Search results for " Integrated"
showing 10 items of 307 documents
The lower and middle Pleistocene geological record of the San Lorenzo lacustrine succession in the Sant’Arcangelo Basin (Southern Apennines, Italy)
2005
The Sant’Arcangelo Basin is located in the southern part of the Apennine chain (Basilicata). It is filled by a siliciclastic sequence 3500m thick, dated to the Late Pliocene–Middle Pleistocene time interval. In this basin an Early Middle Pleistocene fluvio-lacustrine sequence, known as San Lorenzo Cycle, has been recognised. In the upper part of the sequence, in Rifreddo, a fairly diversified small vertebrate assemblage has been recovered. The occurrence of Mimomys savini allows to the fauna to be considered as Biharian. The presence of some faunal elements such as Microtus (Terricola) arvalidens, Microtus (Iberomys) ex gr. huescarensis-brecciensis, and Macroneomys cf. brachygnathus restric…
Study of Beauty Hadron Decays into Pairs of Charm Hadrons
2014
First observations of the decays Λ[0 over b] → Λ[+ over c]D[− over (s)] are reported using data corresponding to an integrated luminosity of 3 fb[superscript −1] collected at 7 and 8 TeV center-of-mass energies in proton-proton collisions with the LHCb detector. In addition, the most precise measurement of the branching fraction B(B[0 over s] → D[superscript +]D[− over s]) is made and a search is performed for the decays B[0 over (s)] → Λ[+ over c]Λ[− over c]. The results obtained are B(Λ[0 over b] → Λ[+ over c]D[superscript −])/B(Λ[0 over b] → Λ[+ over c]D[− over s]) = 0.042 ± 0.003(stat) ± 0.003(syst), ⎡⎣B(Λ[0 over b] → Λ[+ over c]D[− over s]) over B([¯ over B[superscript 0] → D[superscr…
Lost in Transition: A Systematic Review of Neonatal Electroencephalography in the Delivery Room—Are We Forgetting an Important Biomarker for Newborn …
2017
Background: Electroencephalography (EEG) monitoring is routine in neonatal intensive care units (NICU) for detection of seizures, neurological monitoring of infants following perinatal asphyxia, and increasingly, following preterm delivery. EEG monitoring is not routinely commenced in the delivery room (DR). Objectives: To determine the feasibility of recording neonatal EEG in the DR, and to assess its usefulness as a marker of neurological wellbeing during immediate newborn transition. Methods: We performed a systematic stepwise search of PubMed using the following terms: infant, newborns, neonate, delivery room, afterbirth, transition and electroencephalography. Only human studies describ…
MALTA: a CMOS pixel sensor with asynchronous readout for the ATLAS High-Luminosity upgrade
2018
Radiation hard silicon sensors are required for the upgrade of the ATLAS tracking detector for the High- Luminosity Large Hadron Collider (HL-LHC) at CERN. A process modification in a standard 0.18 μm CMOS imaging technology combines small, low-capacitance electrodes (∼2 fF for the sensor) with a fully depleted active sensor volume. This results in a radiation hardness promising to meet the requirements of the ATLAS ITk outer pixel layers (1.5 × 1015 neq /cm2 ), and allows to achieve a high signal-to-noise ratio and fast signal response, as required by the HL-LHC 25 ns bunch crossing structure. The radiation hardness of the charge collection to Non-Ionizing Energy Loss (NIEL) has been previ…
An integrated calibration system for liquid argon calorimetry
1999
Abstract A novel technical solution for an integrated version of the pulse generator of a calibration system for liquid argon calorimeters is presented. It consists of a differential amplifier with automatic offset compensation, a current mirror and a switching logic. These components are integrated on an ASIC chip in CMOS technology. The technical realisation as well as results on the performance are presented.
Position sensitive scintillator based detector improvements by means of an integrated front-end
2009
PESIC is an integrated front-end for multianode photomultiplier based nuclear imaging devices. Its architecture has been designed to improve position sensitive detectors behavior by equalizing its response over its whole area. Its preamplying stage introduces two main benefits: digitally programmable gain adjustment for every photomultiplier output, and isolation from other front-end electronics by means of current buffers. This last feature allows to use different types of photomultipliers and optimizes front-end deadtime, reducing impact position dependent output delay. PESIC also includes an indirect measurement of the depth of interaction of the gamma ray inside the scintillator crystal…
The X-ray imager on AXO
2001
Abstract DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and …
Frontend electronics for high-precision single photo-electron timing using FPGA-TDCs
2014
Abstract The next generation of high-luminosity experiments requires excellent particle identification detectors which calls for Imaging Cherenkov counters with fast electronics to cope with the expected hit rates. A Barrel DIRC will be used in the central region of the Target Spectrometer of the planned PANDA experiment at FAIR. A single photo-electron timing resolution of better than 100 ps is required by the Barrel DIRC to disentangle the complicated patterns created on the image plane. R&D studies have been performed to provide a design based on the TRB3 readout using FPGA-TDCs with a precision better than 20 ps RMS and custom frontend electronics with high-bandwidth pre-amplifiers and …
Detector blockbased on arrays of 144 SiPMs and monolithic scintillators: A performane study
2015
[EN] We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12 12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured. & 2014 Elsevier B.V. All…
The CZT X-ray imager on AXO
2001
DSRI has initiated a development program of CZT X-ray and gamma ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: The X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated …