Search results for " Intraocular"

showing 10 items of 215 documents

Sutureless ciliary sulcus supported intraocular lens with transiridal anchoring haptics.

2003

We report a technique for implanting intraocular lenses (IOLs) in the ciliary sulcus in eyes without capsule support. The IOL design allows it to be implanted without fixation sutures. The lens was implanted in 3 aphakic eyes without capsule support.

AdultMalemedicine.medical_specialtyCiliary sulcusgenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAphakia PostcataractProsthesis DesignFixation (surgical)Ciliary bodyLens Implantation IntraocularOphthalmologymedicineHumansAgedLenses Intraocularbusiness.industryCiliary BodySuture TechniquesCapsuleeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureIntraocular lensesSurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.

2006

ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…

AdultMalemedicine.medical_specialtyCorneal endotheliumBiometrygenetic structuresScheimpflug principleIrisAnterior surfacePhakic intraocular lensRefraction Ocularlaw.inventionLens Implantation IntraocularlawAnterior Eye SegmentCorneaOphthalmologyLens CrystallinemedicineMyopiaPhotographyHumansIris (anatomy)Retrospective StudiesLenses Intraocularbusiness.industrySuture Techniqueseye diseasesLens (optics)Ophthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Effects of intraocular cefotaxime on the human corneal endothelium

2001

Abstract Purpose To ascertain whether 0.4 mL of cefotaxime 0.25% applied intracamerally causes toxic alteration of the human corneal endothelium. Methods In this prospective randomized masked study, 66 patients had cataract extraction using phacoemulsification, a frown incision, and implantation of a poly(methyl methacrylate) intraocular lens. This was followed by intraocular injection of 0.4 mL of cefotaxime 0.25% or balanced salt solution (BSS®). Contact specular microscopy and photography were performed preoperatively and 1 to 4 days and 3 months postoperatively. Results In the cefotaxime group, the mean endothelial cell count was 2729 cells/mm 2 ± 474 (SD) preoperatively, 2520 ± 462 cel…

AdultMalemedicine.medical_specialtyCorneal endotheliumCefotaximeAnterior Chambermedicine.medical_treatmentCell CountIntraocular lensBalanced salt solutionCefotaximeDouble-Blind MethodLens Implantation IntraocularCorneaOphthalmologymedicineHumansProspective StudiesAgedCell SizeAntibacterial agentAged 80 and overEndophthalmitisPhacoemulsificationbusiness.industryEndothelium CornealPhacoemulsificationMiddle AgedSensory SystemsCephalosporinsEndothelial stem cellOphthalmologymedicine.anatomical_structureFemaleSurgerysense organsbusinessmedicine.drugJournal of Cataract and Refractive Surgery
researchProduct

Refractive lens exchange with an array multifocal intraocular lens.

2002

ABSTRACT PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeRefraction Ocularlaw.inventionPostoperative ComplicationsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansProspective StudiesIntraocular PressureLenses IntraocularClear lens extractionbusiness.industryMultifocal intraocular lensMiddle AgedRefractioneye diseasesSurgeryLens (optics)OphthalmologyHyperopiaTreatment OutcomePatient SatisfactionSurgeryFemalesense organsmedicine.symptomSafetybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Iris-fixated toric phakic intraocular lens: Three-year follow-up

2006

Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAstigmatismRefraction OcularPhakic intraocular lensOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineHumansMedicineProspective StudiesIntraoperative ComplicationsIntraocular PressureDioptremedicine.diagnostic_testbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresOphthalmoscopyToric lensOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Retinal Imaging through Phakic Iris-Claw IOL.

2014

AbstractBackground: Phakic anterior chamber iris-fixated IOL (PIOL) are established for the correction of high myopia. These patients require attention to macular pathologies. This study was to evaluate the quality of imaging through the PIOLs. Methods: 54 eyes of 31 myopic and hyperopic patients with Verisyse®, Verisyse toric®, and Veriflex® phakic iris-fixated IOL were included. Mean preoperative refraction was −11.0 D and +5.7 D, respectively; mean follow-up time was 7.4 years (5–11 years). A matched control group was formed without PIOL implantation. OCT scans were performed and evaluated qualitatively and quantitatively. Results: In 52 eyes of 31 patients (96%), a 3D-OCT image and fund…

AdultMalemedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresAnterior ChamberVisual AcuityIrisFoveal thicknessFundus (eye)Refraction OcularRetinaImaging Three-DimensionalLens Implantation IntraocularOphthalmologymedicineMyopiaHumansPhakic iolIris clawmedicine.diagnostic_testbusiness.industrySignificant differenceFundus photographyHigh myopiaGeneral MedicineMiddle Agedeye diseasesOphthalmologyHyperopiaRetinal imagingFemalesense organsbusinessTomography Optical CoherenceFollow-Up StudiesSeminars in ophthalmology
researchProduct

Inflammation after sclerocorneal versus clear corneal tunnel phacoemulsification.

2000

Abstract Objective To compare the postoperative inflammation after phacoemulsification followed by intraocular lens (IOL) implantation by means of sclerocorneal versus clear corneal tunnel incision. Design Randomized controlled clinical trial. Participants One hundred eyes of 100 patients were examined at a German University eye hospital. Intervention One hundred eyes with cataract necessitating phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision by a single surgeon. Main outcome measures Preoperative and postoperative inflammation was evaluated by measurement of flare using laser flare photo…

AdultMalemedicine.medical_specialtyRandomizationBlood-Aqueous Barriergenetic structuresAnterior Chambermedicine.medical_treatmentEye diseaseVisual AcuityIntraocular lensRefraction OcularFluorophotometryCorneaLens Implantation IntraocularCorneaOphthalmologyMedicineHumansProspective StudiesSclerocorneaIntraocular PressureAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedmedicine.diseaseUveitis Anterioreye diseasesSurgeryOphthalmologymedicine.anatomical_structureFemalesense organsPostoperative inflammationbusinessSurgical incisionScleraOphthalmology
researchProduct

Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction.

2013

Purpose To evaluate the efficacy, predictability, safety, and stability of a new-model posterior chamber Implantable Collamer Lens phakic intraocular lens (pIOL) (V4c Visian) to correct myopia. Setting Private practice, Oviedo, Spain. Design Case series. Methods This study enrolled patients who had implantation of a new pIOL design with a central hole for more natural aqueous flow, eliminating the need for neodymium:YAG iridotomy or peripheral iridectomy. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refractive error, intraocular pressure (IOP), endothelial cell count, central vault, and adverse events were evaluated 6 months postoperatively. Results The study enroll…

AdultMalemedicine.medical_specialtyRefractive errorIntraocular pressurePhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityCell CountPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineMyopiaHumansProspective StudiesProspective cohort studyDioptreIntraocular PressureAqueous flowbusiness.industryEndothelium CornealCorneal Endothelial Cell Lossmedicine.diseaseRefractive Errorseye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomePrivate practiceIridectomySurgeryFemalesense organsCollagenbusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Endothelial cell loss after toric iris-fixated phakic intraocular lens implantation: three-year follow-up.

2007

ABSTRACT PURPOSE: To study quantitative changes in endothelial cell count after implantation of the toric iris-fixated phakic intraocular lens. METHODS: A prospective, non-randomized, self-controlled clinical trial was conducted of 40 eyes (28 myopic, 12 hyperopic) of 23 patients with high ametropia and astigmatism. Non-contact computer-assisted endothelial microscopy was performed before and I1 2, and 3 years after surgery. RESULTS: In the myopic group, mean preoperative endothelial cell count was 3179±531 cells/mm p 2 (range: 1800 to 3900 cells/mm2). The mean intraindividual endothelial cell loss was -1.83±2.25% (range: -9.09% to 0%) in the first year; -1.83+2.95% (range: -7.74% to 3.80%)…

AdultMalemedicine.medical_specialtyTime FactorsIrisCell CountAstigmatismPhakic intraocular lensEndothelial cell countCorneal DiseasesPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineMedicineHumansProspective Studiesbusiness.industryEndothelium CornealSuture TechniquesMiddle Agedmedicine.diseaseCell lossRefractive Surgical ProceduresEndothelial stem cellOphthalmologySurgeryFemalebusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.

2009

PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…

AdultMalemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectProsthesis DesignRefraction OcularSeverity of Illness IndexContrast Sensitivity03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularMonocularbusiness.industryGeneral MedicineMultifocal intraocular lensMiddle AgedDistance correctioneye diseasesOphthalmologyTreatment Outcome030221 ophthalmology & optometryFemalesense organsSpatial frequencymedicine.symptombusiness030217 neurology & neurosurgeryPhotopic visionEuropean journal of ophthalmology
researchProduct