Cascaded Multilevel Inverter-Based Asymmetric Static Synchronous Compensator of Reactive Power
2022
The topology of the static synchronous compensator of reactive power for a low-voltage three-phase utility grid capable of asymmetric reactive power compensation in grid phases has been proposed and analysed. It is implemented using separate, independent cascaded H-bridge multilevel inverters for each phase. Every inverter includes two H-bridge cascades. The first cascade operating at grid frequency is implemented using thyristors, and the second one—operating at high frequency is based on the high-speed MOSFET transistors. The investigation shows that the proposed compensator is able to compensate the reactive power in a low-voltage three-phase grid when phases are loaded by highly asymmet…
Reliability Analysis of Three Homogeneous Fault-tolerant Inverter Topologies
2016
Abstract—In this article, non-redundant fault-tolerant inverter topologies are addressed. A novel fault-tolerant control strategy which enhances performances during post-fault operation is proposed. Benefits from the proposed strategy over conventional fault-tolerant topologies are investigated in terms of system reliability. Cost, post-fault performances, and system reliability of the proposed solution are compared with both a conventional triac-based fault-tolerant inverter and a T-type inverter. The reliability analysis of each selected configuration is carried out by means of Markov chains. The analysis is validated through a comparison of reliability and sensitivity curves. As shown by…
Investigation about selective harmonic elimination in unbalanced multilevel inverters
2022
In this paper 5 and 7 levels cascaded H-bridges inverters are considered, feeding by unequal dc voltage sources. The effect of these unbalancing operation is examined concerning harmonic analysis and total harmonic distortion of the output voltages. The system of equations, obtained by the expansion in the Fourier series of phase output voltage, is solved by applying a method of graphic solution that allows obtaining the switching angles able to eliminate the lower order harmonics.
Extending the Power Range of a Solar Inverter
2018
Solar inverters feature a minimum and maximum limit of the maximum power point voltage. Overcoming these limits leads to a disconnection of the power equipment, thus wasting the solar energy. In this paper, a solution to extend the power range of a solar inverter is presented. The proposed solution extends he minimum maximum power point limit of a commercial solar inverter by means of a battery energy storage system, including a DC/DC power converter. The battery energy storage system is connected in series to the photovoltaic module. If the photovoltaic module voltage drops below the minimum maximum power point limit, the battery energy storage system is enabled thus boosting the input vol…
Impact Evaluation of Innovative Selective Harmonic Mitigation Algorithm for Cascaded H-Bridge Inverter on IPMSM Drive Application
2021
This paper presents a detailed analysis of the use of a novel Harmonic Mitigation algorithm for Cascaded H-Bridge Multilevel Inverter in electrical drives for the transportation field. For this purpose, an enhanced mathematical model of Interior Permanent Magnet Synchronous Motor (IPMSM), that takes into account simultaneously saturation, cross-coupling, spatial harmonics, and iron loss effects, has been used. In detail, this model allows estimating accurately the efficiency and the torque ripple of the IPMSM, crucial parameters for transportation applications. Moreover, two traditional pulse width modulation strategies, Sinusoidal Phase-Shifted and Switching Frequency Optimal Phase-Shifted…
Experimental Validation of Maximum Constant Boost Control and Switching Frequency Optimal for three-phase Quasi-Z-Source Converters
2020
This paper presents a modified modulation scheme for quasi-Z-Source converters, based on the Maximum Constant Boost Control (MCBC) concept and Switching Frequency Optimal (SFO) as reference signal. The effectiveness of the proposed technique is validated by comparing the obtained results (in terms of AC harmonic content and voltage stress) with those carried out from traditional modulation schemes. For this reason, a test bench has been assembled and the benefits of the SFO MCBC modulation scheme have been valuated.
Decoupled control scheme of grid-connected split-source inverters
2017
Grid-connected power conversion systems for renewable energy sources must fulfill several requirements, e.g., the high efficiency, the reduced cost and complexity, and, quite often, the boost capabilities that is usually achieved using a front-end dc–dc boost converter before the inversion stage, leading to a two-stage architecture. Meanwhile, single-stage power conversion systems, which perform the boosting operation within the inversion one, offer some potential advantages, in terms of reducing the complexity and the volume of the whole system. Among several proposed options, the split-source inverter (SSI) has been recently proposed by Abdelhakim et al. as an alternative option with some…