Search results for " Limit"

showing 10 items of 1716 documents

Determination of hydroxytyrosol and tyrosol by liquid chromatography for the quality control of cosmetic products based on olive extracts

2014

An analytical method for the simultaneous determination of hydroxytyrosol and tyrosol in different types of olive extract raw materials and cosmetic cream samples has been developed. The determination was performed by liquid chromatography with UV spectrophotometric detection. Different chromatographic parameters, such as mobile phase pH and composition, oven temperature and different sample preparation variables were studied. The best chromatographic separation was obtained under the following conditions: C18 column set at 35°C and isocratic elution of a mixture ethanol: 1% acetic acid solution at pH 5 (5:95, v/v) as mobile phase pumped at 1 mL min(-1). The detection wavelength was set at …

Detection limitAnalyteChromatographyIsocratic elutionPlant ExtractsClinical BiochemistryPharmaceutical ScienceCosmeticsRepeatabilityPhenylethyl AlcoholRaw materialAnalytical ChemistryTyrosolchemistry.chemical_compoundchemistryLimit of DetectionOleaDrug DiscoveryHydroxytyrosolSpectrophotometry UltravioletSample preparationSpectroscopyChromatography LiquidJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Determination of UV filters in both soluble and particulate fractions of seawaters by dispersive liquid–liquid microextraction followed by gas chroma…

2014

An analytical method to determine the total content (i.e., not only in the soluble fraction but also in the particulate one) of eight commonly used UV filters in seawater samples is presented for the first time. Dispersive liquid-liquid microextraction (DLLME) is used as microextraction technique to pre-concentrate the target analytes before their determination by gas chromatography-mass spectrometry (GC-MS). In order to release the UV filters from the suspended particles an ultrasound treatment is performed before DLLME. The ultrasound treatment time was studied in order to achieve a quantitative lixiviation of the target analytes. The type and volume of both disperser and extraction solve…

Detection limitAnalyteChromatographyLiquid Phase MicroextractionUltraviolet RaysChemistryOsmolar ConcentrationExtraction (chemistry)Analytical chemistryRepeatabilityHydrogen-Ion ConcentrationMass spectrometryBiochemistryGas Chromatography-Mass SpectrometryAnalytical ChemistrySolventIonic strengthSolventsEnvironmental ChemistrySeawaterGas chromatography–mass spectrometrySpectroscopyAnalytica Chimica Acta
researchProduct

Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to c…

2011

Abstract The performance of a monolithic C 18 column (150 mm × 0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C 18 column (150 mm × 0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorp…

Detection limitAnalyteChromatographyMonolithic HPLC columnTriazinesCapillary actionPhenylurea CompoundsOrganic ChemistryDinitroanilineAnalytical chemistryReproducibility of ResultsContext (language use)General MedicineSolid-phase microextractionSensitivity and SpecificityBiochemistryAnalytical Chemistrychemistry.chemical_compoundOrganophosphorus CompoundschemistryChromatography columnSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Site-heterologous haptens and competitive monoclonal antibody-based immunoassays for pyrimethanil residue analysis in foodstuffs

2015

Pyrimethanil is a widely used post-harvest fungicide whose residues are commonly found in fruits and vegetables. We herein report the synthesis of two new functionalized derivatives of pyrimethanil carrying an equivalent spacer arm at different positions of the molecule. The influence of the linker tethering site on the affinity of monoclonal antibodies was shown. Moreover, the development of competitive immunoassays in different formats and with high sensitivity to the target analyte - IC50 values below 0.3μg/L - is described. Optimized assays were characterized by the determination of the limit of quantification, trueness, and precision using water-diluted QuEChERS extracts of fruits and …

Detection limitAnalyteChromatographyPesticide residuesPesticide residueChemistrymedicine.drug_classQuechersMonoclonal antibodyFood safetychemistry.chemical_compoundRegioisomeric haptensAnilinopyrimidine fungicidesmedicinePyrimethanilELISAHaptenLinkerFood Science
researchProduct

Automated high-performance liquid chromatographic determination of amphetamine in biological fluids using column-switching and on-column derivatizati…

1999

A rapid and simple liquid-chromatographic method has been developed for on-line quantification of amphetamine in biological fluids. Untreated samples (20 μL) are injected directly into the chromatographic system and purified on a 20 mm×2.1 mm i.d. pre-column packed with 30 μm Hypersil C18 stationary phase. After clean-up the analyte is transferred to the analytical column (125 mm×4 mm i.d., 5 μm LiChrospher 100 RP18) for derivatization and separation using a mixture of acetonitrile and the derivatization reagent (o-phthaldialdehyde andN-acetyl-L-cysteine) as the mobile phase. The experimental conditions for on-line derivatization and resolution of the amphetamine have been optimized, and th…

Detection limitAnalyteChromatographyResolution (mass spectrometry)Organic ChemistryClinical BiochemistryAnalytical chemistryBiochemistryHigh-performance liquid chromatographyFluorescence spectroscopyAnalytical Chemistrychemistry.chemical_compoundchemistryReagentDerivatizationQuantitative analysis (chemistry)Chromatographia
researchProduct

Improving analysis of apolar organic compounds by the use of a capillary titania-based column: Application to the direct determination of faecal ster…

2010

This article reports a new procedure for the direct determination of faecal sterols coprostanol and cholesterol in wastewater samples as tracers of human sewage contamination. The method combines in-tube solid-phase microextraction (IT-SPME) for analyte enrichment and capillary liquid chromatography (LC) for separation with diode array detection for identification and quantification. A titania-based polymeric capillary column and a conventional octadecyl silica (ODS) capillary column were evaluated and compared for their ability to separate the analytes. The titania-based column allowed the separation of the analytes in much shorter chromatographic times and with better chromatographic prof…

Detection limitAnalyteChromatographySewageChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineReversed-phase chromatographySolid-phase microextractionBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryCoprostanolCholestanolchemistry.chemical_compoundFecesCholesterolWastewaterHumansSample preparationSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Development of a fully automated sequential injection solid-phase extraction procedure coupled to liquid chromatography to determine free 2-hydroxy-4…

2010

Abstract 2-Hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid, commonly known as benzophenone-3 (BZ3) and benzophenone-4 (BZ4), respectively, are substances widely used as UV filters in cosmetic products in order to absorb UV radiation and protect human skin from direct exposure to the deleterious wavelengths of sunlight. As with other UV filters, there is evidence of their percutaneous absorption. This work describes an analytical method developed to determine trace levels of free BZ3 and BZ4 in human urine. The methodology is based on a solid-phase extraction (SPE) procedure for clean-up and pre-concentration, followed by the monitoring of the UV filters by…

Detection limitAnalyteChromatographymedicine.diagnostic_testChemistryElutionSolid Phase ExtractionExtraction (chemistry)TemperatureHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryBenzophenonesSpectrophotometryStandard additionmedicineHumansEnvironmental ChemistrySpectrophotometry UltravioletSolid phase extractionSelectivitySunscreening AgentsChromatography High Pressure LiquidSpectroscopyAnalytica Chimica Acta
researchProduct

Spectrophotometric determination of phenols in water samples by the GHPSAM method

2001

Abstract The generalized H-point standard-additions method (GHPSAM) is proposed in order to obtain the phenol concentration in water samples when the matrix is completely unknown. The procedure involves solid-phase extraction in BondElut PPL cartridges and data handling of the UV-visible spectrophotometry measurements. The spectral regions where the unknown interferent behaviour can be considered as linear are found and the analyte concentration free from bias error is estimated. The percentages of recovery of phenols in spiked samples were similar to those obtained by HPLC. Cresols or chlorophenols can be also determined in real samples by this method. The concentration range tested was 0.…

Detection limitAnalyteChromatographymedicine.diagnostic_testChemistryHealth Toxicology and MutagenesisExtraction (chemistry)Public Health Environmental and Occupational HealthAnalytical chemistrySoil SciencePollutionHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)chemistry.chemical_compoundSpectrophotometrymedicineEnvironmental ChemistryPhenolSolid phase extractionWaste Management and DisposalWater Science and Technology
researchProduct

A sequential-injection system for spectrophotometric determination of p -aminobenzoic acid in sunscreens.

2002

A sequential injection method is proposed for spectrophotometric determination of p-aminobenzoic acid (PABA) in cosmetic formulations. The method is based on diazotization of the analyte, coupling with 8-hydroxyquinoline, and the subsequent formation of a colored product. The experimental conditions used (coupling reagent, sandwich arrangement, volumes aspirated, propulsion flow rate, reaction coil length) were studied. Response of the sequential injection method were linearly dependent on concentrations up to 25 micro g mL(-1) and the detection limit was 2 micro g mL(-1). Throughput was 51 measurements per hour and a complete cycle, including three measurement per sample and a washing step…

Detection limitAnalyteChromatographymedicine.diagnostic_testSpectrum AnalysisColorReproducibility of ResultsSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistrySpectrophotometrymedicine4-Aminobenzoic acidAminobenzoic acidSelectivity4-Aminobenzoic AcidAzo CompoundsSunscreening AgentsQuantitative analysis (chemistry)Analytical and Bioanalytical Chemistry
researchProduct

Exploring hand-portable nano-liquid chromatography for in place water analysis: Determination of trimethylxanthines as a use case.

2020

Abstract Analytical performance and optimization of figures of merit of a portable nano liquid chromatograph (NanoLC) with UV detection at 255 nm have been established for in place analysis. Methylxanthines: caffeine, theophylline and theobromine were selected as target analytes. A fast lab method based on IT-SPME coupled on line with capillary liquid chromatograph (CapLC) with diode array detection (DAD) was employed for comparative studies. IT-SPME and solid phase extraction were coupled off-line to NanoLC for improving instrumental parameters, mainly detection capacity and selectivity. IT-SPME or SPE/portable NanoLC based methods were superior in terms of chromatographic resolution and o…

Detection limitAnalyteEnvironmental EngineeringChromatographyMaterials science010504 meteorology & atmospheric sciencesResolution (mass spectrometry)Capillary action010501 environmental sciences01 natural sciencesPollutionDiode arrayNano liquid chromatographyTheophyllineLimit of DetectionCaffeineEnvironmental ChemistryFigure of meritSolid phase extractionWaste Management and DisposalChromatography High Pressure LiquidSolid Phase MicroextractionWater Pollutants Chemical0105 earth and related environmental sciencesChromatography LiquidThe Science of the total environment
researchProduct