Search results for " Lens"

showing 10 items of 510 documents

Tear Film Surface Quality in Modern Daily Disposable Contact Lens Wear

2021

Objectives As reported previously, tear film surface quality (TFSQ) should be considered in contact lens (CL) fitting. This study followed noninvasive keratograph tear film break-up time (NIKBUT) in CL wearers for 12 months to validate its clinical utility in predicting CL performance. Methods Fifty-five subjects (M/F=17/38) aged 26±4 years were prescribed silicone hydrogel or hydrogel CLs. The study included baseline measurements without CLs; 2 visits for CL fitting and control; follow-up after 3, 6, and 12 months of CL wear; and postwear visit without CLs. Ocular Surface Disease Index (OSDI), 8-Item Contact Lens Dry Eye Questionnaire (CLDEQ-8), first and mean NIKBUT (F/M-NIKBUT), fluoresc…

medicine.medical_specialtyCorneal stainingbusiness.industrySilicone hydrogelContact Lenses HydrophilicEyeContact lensOphthalmologyCLs upper limitsTearsOphthalmologyHumansTearsMedicineDry Eye SyndromesDaily disposableOcular Surface Disease IndexbusinessOcular surfaceVision OcularEye & Contact Lens: Science & Clinical Practice
researchProduct

Implantable collamer lens with central hole: 3-year follow-up.

2018

Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain; 3School of Medicine, University of Oviedo, Oviedo, Spain Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia.Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of …

medicine.medical_specialtyDistance visual acuitygenetic structuresVisian ICLeducationEmmetropiaSpherical equivalentPhakic intraocular lensEndothelial cell count03 medical and health sciences0302 clinical medicineOphthalmologyMedicinehealth care economics and organizationsOriginal ResearchImplantable collamer lensbusiness.industryimplantable collamer lensClinical Ophthalmologyeye diseasesOphthalmologylong-term evaluation030221 ophthalmology & optometrybusinessphakic intraocular lens030217 neurology & neurosurgeryClinical ophthalmology (Auckland, N.Z.)
researchProduct

Estimation of equivalent dose to the eye lens and hands in wrist surgery using OSL dosimetry

2016

The new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) proposes reducing the limit of equivalent dose to the eye lens. For this reason, it is necessary to make estimates about received equivalent dose to the eye lens of medical staff. This study provides an alternative to dosimetry of the eye lens and hands, using dosimeters nanoDots based on optically stimulated luminescence (OSL) technology in wrist surgery procedure carried out with fluoroscopy.

medicine.medical_specialtyDosimetergenetic structuresOptically stimulated luminescencemedicine.diagnostic_testEquivalent dosebusiness.industryWrist surgeryeye diseases030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisRadiological weaponMedicineDosimetryFluoroscopyMedical physicssense organsEye lensbusinessNuclear medicine2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE)
researchProduct

Prävention des früh-postoperativen IOD-Anstiegs nach Phakoemulsifikation

2001

Purpose. To compare the ocular hypotensive effect of different antiglaucomatous eye drops. Patients and methods. This double-blind, randomized study included 119 eyes of 119 patients without other ocular pathology undergoing standardized (one surgeon, Healon) small incision cataract surgery with foldable intraocular lens implantation.The patients were assigned to one of five groups: group 1:0.25% timolol in Gelrite (extended efficacy, n=23); group 2: 2% dorzolamide (n=24); group 3: combination of 0.5% timolol plus 2% dorzolamide (n=22); group 4: brimonidine (n=26); group 5: gentamicin (control, n=24). Intraocular pressure (IOP) was measured preoperatively and at 3±1,6±1,9±1,24±3, and 48±3 h…

medicine.medical_specialtyIntraocular pressuregenetic structuresbusiness.industrymedicine.medical_treatmentBrimonidineTimololIntraocular lensPhacoemulsificationCataract surgeryeye diseasesOphthalmologyDorzolamideOphthalmologyStatistical significancemedicinebusinessmedicine.drugDer Ophthalmologe
researchProduct

Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.

2003

Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…

medicine.medical_specialtyKeratoconusRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentEye diseaseVisual AcuityIntraocular lensAstigmatismKeratoconusProsthesis DesignCataractHigh astigmatismLens Implantation IntraocularOphthalmologymedicineHumansDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Optical quality of intraocular lenses after several years in the human eye

2013

The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…

medicine.medical_specialtyMaterials sciencegenetic structuresImage qualitybusiness.industrySpectral transmissionequipment and supplieseye diseasesAtomic and Molecular Physics and OpticsOptical qualityOpticsmedicine.anatomical_structureIntraocular lensesOphthalmologymedicineHuman eyesense organsbusinessJournal of Modern Optics
researchProduct

Influence of the tear film on optical quality of the eye

1997

The optical quality of the tear film of the eye was tested by measuring the retinal image before and after the break-up time (BUT). An objective method was used based on the evaluation of the retinal image of a point test projected onto the fovea. The loss of an entire tear film would result in a decrease in the optical quality because of corneal irregularities and the formation of an irregular tear lens after the BUT. Our results confirm the expected loss both of non-contact lens wearers and contact lens wearers. Also, the fact that the optical deterioration found after the BUT is greater for contact lens wearers confirms that soft contact lens wear produces a disruption of the tears.

medicine.medical_specialtyMaterials sciencegenetic structuresbusiness.industryObjective methodGeneral Medicineeye diseasesOptical qualityRetinal imagelaw.inventionLens (optics)Contact lensOphthalmologyOpticslawOphthalmologyMerit functionmedicineTearssense organsbusinessOptometry
researchProduct

Dynamic in vitro dehydration patterns of unworn and worn silicone hydrogel contact lenses.

2008

Purpose: To evaluate the effect of wear on dynamic in vitro dehydration of silicone hydrogel (Si-Hi) contact lens (CL) using a previously described gravimetric procedure. Methods: Five different silicone hydrogel (Si-Hi) contact lenses (CL) were evaluated after being worn by patients under daily wear conditions for 15 days to 1 month. Lenses were conditioned and disinfected with a multipurpose solution after each day of wear. Lenses were left to dehydrate in an analytical balance under controlled conditions of temperature and relative humidity and the results compared with data from new lens samples of the same power and material. Several quantitative parameters were obtained and compared b…

medicine.medical_specialtyMaterials sciencemedicine.medical_treatmentBiomedical EngineeringSiliconeslaw.inventionBiomaterials03 medical and health sciences0302 clinical medicinelawmedicineRelative humidity030212 general & internal medicineDehydrationSalineSilicone hydrogelDaily wearmedicine.diseaseContact Lenses HydrophilicSurgeryContact lensLens (optics)030221 ophthalmology & optometryGravimetric analysisContact Lens SolutionsBiomedical engineeringJournal of biomedical materials research. Part B, Applied biomaterials
researchProduct

Optical analysis to predict outcomes after implantation of a double intraocular lens magnification device.

2007

Purpose To analyze the effect of different optical parameters of the eye on the outcomes of implantation of a double intraocular lens (IOL) magnification device in patients with low vision. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The eye's refraction and magnification before and after surgery were evaluated using a theoretical eye model based on paraxial optics approximation. Four parameters on which refraction and magnification are dependent were evaluated: anterior chamber depth (ACD), axial length (AL), mean keratometry (Km), and the distance between the 2 implanted IOLs. The 4 variables were analyzed separately in the first stage. Next, different combi…

medicine.medical_specialtyOptics and PhotonicsBiometrygenetic structuresAnterior Chambermedicine.medical_treatmentMagnificationVision LowIntraocular lensEyeRefraction Ocularlaw.inventionOpticsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansIn patientPhysicsLenses IntraocularKeratometerbusiness.industryParaxial approximationModels TheoreticalMagnification deviceRefractioneye diseasesSensory SystemsLow visionOphthalmologyHyperopiaTreatment OutcomeSurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct

Practical recommendations for the application of DE 59/2013

2019

The changes introduced with Council Directive 2013/59/Euratom will require European Member States adapt their regulations, procedures and equipment to the new high standards of radiation safety. These new requirements will have an impact, in particular, on the radiology community (including medical physics experts) and on industry. Relevant changes include new definitions, a new dose limit for the eye lens, non-medical imaging exposures, procedures in asymptomatic individuals, the use and regular review of diagnostic reference levels (including interventional procedures), dosimetric information in imaging systems and its transfer to the examination report, new requirements on responsibiliti…

medicine.medical_specialtyPopulationRadiation Dosage030218 nuclear medicine & medical imaging03 medical and health sciencesDose limit0302 clinical medicineOccupational ExposureLens CrystallinemedicineHumansRadiology Nuclear Medicine and imagingMedical physicsEuropean UnionEye lenseducationBSSEuropean Directive EuratomRadiodiagnostic and radiotherapeutic proceduresMedical exposureRadiation protectioneducation.field_of_studymedicine.diagnostic_testbusiness.industryMember statesInterventional radiologyGeneral MedicineRadiation ExposureReference StandardsDirective030220 oncology & carcinogenesisRadiological weaponAccidentalAsymptomatic DiseasesEmergenciesSafetyRadiologybusinessHealth PhysicsLa radiologia medica
researchProduct