Search results for " Intraocular"

showing 10 items of 215 documents

Efficacy and safety study of an eyelid gel after repeated nocturnal application in healthy contact lens users and non-users

2020

Purpose: To evaluate skin biocompatibility of a nighttime hydrating eyelid gel and possible ocular surface effects in contact lens users (CLU) and non-contact lens users (NCLU). The formulation is registered as a medical device as Tridocosahexaenoine-AOX® (TDHA-AOX) (a concentrated DHA triglyceride), containing also hyaluronic acid (HA). Methods: A prospective, randomized, masked clinical trial was performed with 62 participants of both sexes, aged 20–70 years, split into: (1) CLU (n = 30) and (2) NCLU (n = 32). All participants were instructed to apply a single dose of the moisturizing gel (containing TDHA-AOX and HA) nightly to the upper and inner eyelids of their right eye (RE) only, and…

DHA docosahexaenoic acidNon usersFBUT fluorescein break-up timeALA alpha linolenic acidTDAH-AOX tridocosahexaenoin-antioxidantNCLU non contact lens users0302 clinical medicineLC PUFAs long chain polyunsaturated fatty acidsMedicineCL contact lensesOS ocular surfaceHA hyaluronic acidOSDI ocular surface disease indexDE dry eyeCLU contact lens usersCLDEQ contact lens dry eye questionnaireVEGF vascular endothelial growth factorDocosahexaenoic acidBMC biomicroscopymedicine.anatomical_structureMedicamentosCytokinesOftalmologíaOriginal ArticleBCVA best corrected visual acuitymedicine.medical_specialtyOcular surface dysfunctionCorneal stainingContact LensesHyaluronic acidRE right eyeDEs dry eye syndrome03 medical and health sciencesOphthalmologyHumansAdverse effectbusiness.industryEyelidsEPA eicosapentaenoic acidAnatomía ocularIOP intraocular pressureeye diseasesClinical trialContact lensMOISTURIZING GEL030221 ophthalmology & optometryTearsLE left eyeEyelidsense organsbusiness030217 neurology & neurosurgeryOptometry
researchProduct

Fractal-structured multifocal intraocular lens

2017

[EN] In this work, we present a new concept of IOL design inspired by the demonstrated properties of reduced chromatic aberration and extended depth of focus of Fractal zone plates. A detailed description of a proof of concept IOL is provided. The result was numerically characterized, and fabricated by lathe turning. The prototype was tested in vitro using dedicated optical system and software. The theoretical Point Spread Function along the optical axis, computed for several wavelengths, showed that for each wavelength, the IOL produces two main foci surrounded by numerous secondary foci that partially overlap each other for different wavelengths. The result is that both, the near focus an…

DiffractionOptical PhenomenaFocus (geometry)VisionSocial Scienceslcsh:MedicinePhysics::Optics01 natural sciences0302 clinical medicineMedicine and Health SciencesPsychologylcsh:ScienceLens (Anatomy)PhysicsMultidisciplinaryPhysicsOphthalmic ProceduresCataract SurgeryOptical LensesWavelengthFractalsOptical EquipmentPhysical SciencesEngineering and TechnologySensory PerceptionAnatomyDiffractionResearch ArticlePoint spread functionOcular AnatomyGeometryEquipmentSurgical and Invasive Medical ProceduresIn Vitro TechniquesProsthesis DesignProof of Concept Study010309 optics03 medical and health sciencesFractalOpticsOcular SystemOptical transfer function0103 physical sciencesChromatic aberrationPrototypesComputer Simulationbusiness.industrylcsh:RBiology and Life SciencesModels TheoreticalMultifocal Intraocular LensesOptical axisTechnology DevelopmentFISICA APLICADAWaves030221 ophthalmology & optometryEyeslcsh:QbusinessHeadMathematicsNeuroscience
researchProduct

Ophthalmic: Laboratorio virtual para el diseño de nuevas lentes oftálmicas

2013

This work presents a new virtual laboratory, OPHTALMIC, developed with MATLAB GUI for using in Optics and Optometry courses as a computer tool for studying the focusing properties of multifocal diffractive both on unconventional structures both periodic and aperiodic. This virtual laboratory enables students to quickly and easily analyze the influence of the different parameters of construction and find the best solution for a user.

Engineering drawingEngineeringComputer toolsbusiness.industryCantor setOptical qualitylcsh:Education (General)Multifocal intraocular lensAperiodic graphVirtual LaboratoryMATLABbusinesslcsh:L7-991computercomputer.programming_languageModelling in Science Education and Learning
researchProduct

Material properties of various intraocular lenses in an experimental study.

2002

<i>Introduction:</i> With the recent introduction of small-incision cataract surgery, requirements for intraocular lens (IOL) flexibility, strength and hydrophilicity have rapidly evolved. The IOL surface, however, remains a critical factor influencing uveal biocompatibility. <i>Purpose:</i> To objectively quantify factors of material properties of various IOLs using contact angle measurements, differential scanning calorimetry, dynamic-mechanical measurements and scanning electron microscopy. <i>Material and Methods:</i> In our study, 17 currently available IOLs were investigated using contact angle measurements to assess hydrophilicity and biocompatibil…

Flexibility (engineering)Lenses Intraocularmedicine.medical_specialtygenetic structuresCalorimetry Differential ScanningComputer sciencemedicine.medical_treatmentSiliconesIntraocular lensGeneral MedicineEquipment DesignCataract surgeryeye diseasesSensory SystemsElasticityHydrogel Polyethylene Glycol DimethacrylateOphthalmologyIntraocular lensesAcrylatesOphthalmologymedicineMicroscopy Electron ScanningHumanssense organsOphthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde
researchProduct

Sensibilidad al contraste tras cirugía de cristalino transparente con lente intraocular multifocal asférica difractiva

2013

PURPOSE: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model) intraocular lens (IOL). METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively) were measured before and 6 months postoperatively. Monocular CS function was measured at t…

HiperopiaHyperopiaPhacoemulsificationVisual acuityMiopíaLens implantation intraocularImplantación de lentes intraocularesMyopiaAgudeza visualLens cristallineCristalinoFacoemulsificación
researchProduct

Visual and optical performance with hybrid multifocal intraocular lenses

2010

During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…

Intraocular LensesOptical PerformanceVisual acuitygenetic structuresCompensation Comparisonmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMethodKeratomileusislaw.inventionGlareLensTratamiento médicoSensitivitylawRefractive surgeryMedicineContrast (vision)MonovisionPostoperative Periodmedia_commonVistaLenses IntraocularMultifocalsGlare (vision)Equipment DesignRefractive ErrorsLens (optics)Bilateral ImplantationApodized Diffractive IolOftalmologíamedicine.symptommedicine.medical_specialtyIn-Situ KeratomileusisRefractivemedia_common.quotation_subjectHigh-Order AberrationsContrast SensitivityOphthalmologyAberrometryClinical-OutcomesHumansRetinal StraylightDepth Perceptionbusiness.industryAberrometryMultifocal intraocular lensContrasteye diseasesOphthalmologyOptometrysense organsbusinessOptometry
researchProduct

miRNAs and Genes Involved in the Interplay between Ocular Hypertension and Primary Open-Angle Glaucoma. Oxidative Stress, Inflammation, and Apoptosis…

2021

Este artículo se encuentra disponible en la siguiente URL: https://www.mdpi.com/2077-0383/10/11/2227 En esta investigación también participan: Mar Valero Vello, Silvia M. Sanz González, José E. O'Connor, David Galarreta Mira, María D. Pinazo-Durán y Vicente Zanón Moreno. Este artículo pertenece al número especial "Recent Clinical Research on Glaucoma". Glaucoma has no cure and is a sight-threatening neurodegenerative disease affecting more than 100 million people worldwide, with primary open angle glaucoma (POAG) being the most globally prevalent glaucoma clinical type. Regulation of gene expression and gene networks, and its multifactorial pathways involved in glaucoma disease are landmark…

Intraocular pressureBiochemical markers.Open angle glaucomagenetic structuresGlaucomaOcular hypertensionDiseaseBioinformaticsArticle03 medical and health sciences0302 clinical medicineGene expressionmicroRNAApoptosis.Medicineoxidative stressGlaucoma.genes030304 developmental biologyRegulation of gene expressionEstrés oxidativo.next generation sequencing0303 health sciencesbusiness.industryPresión intraocular.apoptosisneurodegenerationIntraocular pressure.RMarcadores bioquímicos.tearsbiomarkersGeneral Medicinemedicine.diseasesignaling pathwayseye diseasesOxidative stress.glaucomainflammationmiRNAs030221 ophthalmology & optometryocular hypertensionMedicinebusinessJournal of Clinical Medicine
researchProduct

Do Age and Sex Play a Role in the Intraocular Pressure Changes after Acrobatic Gymnastics?

2021

To evaluate the effects of an acrobatic gymnastics (AG) training session on intraocular pressure (IOP), a familiarization session was employed to confirm the participant’s suitability for the study. Forty-nine gymnasts (63.27% females, 18–40 years old) voluntarily agreed to participate. As age, sex, baseline IOP, and central corneal thickness (CCT) were considered as potential predictors of the IOP variations, in the second session measurements of the above parameters were taken before and after 90 min of AG. A mixed-factorial analysis of variance evaluated differences. Linear regression was conducted to potentially predict the IOP variation with the exercise. After the scheduled exercise, …

Intraocular pressuremedicine.medical_specialtyOcular healthgenetic structuresocular healthbaseline intraocular pressureGlaucomaPhysical exerciseAge and sexArticlephysical exerciseOphthalmologytumbling skillsacrobatic gymnasticsMedicinebusiness.industryRhand balanceGeneral Medicinemedicine.diseaseeye diseasesMedicinecentral corneal thicknessAnalysis of variancesense organsbusinesssportJournal of Clinical Medicine
researchProduct

Large diurnal variation of intraocular pressure in open angle glaucoma in subjects with type A behaviour pattern

2014

Aim : To evaluate the possible causes of the greater perimetric damage found in OAG subjects with type A behaviour and the possible role of psycho-physiological stress. Materials and methods : 80 patients with OAG, 44 women and 36 men, 40 with type A behaviour and 40 with type B studied with the Type A/B Personality Questionnaire (A modified version of the Jenkins Activity Survey), underwent a complete ophthalmologic examination consisting of bio-microscopy, tonometry and daily tonometric curve, examination of the visual field by means of Octopus 1-2-3 computerised perimeter and its assessment with the Glaucoma Staging System 2 (GSS2), morphological monitoring of the Retinal Nerve Fibre Lay…

Intraocular pressuremedicine.medical_specialtyOpen angle glaucomabusiness.industrySettore MED/30 - Malattie Apparato VisivoeducationDiurnal temperature variationType A behaviour patternhumanitiesStress (mechanics)Blood pressureOphthalmologyType a behaviour pattern open angle glaucoma intraocular pressure perimetric damage arterial pressureOptometryMedicinebusiness
researchProduct

Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

2009

Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …

Laser surgeryAdultMaleRefractive errormedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensCell CountAstigmatismPhakic intraocular lensSafety indexPostoperative ComplicationsLens Implantation IntraocularRefractive surgeryOphthalmologymedicineMyopiaHumansProspective StudiesDioptrebusiness.industryEndothelium CornealAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment OutcomeSurgeryFemalesense organsbusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct