Search results for " Lens"
showing 10 items of 510 documents
Power profiles in multifocal contact lenses with variable multifocal zone
2016
BACKGROUND The power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. METHODS The measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a functi…
Conservation of optical purity of amino acids: a principal problem in biochemical and proto-biochemical systems.
1981
Dor L-amino acids, regardless of their state (peptide-bound or free, in the solid state or in aqueous solution), tend to racemize. In a living cell this racemization is usually compensated by specific degradation and replacement of the unwanted polypeptides that contain the wrong enantiomers. But a few long-lived proteins that are synthesized at or near birth are never replaced. Well investigated is the racemization of L-aspartic acid at a rate of 0.1 to 1.14 per cent per year in proteins from lenses and dentine. Increased racemization of eye lens proteins has been related to a form of human eye disease known as brunescent cataracts. Also quite well investigated is the racemization of amino…
Oxygen permeability of hydrogel contact lenses with organosilicon moieties
2002
Oxygen transport through two extended wear (day and night) hydrogel contact lenses that contain organosilicon moieties (balafilcon A and lotrafilcon A) was studied in the hydrate (hydrogel) and dry (xerogel) states. The water uptake increased the oxygen permeability [(Dk)app] and transmissibility [Dk/L(av)] coefficients of the dry materials by about 70%. The (Dk)app for the hydrated lenses was determined following the so-called stack procedure. The values obtained were 107 +/- 4 barrer for balafilcon A and 141 +/- 5 barrer for lotrafilcon A, about 5-10 times larger than those previously reported for conventional (without organosilicon moieties) extended wear hydrogels contact lenses. The Dk…
Power Profiles and In Vitro Optical Quality of Scleral Contact Lenses: Effect of the Aperture and Power
2017
To assess the power profile and in vitro optical quality of scleral contact lenses with different powers as a function of the optical aperture. The mini and semiscleral contact lenses (Procornea) were measured for five powers per design. The NIMO TR-1504 (Lambda-X) was used to assess the power profile and Zernike coefficients of each contact lens. Ten measurements per lens were taken at 3- and 6-mm apertures. Furthermore, the optical quality of each lens was described in Zernike coefficients, modulation transfer function, and point spread function (PSF). A convolution of each lens PSF with an eye-chart image was also computed. The optical power fluctuated less than 0.5 diopters (D) along th…
Optical quality of rotationally symmetrical contact lenses derived from their power profiles.
2017
To present a methodology for evaluating the optical quality of rotationally symmetrical contact lenses (CLs) from a single power profile.Simulated rotationally symmetrical power profiles corresponding to different CLs designs (monofocal, two-zone center-near bifocal, and four-zone center-distance bifocal) were used to calculate the wavefront error profile by means of numerical integration. Then, each lens wavefront error profile was spun around the center to obtain the lens wavefront error surface. From the surface, monochromatic optical transfer functions (OTF), simulated images and the visual Strehl ratio based on the OTF (VSOTF) were obtained for different distances and pupil sizes (3 an…
In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.
2015
Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…
Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering
2012
To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…
Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.
2016
Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…
Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia
2019
PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…
Residual astigmatism produced by toric intraocular lens rotation.
2010
Purpose To analyze changes in the eye’s refractive properties when a toric intraocular lens (IOL) rotates. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Design Experimental study. Methods The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C1 and C2 whose axes form an angle a, is obtained by the addition of 2 vectors of values C1 and C2 forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part Fnes, the orth…