applicator and a new applicator for the Helix Hydro-Jet were directly compared to the new Erbejet 2. Under standardised conditions, different pressure levels were applied to the brain surface without arachnoids. Technical features, cutting depth, tissue damage and differences of applicators were examined.Microscopic analysis of cutting depth revealed different dissection characteristics of both the devices. …

medicine.medical_specialtySwineHydrostatic pressureBrain surfaceDissection (medical)Neurosurgical ProceduresTissue damageHydrostatic PressuremedicineAnimalsNew devicebusiness.industryDissectionBrainEquipment DesignGeneral MedicineSurgical Instrumentsmedicine.diseaseSurgeryArachnoidsModels AnimalSurgeryNeurology (clinical)businessCadaveric spasmBiomedical engineeringBritish Journal of Neurosurgery
researchProduct

The use of a new kind of low profile retractor for arteriovenous fistula procedure simplifies and speeds up the intervention

2009

Purpose The aim of this study was to demonstrate the effectiveness of a new kind of disposable surgical retractor in arteriovenous fistula (AVF) procedures in order to achieve an easier, faster and safer surgical intervention. Methods Between January and June 2008, 22 AVF procedures were performed using the 3PAWS ReeTrakttrade; (Insightra Inc. - Irvine, Ca., USA) a self-retaining, low profile retractor. An equivalent patient sample, in which an AVF was performed using conventional retraction devices, was considered for comparison of the intra- and post-operative results. Results In all of the 22 AVF procedures performed, the ReeTrakt™ system has simplified the performance of the surgical te…

medicine.medical_specialtyTime Factorsmedicine.medical_treatment030232 urology & nephrologyArteriovenous fistulaarterioveunous fistula retractors030204 cardiovascular system & hematology03 medical and health sciencesArteriovenous Shunt Surgical0302 clinical medicineOperating timeHumansMedicinePatient groupDisposable EquipmentReduction (orthopedic surgery)Brachiocephalic VeinsRetrospective StudiesSurgical teamSurgical instrumentationSurgical Fixation Devicebusiness.industryEquipment DesignSurgical Instrumentsmedicine.diseasearteriovenous fistulaReeTrakt systemSurgeryRetractorForearmSettore MED/18 - Chirurgia GeneraleTreatment OutcomeNephrologyRadial ArterySurgerybusiness
researchProduct

Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…

2017

Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…

medicine.medical_specialtyWilcoxon signed-rank testImage qualityComputed Tomography Angiographymedicine.medical_treatmentContrast MediaMagnetic resonance angiography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAneurysmMcNemar's testmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesComputed tomography angiographyRetrospective Studiesmedicine.diagnostic_testbusiness.industryIntracranial AneurysmGeneral MedicineClipping (medicine)Prostheses and Implantsmedicine.diseaseImage EnhancementSurgical InstrumentsCerebral AngiographyMetalscardiovascular systemStentsImplantRadiologybusinessArtifacts030217 neurology & neurosurgeryMagnetic Resonance AngiographyFollow-Up StudiesClinical radiology
researchProduct

Sentinel lymph node BIOPSY after neoadjuvant therapy in breast cancer patients with lymph node involvement at diagnosis. Could wire localization of c…

2021

Abstract Introduction Sentinel lymph node biopsy (SLNB) after neoadjuvant therapy (NAT) in node-positive (N+) breast cancer patients at diagnosis remains a controversial issue, with no consensus on implementation or safety. Objectives We sought to assess the accuracy of SLNB after NAT in biopsy-proven N+ cases at diagnosis and the efficacy and accuracy of wire localization of the clipped node to improve results. Material and methods A cross-sectional diagnostic technique validation study in N+ patients following NAT was performed. The biopsy-proven affected lymph node was clipped at diagnosis. SLNB and axillary lymph node dissection (ALND) were performed in cases of clinical-radiological ly…

medicine.medical_specialtymedicine.medical_treatmentWire localizationSentinel lymph nodeBreast Neoplasms03 medical and health sciences0302 clinical medicineBreast cancerBiopsymedicineHumans030212 general & internal medicineLymph nodeNeoadjuvant therapyNeoplasm Stagingmedicine.diagnostic_testbusiness.industrySentinel Lymph Node BiopsyAxillary Lymph Node DissectionMiddle Agedmedicine.diseaseSurgical InstrumentsNeoadjuvant Therapymedicine.anatomical_structureCross-Sectional Studies030220 oncology & carcinogenesisLymphatic MetastasisAxillaLymph Node ExcisionSurgeryNode (circuits)FemaleRadiologyLymph NodesSentinel Lymph NodebusinessThe surgeon : journal of the Royal Colleges of Surgeons of Edinburgh and Ireland
researchProduct

L’UTILIZZO IN MEDICINA LEGALE DELLA MISURAZIONEDELLA SALUTE DEL MINORE SECONDO ICF-CY: ESEMPLIFICA-ZIONE CASISTICA

2015

The evaluation of minors within welfare contest requires an adequate multidisciplinary and interdisciplinary approach to clinical and psycho-social order. There are many evaluation’s instruments, but in the medico legal context particularly useful is the evaluation according to the guidelines of the World Health Organization, in the recent codification ICF, International Classification of Functioning, Disability and Health [1] version YC (Children and Youth) [2]. The use of minor measurement according to ICF-CY is here reported in a child’s health experience with neuropsychiatric disorders. The system ICF-CY offers a revolutionary new model that relates biological, psychological and social …

minors disability functional diagnosis evaluation’s instruments ICF-CY
researchProduct

The Role of Instruments of the Common Agricultural Policy to Ensure Stability of Commercial Agricultural Holdins and Development of Rual Areas A Case…

2018

The aim of the paper is to show the role of users of commercial agricultural holdings in the development of local areas and to select instruments of the Common Agricultural Policy (CAP), which are significant in building developmental potentials of agriculture and rural areas in Opole Province. The modernization processes going on in commercial agriculture result in its de-placement. Thanks to instruments of the Common Agricultural Policy (CAP) there follows a re-rooting of agriculture in the territory. On the basis of survey research carried out in 2014 in 100 commercial agricultural holdings based in Opole Province, which were selected for the purpose, the authors present an analysis of f…

modernization of agricultural farmsintervention instruments of the CAPsustainable developmentrural areasintegrated development managementEkonomia i Środowisko
researchProduct

An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study.

2019

Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. This study aimed to assess the validity, intra-rater, and inter-rater reliability of the VeloFlex system (VS), which is a new camera-based tool designed for tracking joint trajectories and measuring joint ROM. Materials and Methods: Thirty-five healthy volunteers (16 females

musculoskeletal diseasesAdultMaleMedicine (General)AdolescentCross-sectional studyConcurrent validityeducationMesurament -- InstrumentsArticlerange of motionsymbols.namesakeYoung AdultR5-920articular goniometryHealthy volunteersMedicineHumanslower extremity; range of motion; reproducibility of results; articular goniometryRange of Motion ArticularReliability (statistics)Leg -- DiseasesOrthodonticsObserver VariationArthrometry Articularbusiness.industryOrthopedic EquipmentReproducibility of ResultsGeneral MedicineMiddle AgedPearson product-moment correlation coefficientHealthy VolunteersStandard errorCross-Sectional StudiesLower ExtremityCames -- MalaltiesGoniometersymbolsMeasuring instrumentsFemaleRange of motionbusinessMedicina (Kaunas, Lithuania)
researchProduct