Search results for " Lenses"
showing 10 items of 190 documents
Optical quality of intraocular lenses after several years in the human eye
2013
The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…
Dynamic in vitro dehydration patterns of unworn and worn silicone hydrogel contact lenses.
2008
Purpose: To evaluate the effect of wear on dynamic in vitro dehydration of silicone hydrogel (Si-Hi) contact lens (CL) using a previously described gravimetric procedure. Methods: Five different silicone hydrogel (Si-Hi) contact lenses (CL) were evaluated after being worn by patients under daily wear conditions for 15 days to 1 month. Lenses were conditioned and disinfected with a multipurpose solution after each day of wear. Lenses were left to dehydrate in an analytical balance under controlled conditions of temperature and relative humidity and the results compared with data from new lens samples of the same power and material. Several quantitative parameters were obtained and compared b…
Impact of the pupil size – central optical zone diameter relationship on visual performance in aspheric multifocal contact lenses
2020
Abstract Purpose To determine the impact of different central optical zone diameters (COZDs), obtained from pupil size, on the visual performance of presbyopic subjects fitted with centre-distance simultaneous-image multifocal contact lenses (SIMCLs). Methods Thirty-two presbyopic volunteers, between 45–58 years of age, participated in this prospective, controlled, double-blind study. Subjects were fitted with 5 centre-distance SIMCLs of variable COZD, determined from the measurement of pupil size under photopic light conditions and corresponding to 60, 70, 80, 90 and 100 % of pupil diameter. Subjects visual performance was evaluated through the measurement of distance, intermediate and nea…
Aspheric intraocular lenses enhance contrast sensitivity
2007
Evaluation of: Pandita D, Raj SM, Vasavada VA, Vasavada VA, Kazi NS, Vasavada AR. Contrast sensitivity and glare disability after implantation of AcrySof IQ natural aspherical intraocular lens: pro...
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
2017
Aim To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Methods Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Results Ana…
Proclear EP vs placebo: visual outcomes and symptoms of asthenopia in nonpresbyopes and early presbyopes
2011
Purpose: Over the past 20 years, many studies have reported the success of multifocal contact lenses (MFCLs) compared to monovision (MV), with only partial success being reported for MFCLs. Chronologically it appears there has been a gradual improvement in the performance of MFCLs. This study investigated whether this change in success is reflected in clinical practice. Method: Lens fit data collected from 2005 to 2009 by the International Contact Lens Prescribing Survey Consortium was reviewed for patients over 45 years old. A similar survey conducted from 1988 to 1989 was also reviewed and compared. Twelve published (Pubmed.gov) reports of clinical trials involving MFCLs and MV were revie…
Multifokālo kontaktlēcu lietotāju redzes asums un stereoredze
2018
Bakalaura darbs uzrakstīts uz 37 lapaspusēm, satur 10 zīmējumus, 5 tabulas un 18 literatūras avotus. Darba mērķis ir novērtēt redzes asumu un stereoredzi tuvumā un tālumā pacientiem koriģētiem ar brillēm un multifokālajām kontaktlēcām. Mūsu pētījumi parādīja, ka tāluma binokulārais redzes asums visiem pacientiem ir labs – virs 0,95. Tuvuma redzes asums pacientiem koriģētiem ar brillēm ir labāks un pacienti dod priekšroku brillēm. Tuvuma stereoredze noteikta ar Titmusa mušas testu un Titmusa apļu testu pacientiem koriģētiem ar brillēm un kontaktlēcām bija laba. Tāluma stereoredzes parametriem mēs redzam atšķirību, ar brillēm stereoredze ir labāka, bet rezultātu atšķirība nav statistiski būti…
The effect of blue-light-blocking lenses on retinal straylight
2021
Sometimes yellow-tinted lenses are recommended to help improve visual quality. As yellow lenses filter blue light, it is believed that their use could decrease the intensity of scattered light in the eye (retinal straylight). However, the results of some studies have contradicted this assumption (Van Os et al. 2017). Currently various nontinted blue-light-blocking lenses are used to protect the eyes from short-wavelength light. The objective of this study was to determine whether blue-light-blocking lenses affect the levels of retinal straylight in the eye. A straylight meter (C-Quant, Oculus) was used for retinal straylight measurements. The measurements were performed under four different…
Optical quality of hyperopic and myopic phakic intraocular lenses
2013
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…
IMI Prevention of Myopia and Its Progression
2021
The prevalence of myopia has markedly increased in East and Southeast Asia, and pathologic consequences of myopia, including myopic maculopathy and high myopia-associated optic neuropathy, are now some of the most common causes of irreversible blindness. Hence, strategies are warranted to reduce the prevalence of myopia and the progression to high myopia because this is the main modifiable risk factor for pathologic myopia. On the basis of published population-based and interventional studies, an important strategy to reduce the development of myopia is encouraging schoolchildren to spend more time outdoors. As compared with other measures, spending more time outdoors is the safest strategy…