Search results for " MRI."
showing 10 items of 211 documents
Peliosis hepatis: spectrum of imaging findings
2006
OBJECTIVE. It is important to recognize the imaging characteristics of peliosis hepatis because peliotic lesions may mimic several different types of focal hepatic lesions CONCLUSION. We illustrate the spectrum of imaging findings of peliosis hepatis, including sonography, CT, MR, and angiography.
Outcome Analysis and Rational Management of Enhancing Lesions Incidentally Detected on Contrast-Enhanced MRI of the Breast
2003
The purpose of our study was to assess the prevalence, characteristics, and clinical consequence of incidentally detected enhancing lesions on MRI of the breast. SUBJECTS AND METHODS. MRI of the breast (1.0-T scanner, dynamic gadolinium-enhanced T1-weighted three-dimensional gradient-echo sequence, double breast coil) was performed on 1273 women for different indications. Enhancing incidental lesions were defined as enhancing lesions on MRIs that were not expected from findings on the previous conventional imaging. They were classified in five assessment categories using a scoring system based on morphologic and kinetic enhancement characteristics. Detection of enhancing incidental lesions …
Fuzzy C-Means Segmentation on Brain MR Slices Corrupted by RF-Inhomogeneity
2007
Brain MR Images corrupted by RF-Inhomogeneity exhibit brightness variations in such a way that a standard Fuzzy C-Means (fcm) segmentation algorithm fails. As a consequence, modified versions of the algorithm can be found in literature, which take into account the artifact. In this work we show that the application of a suitable pre-processing algorithm, already presented by the authors, followed by a standard fcm segmentation achieves good results also. The experimental results ones are compared with those obtained using SPM5, which can be considered the state of the art algorithm oriented to brain segmentation and bias removal.
Illumination Correction on MR Images
2006
Objective. An important artifact corrupting Magnetic Resonance Images is the rf inhomogeneity, also called bias artifact. This anomaly produces an abnormal illumination fluctuation on the image, due to variations of the device magnetic field. This artifact is particularly strong on images acquired with a device specialized on upper and lower limbs due to their coil configuration. A method based on homomorphic filtering aimed to suppress this artifact was proposed by Guillemaud. This filter has two faults: it doesnt provide an indication about the cutoff frequency (cf) and introduces another illumination artifact on the edges of the foreground. This work is an improvement to this method because i…
Volumetric Bias Correction
2007
This paper presents a method to suppress the bias artifact, also known as RF-inhomogeneity, in Magnetic Resonance Imaging (MRI). This artifact produces illumination variations due to magnetic field fluctuations of the device. In the latest years many works have been devoted to face this problem. In this work we present the 3D version of a new approach to bias correction, which is called Exponential Entropy Driven Homomorphic Unsharp Masking (E2D-HUM). This technique has been already presented by some of the authors for the 2D case only. The description of the whole method is detailed, and some experimental results are reported.
Confronto TAC – MRI per lo studio della cinetica di assorbimento dell’acqua in materiali lapidei
2007
Vengono messe a confronto due tecniche, la Risonanza Magnetica (MRI) e la tomografia assiale computerizzata (TAC), per ottenere informazioni quantitative sulla cinetica di assorbimento dell’acqua in sezioni interne di materiali lapidei. Entrambe le tecniche permettono di studiare adeguatamente il fenomeno. Nel caso in cui si formi un fronte di bagnamento, come per la Pietra di Lecce, l’analisi delle immagini consente di determinare in modo quantitativo l’altezza di risalita in funzione del tempo ed i dati possono essere interpretati alla luce del modello di Washburn per l’assorbimento capillare. Nel caso in cui il fronte non si formi, come per campioni di biocalcareite provenienti da una ca…
Musical expertise modulates functional connectivity of limbic regions during continuous music listening.
2015
Music is known to be an important facet of all human cultures (Merriam, 1964). Listening to music in order to influence moods, evoke strong emotions, and derive pleasure is becoming increasingly common, especially in this day and age when access to music is easy and quick. In recent years, exploring the neural correlates of musical emotions has attracted the attention of neuroscientists (Brattico & Pearce, 2013; Koelsch, Fritz, v. Cramon, Muller, & Friederici, 2006). However, the majority of these studies have not accounted for the effect of musical expertise, despite increasing evidence of structural and functional differences between musicians and nonmusicians, particularly in the regions…
Cinetica di assorbimento dell’acqua tramite NMR Imaging per la valutazione della efficacia di trattamenti idrorepellenti
2007
L'efficacia dei trattamenti normalmente impiegati per proteggere e/o consolidare materiali lapidei può essere valutata mediante la tecnica di imaging a risonanza magnetica nucleare (MRI), che consente di studiare in modo quantitativo, non invasivo, non distruttivo, la cinetica di assorbimento capillare dell'acqua. In campioni omogenei (Pietra di Lecce) si forma un fronte piatto (con una discontinuità netta alla scala di misura) e la tecnica MRI permette di seguire la cinetica in quanto consente di misurare, in funzione del tempo, l'altezza raggiunta da tale fronte in qualunque sezione interna del campione. Vengono confrontati i risultati ottenuti sullo stesso litotipo utilizzando due divers…
Evaluation of proton MR spectroscopy at 3 Tesla without endorectal coil in patients with a localized prostate cancer treated with exclusive radiother…
2011
Prostate cancer is the most frequent tumour affecting the male population. When the prostate is not removed and is treated with radiation therapy, PSA slowly decreases over time to reach its nadir, even sometimes 18 to 24 months after the completion of radiation therapy without combined androgen suppression therapy. When combined with hormones, PSA falls abruptely with no possibility to perceive the impact of either hormones or radiation effects on PSA.The optimal value of PSA that should be reached after radiation therapy (nadir) and time to this nadir are still unclear.Even when a satisfactory value of the PSA nadir is reached, on-going variations of the PSA and its “bounce” effects, whic…
Glenoid bone loss in anterior shoulder dislocation: a multicentric study to assess the most reliable imaging method
2022
Purpose: The aim of this multicentric study was to assess which imaging method has the best inter-reader agreement for glenoid bone loss quantification in anterior shoulder instability. A further aim was to calculate the inter-method agreement comparing bilateral CT with unilateral CT and MR arthrography (MRA) with CT measurements. Finally, calculations were carried out to find the least time-consuming method. Method: A retrospective evaluation was performed by 9 readers (or pairs of readers) on a consecutive series of 110 patients with MRA and bilateral shoulder CT. Each reader was asked to calculate the glenoid bone loss of all patients using the following methods: best fit circle area on…