Search results for " Lens"
showing 10 items of 510 documents
Validation of a spectral light scattering method to differentiate large from small particles in intraocular lenses
2017
A psychophysical approach has been designed to measure straylight from intraocular lenses (IOLs) in vitro. This approach uses a clinical straylight meter (C-Quant) and an observer's eye as optical detector. Based on this, we introduced a method for study of straylight-wavelength dependency for IOLs. This dependency can be used to distinguish between 2 types of scattering particles (small and large) as defined by Mie theory. Validation was performed using a turbidity standard and scattering filters. Several IOLs were analyzed to identify potential scattering sources. Large particles were found to predominate in scattering from the studied lenses. This was confirmed by straylight-angular depe…
Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses. results of a multicenter questionnaire.
2001
Abstract Purpose To compare the incidence and severity of photic phenomena after the implantation of the Array® (Allergan) refractive multifocal intraocular lens (MIOL) and a monofocal IOL. Setting Multicenter study at Kiel, Mainz, Karlsruhe, and Bremerhaven, Germany. Methods The study comprised 231 randomly selected patients from 4 study centers. The patients had had uneventful phacoemulsification with implantation of a refractive MIOL (n = 138) or a monofocal IOL (n = 93). By questionnaire, patients were asked whether they experienced light sensations postoperatively (light streaks, halos, flare, flashes, or glare) that had not been noticed preoperatively. Additional questions evaluated w…
Color stimuli perception in presence of light scattering.
2006
Perception of different color contrast stimuli was studied in the presence of light scattering: in a fog chamber in Clermont-Ferrand and in laboratory conditions where light scattering of similar levels was obtained, using different light scattering eye occluders. Blue (shortest wavelength) light is scattered in fog to the greatest extent, causing deterioration of vision quality especially for the monochromatic blue stimuli. However, for the color stimuli presented on a white background, visual acuity in fog for blue Landolt-C optotypes was higher than for red and green optotypes on the white background. The luminance of color Landolt-C optotypes presented on a LCD screen was chosen corresp…
Modulation transfer function in refractive-diffractive multifocal intraocular lenses in vitro
2007
Purpose: The optical quality of two types of multifocal, hybrid refractive-diffractive, intraocular lenses (IOL) is analyzed in vitro. Following the EN-ISO international standard, the IOLs’ modulation transfer functions (MTF) are determined for both distance and near vision. The behaviour of these curves when the pupil size varies is studied. Methods: The IOLs analyzed were: AcrySoft ResTor SN60D3 (Alcon) and Tecnis ZM900 (AMO). The MTF was calculated from the cross line-spread function recorded with the OPAL Vector System (Image Science Ltd. Oxford) by using fast Fourier transform techniques. The artificial eye model used simulates in vivo conditions of the anterior chamber including an ar…
Contrast sensitivity perimetry tests along the cardinal directions in color space: Correlation with the properties of the neural mechanisms mediating…
2014
It is well-known the advantages of measuring chromatic and achromatic contrast sensitivity for detecting pathologies. But these measurements are rarely used in clinical practice, due the complexity of the measurements and the examinator specialization. In fact, there is not a complete characterization of the response of the visual pathways to achromatic and chromatic spatio-temporal frequency stimuli. We have designed a new experimental device that facilitates these measurements and allow us to characterize the visual response in healthy patients. In this paper, we evaluated the responses of the visual pathways in healthy patients.
Multispectral analysis and cone signal modelling of pseudoisochromatic test plates
2013
The aim of the study is to determine the consistency of the desired colour reproduction of the stimuli using calibrated printing technology available to anyone (EpsonStylus Pro 7800 printer was). 24 colour vision assessment plates created in the University of Latvia were analysed right after their fabrication on august 2012 and after intense use for 7 months (colour vision screening on 700 people). Multispectral imagery results indicate that the alignment of the samples after seven months of use has maintained on the CIExy confusion lines of deutan deficiency type, but the shift towards achromatic area in the diagram indicate decrease in the total colour difference (ΔE*ab) of test backgroun…
Estimation of the mechanical properties of the eye through the study of its vibrational modes.
2017
Measuring the eye's mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral a…
Multifokale Intraokularlinsen
2001
Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of tha…
Binocular vision alterations after refractive and cataract surgery: a review.
2018
To review binocular and accommodative disorders documented after corneal or intraocular refractive surgery, in normal healthy prepresbyopic patients. A bibliographic revision was performed; it included works published before 1st July 2017 where accommodation and/or binocularity was assessed following any type of refractive surgical procedure. The search in Pubmed yielded 1273 papers, 95 of which fulfilled the inclusion criteria. Few publications reporting binocular vision and/or accommodative changes after refractive surgery in normal subjects were found. The reduction in fusional vergence is the most frequently reported alteration. Anisometropia is an important risk factor for postoperativ…
Spectroscopic capture of 1 Hz volcanic SO2fluxes and integration with volcano geophysical data
2009
[1] Here we present a novel spectroscopic approach to capturing, with unprecedented time resolution and accuracy, volcanic SO2 fluxes. This is based on two USB2000 spectrometers, coupled to cylindrical lens telescopes, each collecting light which has transited horizontal sections of the rising plume. We report on field data from Stromboli volcano, in which the entire emission rate from the volcano was measured, as well as flux signatures associated with individual crater explosions. The latter were integrated with seismic and thermal data, demonstrating correlations in both cases, and representing the first such geophysical-geochemical data corroboration on this timescale. Such a holistic e…