Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia
2019
PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…
Residual astigmatism produced by toric intraocular lens rotation.
2010
Purpose To analyze changes in the eye’s refractive properties when a toric intraocular lens (IOL) rotates. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Design Experimental study. Methods The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C1 and C2 whose axes form an angle a, is obtained by the addition of 2 vectors of values C1 and C2 forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part Fnes, the orth…
Correlation between optics quality of multifocal intraocular lenses and visual acuity
2009
Purpose To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the “average modulation” of the IOL was assessed. Results The pupil diameter and patient age were similar between the 3 IOL groups (20 …
Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients
2016
The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.
Modulation transfer function: Rigid versus foldable phakic intraocular lenses
2008
Purpose To study in a standard eye model the changes in modulation transfer function (MTF) of a monofocal intraocular lens (IOL) when a phakic IOL (pIOL) is placed in the anterior chamber, compare the MTFs of the rigid Artisan pIOL and foldable Artiflex pIOL, and evaluate the temporal evolution of the MTF of the foldable pIOL after the mechanical stress the pIOL undergoes when injected. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The MTF values of the IOLs were calculated from the cross-line spread function recorded with the Opal Vector System. The measurements were taken using an eye model following the British and EN-ISO standards with 2.0 mm, 3.0 mm, 4.0 mm…
The posterior chamber phakic refractive lens (PRL): a review
2012
Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…
In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.
2013
Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as …
Modulation transfer function of a toric intraocular lens: evaluation of the changes produced by rotation and tilt.
2011
PURPOSE: To evaluate the changes in optical quality when toric intraocular lenses (IOL) are rotated or tilted and to demonstrate that IOL rotation produces an increasing effect of aberrations. METHODS: Modulation transfer function (MTF) and average modulation were used to analyze the image quality of a toric IOL. The axis of the toric IOL was rotated 5°, 10°, 15°, 20°, 25°, and 30° in successive MTF measurements. The tilt values were 0° to 5°, in increments of 1°, plus a tilt of 15°. Pupil diameters of 3 and 5 mm were used. RESULTS: The MTF decay due to aberrations was more sensitive to rotation than tilt. The main decrement in the average modulation, of approximately 50% in both pupils, o…
Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.
2014
Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…
Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.
2013
Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…