Search results for " Lens"
showing 10 items of 510 documents
Diffractive multifocal intraocular lenses: reading performance and quality of life evaluation
2011
ABSTRACT Purpose: To evaluate the reading performance and changes in quality of life after cataract surgery with multifocal diffractive (IOLs) implantation Setting: Section of Ophthalmology - Department of Experimental Biomedicine and Clinical Neuroscience, University of Palermo, Italy; Eye Clinic - Department of Preclinical and Clinical Pharmacology, University of Florence, Italy. Methods: 160 Consecutive eyes of cataract patients were divided into two groups. One group (20 patients, 40 eyes) received aspheric monofocal IOLs (Acrysof SN60WF). One group (60 patients, 120 eyes) was implanted with a diffractive aspheric multifocal IOL produced by different manufacturers: 20 patients with Acry…
3D digitization of transparent objects by polalization techniques in IR & by triangulation in UV
2011
Two non-conventional methods for the 3D digitization of transparent objects via non-contact measurement are reported in this thesis. 3D digitization is a well acknowledged technique for opaque objects and various commercial solutions based on different measurement approaches are available in the market offering different types of resolution at different prices. Since these techniques require a diffused or lambertian surface, their application to transparent surfaces fails. Indeed, rays reflected by the transparent surface are perturbed by diverse inter-reflections induced by the refractive properties of the object. Therefore, in industrial applications like quality control, the transparent …
The effect of fractal contact lenses on peripheral refraction in myopic model eyes.
2014
Purpose: To test multizone contact lenses in model eyes: Fractal Contact Lenses (FCLs), designed to induce myopic peripheral refractive error (PRE). Methods: Zemax ray-tracing software was employed to simulate myopic and accommodation-dependent model eyes fitted with FCLs. PRE, defined in terms of mean sphere M and 90–180 astigmatism J180, was computed at different peripheral positions, ranging from 0 to 35 in steps of 5, and for different pupil diameters (PDs). Simulated visual performance and changes in the PRE were also analyzed for contact lens decentration and model eye accommodation. For comparison purposes, the same simulations were performed with another commercially available conta…
Phake Intraokularlinsen
2004
Phakic intraocular lenses (PIOLs), which are located closer to the eye's nodal points than the anterior corneal surface, can provide superior optical quality for higher corrections because of retention of normal prolate corneal asphericity and larger effective optical zones. Improvements in the material and design of phakic intraocular lenses and their insertion devices combined with advances in the understanding of the anatomical and physiological interactions of the PIOLs with intraocular structures, have increased safety and efficacy. Safety of these implants over the long term remains a concern, but in several situations PIOLs are the refractive correction of choice. The purpose of this…
Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism.
2020
Aim To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with low degrees of corneal astigmatism. Methods Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL (FineVision PODFT, PhysIOL s.a., Liege, Belgium) were enrolled. Phacoemulsification with femtosecond laser, capsular tension ring insertion and intraoperative aberrometry were performed in all cases. All IOLs used showed a cylinder power of 1.00 D. Main outcome measures were refractive error and corrected-distance visual acuity (CDVA) and uncorrected-distance visual acuity (UDVA) values. Eyes were evaluated at 4mo post-su…
Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes
2008
Contrast Test chart at distance and near under 3 luminance levels (85.0 cd/m 2 , 5.0 cd/m 2 , and 2.5 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR IOL implantation in 30 hyperopic eyes with presbyopia and low astigmatism (%1.0 diopter). Results after surgery were compared with those before surgery. RESULTS: Six months postoperatively, the mean residual spherical equivalent refractive error was 0.21 diopter G 0.19 (SD). The best corrected distance and near visual acuities were comparable to those before surgery. For distance vision, the safety index was 1.02 and the efficacy index was 0.91. For near vision, the values were 1.04 and 1.02, respectively. There were no statistical…
Surgical management of acute angle-closure glaucoma after toric implantable contact lens implantation
2006
A case of pupillary block after implantation of an implantable contact lens (ICL) is reported, and surgical management and prevention are discussed. In a myopic patient, the best corrected visual acuity in the right eye was 20/50 with -15.50 -3.00 x 175. After uneventful implantation of an ICL, painful acute glaucoma developed with an intraocular pressure beyond measurable values. Apparent anterior vaulting of the ICL suggested a sizing problem. In a situation of a mid-wide dilated pupil, immediate explantation of the ICL was performed. Then, using a preoperative iris photography as guidance, an anterior chamber iris-claw toric phakic intraocular lens was implanted. On postoperative examina…
Images perceived after chromatic or achromatic contrast sensitivity losses.
2010
Purpose. We simulate how subjects with losses in chromatic and achromatic contrast sensitivity perceive colored images by using the spatiochromatic corresponding pair algorithm. Methods. This is a generalized version of the algorithm by Capilla et al. (J Opt Soc Am (A) 2004;21:176 –186) for simulating color perception of color deviant subjects, which incorporates a simple spatial vision model, consisting of a linear filtering stage, with a band-pass achromatic filter and two low-pass chromatic ones, for the red-green and blue-yellow mechanisms. These filters, except for the global scaling, are the subject’s contrast sensitivity functions measured along the cardinal directions of the color s…
Intraocular lens centration and stability: efficacy of current technique and technology
2008
Purpose of review The manuscript presents a review of recently published studies analyzing different methodologies to assess centration and stability of intraocular lenses after implantation. Recent findings Considering that there is no current gold standard for centration and stability of intraocular lenses after implantation, we have summarized the different techniques used clinically for intraocular lenses centration and stability estimation. We have described the use of Scheimpflug imaging, the anterior segment optical coherence tomography and photography analysis used for lens position estimation. Techniques used to assess lens rotation are based on image analysis on digital retroillum…
Radon–Wigner display: a compact optical implementation with a single varifocal lens
2008
A new optical implementation of the Radon‐Wigner display for one-dimensional objects is presented, making use of the fractional Fourier transform approach. The proposed setup makes use of only two conventional refractive elements: a cylindrical lens and a varifocal lens. Although the exact magnifications cannot be achieved simultaneously for all the fractional transforms, an optimum design can be obtained through balancing the conflicting magnification requirements. Experimental results are obtained with a commercially available progressive addition lens. For comparison, computer simulations are also provided. © 1997 Optical Society of America