Search results for " Instruments"

showing 10 items of 187 documents

Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.

2020

Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…

Dental InstrumentsHot Temperatureincidence angle0206 medical engineeringStatistical differencecutting efficiency02 engineering and technology03 medical and health sciencesReciprocating motion0302 clinical medicineNickelStatisticsMaterials TestingGeneral DentistryIncidence (geometry)MathematicsTitaniumheat treatmentIncidenceSignificant difference030206 dentistryEquipment Designreciproc blue020601 biomedical engineeringNickel titaniumHeat treatedreciprocationCalipersRoot Canal PreparationAustralian endodontic journal : the journal of the Australian Society of Endodontology IncReferences
researchProduct

Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.

2015

Objective The aim of this ex vivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Material and methods Fresh ex vivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectros…

Dental InstrumentsMaterials scienceSpectrophotometry InfraredSwinemedicine.medical_treatmentDentistryIn Vitro TechniquesOsteotomy03 medical and health sciences0302 clinical medicinemedicineAnimalsPiezosurgery030223 otorhinolaryngologyPiezosurgeryDental ImplantsDrillbusiness.industryDental Implantation Endosseous030206 dentistryDental instrumentsOsteotomyResonance frequency analysismedicine.anatomical_structureTorqueCortical boneImplantOral SurgerybusinessCancellous boneBiomedical engineeringClinical oral implants research
researchProduct

Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study

2011

The aim of this study is to evaluate if theoretically possible edge shifts induced by noise-suppression filters potentially occur on objects found in digital radiographs. Most manufacturers carry out noise-suppression filtering of their images before they are displayed to the user. It is not usually possible for the user to disrupt the function of the filters. The use of these filters can lead to deletion of small image structures.K-files (ISO size 06, 08, 10 and 15) were placed in the root canals of 6 human teeth located in cadaver jaw segments. File tip positions were measured on original and filtered digital images by three observers. The file position was marked on each filtered image a…

Dental InstrumentsRadiographyDentistryMandibleStandard deviationDigital imageCadaverEndodontic filesCadaverHumansRadiology Nuclear Medicine and imagingComputer visionGeneral DentistryMathematicsNoise suppressionPixelbusiness.industryResearchGeneral MedicineEquipment DesignRadiography Dental DigitalImage enhancementOtorhinolaryngologySubtraction TechniqueArtificial intelligenceDental Pulp CavitybusinessArtifactsFiltrationRoot Canal Preparation
researchProduct

Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization

2010

Aim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner desc…

Dental InstrumentsRoot canalDentistryMesial rootNickelClinical and Experimental DentistryMaterials TestingmedicineIrrigation SolutionsHumansStatistical analysisGeneral DentistryPreparation proceduresTitaniumbusiness.industrySterilizationElectrochemical TechniquesEquipment DesignSterilization (microbiology):CIENCIAS MÉDICAS [UNESCO]Electrochemical corrosionCorrosionmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgerybusiness
researchProduct

Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals.

2009

Objective The aim of this study was to compare the shaping ability of 4 nickel-titanium rotary techniques and 1 hand technique in simulated S-shaped curved root canals. Study design Seventy-five simulated double-curved resin root canals were divided into 5 groups (n = 15). The canals were compared at 12 different levels and at 3 different times: before preparation and after preparation to master apical 25 and 35. Data were statistically analyzed by performing 2-by-2 comparisons with the Tukey parametric test of variance analysis using a confidence interval of 95%. Results All of the 75 resin blocks presented transportation of the root canals by transforming the apical curvature into a strai…

Dental Stress AnalysisDental InstrumentsFlexibility (anatomy)Hand techniqueRoot (chord)Normal DistributionDentistryCurvatureNickelmedicineHumansTooth RootPliabilityGeneral DentistryParametric statisticsMathematicsTitaniumAnalysis of Variancebusiness.industryStructural engineeringStainless SteelModels Dentalmedicine.anatomical_structureOtorhinolaryngologyNickel titaniumSurgeryEquipment FailureOral SurgeryDental Pulp CavitybusinessRoot Canal PreparationDental AlloysOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
researchProduct

Digital holographic microscopy for diabetes screening

2016

A digital holographic microscope operating in telecentric mode could be used to diagnose diabetes and evaluate long-term glycemic control in patients with diabetes.

DiabetisMaterials sciencebusiness.industryNanotechnology02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesÒptica Aparells i instruments010309 opticsOpticsDiabetes screening0103 physical sciencesDigital holographic microscopy0210 nano-technologybusinessSPIE Newsroom
researchProduct

Appeal against the Decision on the Application for a Declaration on enforceability. Procedure to Contest the Decision Given on Appeal. Refusal or Rev…

2016

Lo scritto è un commento agli articoli da 50 a 58 del Regolamento n. 650 del 2012 del Parlamento Europeo e del Consiglio del 4 luglio 2012, relativo alla competenza, alla legge applicabile, al riconoscimento e all’esecuzione delle decisioni e all’accettazione e all’esecuzione degli atti pubblici in materia di successioni e alla creazione di un certificato successorio europeo. Lo scritto affronta i temi relativi alla impugnazione avverso la decisione emessa in seguito alla istanza per il riconoscimento delle sentenze e dei provvedimenti stranieri nelle materie oggetto del regolamento; il procedimento per impugnare le sentenza emesse in seguito all'appello; il rifiuto o la revoca del riconosc…

EU Regulation No 650/2012 on jurisdiction applicable law recognition and enforcement of decisions and acceptance and enforcement of authentic instruments in matters of succession - Decision given in a Member State - Enforceability - Procedure to Contest the Decision on EnforceabilitySettore IUS/15 - Diritto Processuale CivileRegolamento n. 650 del 2012 del Parlamento Europeo e del Consiglio del 4 luglio 2012 relativo alla competenza alla legge applicabile al riconoscimento e all’esecuzione delle decisioni in materia di successioni - Decisioni rese in altri Stati membri - Esecutività - Procedimenti per contestare la decisione emessa sulla istanza per il riconoscimento delle sentenze e dei provvedimenti stranieri
researchProduct

A DAQ-based sampling wattmeter for IEEE Std. 1459-2010 powers measurements. Uncertainty evaluation in nonsinusoidal conditions

2015

Abstract This paper presents the evaluation of the metrological performances of a DAQ-based sampling wattmeter (DAQ-SW) for the measurement of IEEE Std. 1459-2010 power quantities in non-sinusoidal conditions. The instrument makes use of two commercial data acquisition (DAQ) boards, a non-inductive current shunt, a personal computer and a commercial software for data processing. Starting from the results of an experimental characterization of the two instrument channels with non-sinusoidal voltages and currents and a correlation analysis, the combined standard uncertainties of IEEE Std. 1459-2010 quantities are evaluated, following the approach of the ISO Guide to the Expression of Uncertai…

EngineeringPC-based instrumentsHarmonic distortionlaw.inventionData acquisitionlawElectronic engineeringElectrical and Electronic EngineeringPower measurements IEEE Std. 1459-2010 Data acquisition Uncertainty Harmonic distortion PC-based instrumentsInstrumentationIEEE Std. 1459-2010Data processingTotal harmonic distortionCommercial softwarebusiness.industryApplied MathematicsElectrical engineeringUncertaintyData acquisitionWattmeterCondensed Matter PhysicsMetrologyPersonal computerMeasurement uncertaintybusinessSettore ING-INF/07 - Misure Elettriche E ElettronichePower measurements
researchProduct

Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards

2011

This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.

EngineeringVirtual instrumentElectric power measurementPC-basedlaw.inventionSet (abstract data type)Data acquisitionSampling (signal processing)lawExperimental testElectronic engineeringMeasurement theorySampled data control systemsCommercial softwareData processingpower measurements data acquisition wattmeters power system measurements sampled data systems PC-based instrumentsVirtual instrumentationData acquisition boardbusiness.industryMetrological performanceWattmeterData handlingCommercial softwareElectric powerPersonal computersSampled data systemsPower qualityPower system measurementPersonal computerHigh-accuracyInstrumentsbusinessWattmetersSettore ING-INF/07 - Misure Elettriche E Elettroniche2011 IEEE International Instrumentation and Measurement Technology Conference
researchProduct

Virtual Instruments: Uncertainty Evaluation in the Presence of Electromagnetic Interferences

2007

The electromagnetic interferences can influence the performances of a virtual instrument; consequently, in a generic measurement performed by using these instruments, the related uncertainty values can increase. In the paper, we report the results of various experimental tests performed with the aim to check if and how the radiated and/or conducted disturbances affect the instruments' characteristics and, in particular, the single uncertainty sources. Starting from these results and applying an already proposed method for the uncertainty estimation in the measurements performed by means of virtual instruments, it is possible to take into account and to evaluate the contribute of the electro…

EngineeringVirtual instrumentationbusiness.industryElectromagnetic compatibilityVirtual InstrumentsimmunityVirtual instrumentElectromagnetic interferenceData acquisitionUncertainty estimationEMCUncertainty EstimationMeasurement uncertaintyElectromagnetic ImmunitybusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheSimulationUncertainty analysis2007 IEEE International Workshop on Advanced Methods for Uncertainty Estimation in Measurement
researchProduct